1.
Med Tekh ; (6): 23-6, 2005.
Artigo em Russo | MEDLINE | ID: mdl-16491658

RESUMO

In the new ventilator Avenir-221 P modern lines of development of ventilation support in intensive therapy of adults and children are implemented. The capacities of the ventilator are successfully combined with its technical decisions which include microprocessor parametrical controlling, programming-controlled electric drive, an information saturation, intuitively clear control system, protection against interruption of power supply sources and oxygen feeding falls. A set of functional characteristics (modes VCV, PCV, Ass/Contr, PSV, SIMV, PEEP, Sigh, etc.) in combination with an original design make the device the most accessible and promising for application in intensive care and resuscitation units of a wide network of Russian hospitals and clinics. The ventilator Avenir-221 P has passed all required tests and is presently commercially available.


Assuntos
Respiração Artificial/instrumentação , Respiração Artificial/tendências , Adolescente , Adulto , Peso Corporal , Desenho de Equipamento , Humanos , Recém-Nascido , Monitorização Fisiológica , Federação Russa
2.
Med Tekh ; (4): 3-11, 2003.
Artigo em Russo | MEDLINE | ID: mdl-14518108

RESUMO

The requirements applicable to the canal of the artificial ventilation of the lungs (AVL), volume measuring and to methods of appropriate monitoring based on GOST R ISO 10651.1-99 "Medical equipment of artificial ventilation of the lungs. Part 1. Technical requirements" (now valid). The recommendations on the testing methods and means and, in particular, on modeling the stretching properties and resistance of pulmonary phantoms are motivated. The influence of the internal stretching properties of AVL equipment and of the inertia system's specificity, comprising an apparatus and patient's respiratory organs, produced on the apparatus characteristics and functional curves (gas flow velocity, respiratory volume as well as pressure in the lungs and at the apparatus outlet) is analyzed.


Assuntos
Respiração Artificial/instrumentação , Ventiladores Mecânicos/normas , Adolescente , Adulto , Fatores Etários , Resistência das Vias Respiratórias , Criança , Humanos , Recém-Nascido , Complacência Pulmonar , Teste de Materiais , Modelos Biológicos , Modelos Teóricos , Troca Gasosa Pulmonar , Respiração , Mecânica Respiratória/fisiologia