Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 188(1): 1, 2021 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-33386503

RESUMO

Polymelamine formaldehyde/graphene oxide (PMF/GO) nanocomposite was used, for the first time, to study the ultrasensitive and selective electrochemical detection of oxycodone (OXC). The successful characterization of PMF/GO was verified based on scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared (FT-IR), X-ray diffraction (XRD), energy-dispersive spectroscopy (EDS), and Raman spectroscopy. The modified GCE (PMF/GO-GCE) proved its electrocatalytic effect on OXC determination according to cyclic, linear sweep, and differential pulse voltammetry (CV, LSV, and DPV) and electrochemical impedance spectroscopy (EIS) studies. The developed sensor under optimal conditions offered a linear relationship in a limited range of  0.01 to 45 µmol L-1 with the limit of detection (LOD) of 2.0 nmol L-1. The proposed PMF/GO-GCE sensor was effectively employed for the OXC detection in human urine and serum samples. Graphical abstract.


Assuntos
Grafite/química , Nanocompostos/química , Oxicodona/sangue , Oxicodona/urina , Polímeros/química , Triazinas/química , Carbono/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Humanos , Limite de Detecção , Oxirredução , Oxicodona/química , Reprodutibilidade dos Testes
2.
Mater Sci Eng C Mater Biol Appl ; 60: 276-284, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26706531

RESUMO

Here, cobalt ferrite nanohybrid decorated on exfoliated graphene oxide (CoFe2O4/EGO) was synthesized. The nanohybrid was characterized by different methods such as X-ray diffraction spectroscopy, scanning electron microscopy, energy dispersive X-ray diffraction microanalysis, transmission electron microscopy, FT-IR, Raman spectroscopy and electrochemical methods. The CoFe2O4/EGO nanohybrid was used to modify glassy carbon electrode (GCE). The voltammetric investigations showed that CoFe2O4/EGO nanohybrid has synergetic effect towards the electro-reduction of H2O2 and electro-oxidation of nicotinamide adenine dinucleotide (NADH). Rotating disk chronoamperometry was used for their quantitative analysis. The calibration curves were observed in the range of 0.50 to 100.0 µmol L(-1) NADH and 0.9 to 900.0 µmol L(-1) H2O2 with detections limit of 0.38 and 0.54 µmol L(-1), respectively. The repeatability, reproducibility and selectivity of the electrochemical sensor for analysis of the analytes were studied. The new electrochemical sensor was successfully applied for the determination of NADH and H2O2 in real samples with satisfactory results.


Assuntos
Cobalto/química , Compostos Férricos/química , Grafite/química , Peróxido de Hidrogênio/química , Nanopartículas Metálicas/química , NAD/química , Nanopartículas Metálicas/análise , NAD/análise , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...