Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
CMAJ ; 185(4): 297-305, 2013 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-23359039

RESUMO

BACKGROUND: Most patients with type 1 diabetes do not achieve their glycemic targets. We aimed to assess the efficacy of glucose-responsive insulin and glucagon closed-loop delivery for controlling glucose levels in adults with type 1 diabetes. METHODS: We conducted a randomized crossover trial involving 15 adults with type 1 diabetes, comparing standard insulin-pump therapy with dual-hormone, closed-loop delivery. Patients were admitted twice to a clinical research facility and received, in random order, both treatments. Each 15-hour visit (from 1600 to 0700) included an evening exercise session, followed by a medium-sized meal, a bedtime snack and an overnight stay. During visits that involved closed-loop delivery, basal insulin and glucagon miniboluses were delivered according to recommendations based on glucose sensor readings and a predictive dosing algorithm at 10-minute intervals. During visits involving standard insulin-pump therapy (control visits), patients used conventional treatment. RESULTS: Dual-hormone closed-loop delivery increased the percentage of time for which patients' plasma glucose levels were in the target range (median 70.7% [interquartile range (IQR) 46.1%-88.4%] for closed-loop delivery v. 57.3% [IQR 25.2%-71.8%] for control, p = 0.003) and decreased the percentage of time for which plasma glucose levels were in the low range (bottom of target range [< 4.0 mmol/L], 0.0% [IQR 0.0%-3.0%] for closed-loop delivery v. 10.2% [IQR 0.0%-13.0%] for control, p = 0.01; hypoglycemia threshold [< 3.3 mmol/L], 0.0% [IQR 0.0%-0.0%] for closed-loop delivery v. 2.8% [IQR 0.0%-5.9%] for control, p = 0.006). Eight participants (53%) had at least 1 hypoglycemic event (plasma glucose < 3.0 mmol/L) during standard treatment, compared with just 1 participant (7%) during closed-loop treatment (p = 0.02). INTERPRETATION: Dual-hormone, closed-loop delivery guided by advanced algorithms improved short-term glucose control and reduced the risk of hypoglycemia in a group of 15 adults with type 1 diabetes. TRIAL REGISTRATION: ClinicalTrials.gov, no. NCT01297946.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/administração & dosagem , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Insulina Aspart/administração & dosagem , Pâncreas Artificial , Adulto , Algoritmos , Biomarcadores/sangue , Glicemia/metabolismo , Estudos Cross-Over , Técnicas de Apoio para a Decisão , Diabetes Mellitus Tipo 1/sangue , Esquema de Medicação , Quimioterapia Combinada , Feminino , Glucagon/uso terapêutico , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/uso terapêutico , Bombas de Infusão Implantáveis , Insulina Aspart/efeitos adversos , Insulina Aspart/uso terapêutico , Sistemas de Infusão de Insulina , Masculino , Análise de Regressão , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...