Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS Negl Trop Dis ; 16(2): e0010172, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35143500

RESUMO

Burkholderia pseudomallei is a soil-dwelling bacterium endemic to Southeast Asia and northern Australia that causes the disease, melioidosis. Although the global genomic diversity of clinical B. pseudomallei isolates has been investigated, there is limited understanding of its genomic diversity across small geographic scales, especially in soil. In this study, we obtained 288 B. pseudomallei isolates from a single soil sample (~100g; intensive site 2, INT2) collected at a depth of 30cm from a site in Ubon Ratchathani Province, Thailand. We sequenced the genomes of 169 of these isolates that represent 7 distinct sequence types (STs), including a new ST (ST1820), based on multi-locus sequence typing (MLST) analysis. A core genome SNP phylogeny demonstrated that all identified STs share a recent common ancestor that diverged an estimated 796-1260 years ago. A pan-genomics analysis demonstrated recombination between clades and intra-MLST phylogenetic and gene differences. To identify potential differential virulence between STs, groups of BALB/c mice (5 mice/isolate) were challenged via subcutaneous injection (500 CFUs) with 30 INT2 isolates representing 5 different STs; over the 21-day experiment, eight isolates killed all mice, 2 isolates killed an intermediate number of mice (1-2), and 20 isolates killed no mice. Although the virulence results were largely stratified by ST, one virulent isolate and six attenuated isolates were from the same ST (ST1005), suggesting that variably conserved genomic regions may contribute to virulence. Genomes from the animal-challenged isolates were subjected to a bacterial genome-wide association study to identify genomic regions associated with differential virulence. One associated region is a unique variant of Hcp1, a component of the type VI secretion system, which may result in attenuation. The results of this study have implications for comprehensive sampling strategies, environmental exposure risk assessment, and understanding recombination and differential virulence in B. pseudomallei.


Assuntos
Burkholderia pseudomallei/isolamento & purificação , Burkholderia pseudomallei/patogenicidade , Melioidose/microbiologia , Filogenia , Microbiologia do Solo , Animais , Burkholderia pseudomallei/classificação , Burkholderia pseudomallei/genética , Feminino , Genoma Bacteriano , Genômica , Humanos , Camundongos Endogâmicos BALB C , Tipagem de Sequências Multilocus , Tailândia , Virulência
2.
Int J Pharm ; 565: 9-19, 2019 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-31047995

RESUMO

Microneedle technology offers a viable means of delivering biologically active pharmaceutical agents across the skin in a minimally invasive and virtually pain free manner. Previous work detailed the first successful transdermal delivery of a model peptide drug, polymyxin b, utilising a dissolving polymer-based microneedle system. The focus of this study was to examine the ability of a dissolving microneedle system to deliver a range of peptides of different sizes and properties. Analogue versions of 2 existing therapeutic peptides; pentagastrin and sincalide, were synthesised utilising Fmoc based solid phase peptide synthesis (SPPS) chemistry techniques and once successfully synthesised and purified, the peptide analogues were characterised using LC-MS. The peptide analogues were then incorporated into PVP/trehalose microneedle formulations. Skin permeation testing, in addition to skin penetration testing, was carried out to determine the effectiveness of the microneedle system to deliver the peptide analogues through porcine skin. The results obtained from these studies were then compared with the permeation results obtained utilising polymyxin B as the peptide drug cargo to evaluate the PVP/trehalose microneedle system's suitability to successfully deliver therapeutic peptides. Results indicated that the microneedle system successfully systemically delivered a higher overall percentage of the encapsulated peptides at an initially faster rate than peptide loaded control discs and in therapeutically relevant concentrations.


Assuntos
Sistemas de Liberação de Medicamentos , Agulhas , Pentagastrina/administração & dosagem , Sincalida/administração & dosagem , Administração Cutânea , Animais , Feminino , Masculino , Microinjeções , Polimixina B/administração & dosagem , Pele/metabolismo , Absorção Cutânea , Solubilidade , Suínos
3.
Anal Chem ; 88(23): 11486-11490, 2016 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-27934114

RESUMO

The study reports the use of extended gate field-effect transistors (FET) for the label-free and sensitive detection of prostate cancer (PCa) biomarkers in human plasma. The approach integrates for the first time hybrid synthetic receptors comprising of highly selective aptamer-lined pockets (apta-MIP) with FETs for sensitive detection of prostate specific antigen (PSA) at clinically relevant concentrations. The hybrid synthetic receptors were constructed by immobilizing an aptamer-PSA complex on gold and subjecting it to 13 cycles of dopamine electropolymerization. The polymerization resulted in the creation of highly selective polymeric cavities that retained the ability to recognize PSA post removal of the protein. The hybrid synthetic receptors were subsequently used in an extended gate FET setup for electrochemical detection of PSA. The sensor was reported to have a limit of detection of 0.1 pg/mL with a linear detection range from 0.1 pg/mL to 1 ng/mL PSA. Detection of 1-10 pg/mL PSA was also achieved in diluted human plasma. The present apta-MIP sensor developed in conjunction with FET devices demonstrates the potential for clinical application of synthetic hybrid receptors for the detection of clinically relevant biomarkers in complex samples.


Assuntos
Técnicas Biossensoriais , Ouro/química , Óxidos/química , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Receptores Artificiais/química , Aptâmeros de Nucleotídeos/sangue , Humanos , Masculino , Receptores Artificiais/síntese química , Semicondutores , Transistores Eletrônicos
4.
Eur J Pharm Biopharm ; 107: 1-6, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27373753

RESUMO

Computerized tomography scan (CT scan) imaging and finite element analysis were employed to investigate how the geometric composition of microneedles affects their mechanical strength and penetration characteristics. Simulations of microneedle arrays, comprising triangular, square and hexagonal microneedle base, revealed a linear dependence of the mechanical strength to the number of vertices in the polygon base. A laser-enabled, micromoulding technique was then used to fabricate 3×3 microneedle arrays, each individual microneedle having triangular, square or hexagonal base geometries. Their penetration characteristics into ex-vivo porcine skin, were investigated for the first time by CT scan imaging. This revealed greater penetration depths for the triangular and square-based microneedles, demonstrating CT scan as a powerful and reliable technique for studying microneedle skin penetration.


Assuntos
Agulhas , Pele/metabolismo , Tomografia Computadorizada por Raios X , Animais , Análise de Elementos Finitos , Suínos
5.
Biosens Bioelectron ; 75: 188-95, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26318788

RESUMO

This study reports the design and evaluation of a new synthetic receptor sensor based on the amalgamation of biomolecular recognition elements and molecular imprinting to overcome some of the challenges faced by conventional protein imprinting. A thiolated DNA aptamer with established affinity for prostate specific antigen (PSA) was complexed with PSA prior to being immobilised on the surface of a gold electrode. Controlled electropolymerisation of dopamine around the complex served to both entrap the complex, holding the aptamer in, or near to, it's binding conformation, and to localise the PSA binding sites at the sensor surface. Following removal of PSA, it was proposed that the molecularly imprinted polymer (MIP) cavity would act synergistically with the embedded aptamer to form a hybrid receptor (apta-MIP), displaying recognition properties superior to that of aptamer alone. Electrochemical impedance spectroscopy (EIS) was used to evaluate subsequent rebinding of PSA to the apta-MIP surface. The apta-MIP sensor showed high sensitivity with a linear response from 100pg/ml to 100ng/ml of PSA and a limit of detection of 1pg/ml, which was three-fold higher than aptamer alone sensor for PSA. Furthermore, the sensor demonstrated low cross-reactivity with a homologous protein (human Kallikrein 2) and low response to human serum albumin (HSA), suggesting possible resilience to the non-specific binding of serum proteins.


Assuntos
Técnicas Biossensoriais , Calicreínas/sangue , Impressão Molecular , Antígeno Prostático Específico/sangue , Aptâmeros de Nucleotídeos/química , Espectroscopia Dielétrica , Ouro/química , Humanos , Masculino , Polímeros/química , Albumina Sérica/isolamento & purificação , Calicreínas Teciduais/isolamento & purificação
6.
J Urol ; 195(3): 763-70, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26478446

RESUMO

PURPOSE: We compared the relative permeability of upper urinary tract and bladder urothelium to mitomycin C. MATERIALS AND METHODS: Ex vivo porcine bladder, ureters and kidneys were dissected out and filled with 1 mg ml(-1) mitomycin C. At 60 minutes the organs were emptied and excised tissue samples were sectioned parallel to the urothelium. Sectioned tissue was homogenized and extracted mitomycin C was quantified. Transurothelial permeation across the different urothelia was calculated by normalizing the total amount of drug extracted to the surface area of the tissue sample. Average mitomycin C concentrations at different tissue depths (concentration-depth profiles) were calculated by dividing the total amount of drug recovered by the total weight of tissue. RESULTS: Mitomycin C permeation across the ureteral urothelium was significantly greater than across the bladder and renal pelvis urothelium (9.07 vs 0.94 and 3.61 µg cm(-2), respectively). Concentrations of mitomycin C in the ureter and kidney were markedly higher than those achieved in the bladder at all tissue depths. Average urothelial mitomycin C concentrations were greater than 6.5-fold higher in the ureter and renal pelvis than in the bladder. CONCLUSIONS: To our knowledge we report for the first time that the upper urinary tract and bladder show differing permeability to a single drug. Ex vivo porcine ureter is significantly more permeable to mitomycin C than bladder urothelium and consequently higher mitomycin C tissue concentrations can be achieved after topical application. Data in this study correlate with the theory that mammalian upper tract urothelium represents a different cell lineage than that of the bladder and it is innately more permeable to mitomycin C.


Assuntos
Mitomicina/farmacocinética , Ureter/metabolismo , Bexiga Urinária/metabolismo , Urotélio/metabolismo , Animais , Técnicas In Vitro , Permeabilidade , Suínos
7.
Eur Endocrinol ; 12(2): 79-84, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29632592

RESUMO

Background: Patch pumps are a relatively new method of Insulin delivery. This study explores the accuracy of patch-pumps by reporting on comparative pulse-accuracy study of two patch pumps. Methods: The accuracy of two patch pumps (Cellnovo, [Cellnovo Ltd., Swansea, UK] and OmniPod® [Ypsomed Ltd, Escrick, UK]) was evaluated micro-gravimetrically. Pulse accuracy was analysed by comparing single and time-averaged pulses for each device. Results: Single-pulses outside accuracy thresholds ±5%, ±10%, ±15%, ±20%, ±25% and ±30% were: Cellnovo; 79.6%, 55.6%, 35.0%, 19.9%, 9.7% and 4.3%; OmniPod; 86.2%, 71.6%, 57.4%, 45.5%, 35.2% and 25.4%. For 10, 20 and 40 pulse-windows mean values outside ±15% accuracy level were: Cellnovo; 7.3%, 1.5% and 0.4%, OmniPod; 37.6%, 31.8% and 25.9. Conclusions: This study showed that not all patch pumps are the same. The pumping mechanisms employed in these pumps play a significant role in the accuracy and precision of such devices.

8.
J Pharm Sci ; 104(7): 2233-40, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25989054

RESUMO

Intravesical oxybutynin is highly effective in the treatment of overactive bladder. Traditionally the mechanism of action was explained by antagonism of muscarinic receptors located in the detrusor, however evidence now suggests antimuscarinics may elicit their effect by modifying afferent pathways in the mucosal region. This study aimed to investigate the bladder wall distribution of oxybutynin in an ex vivo setting providing tissue - layer specific concentrations of drug achieved after intravesical delivery. Whole ex vivo porcine bladders were intravesically instilled with 0.167 mg mL(-1) oxybutynin solution. After 60 min, tissue samples were excised, serially sectioned parallel to the urothelial surface and extracted drug quantified. Drug distribution into the urothelium, lamina propria and detrusor was determined. Oxybutynin permeated into the bladder wall at a higher rate than other drugs previously investigated (apparent transurothelial Kp = 1.36 × 10(-5) cm s(-1) ). After 60 min intravesical instillation, concentrations achieved in the urothelium (298.69 µg g(-1) ) and lamina propria (43.65 µg g(-1) ) but not the detrusor (0.93 µg g(-1) ) were greater than reported IC50 values for oxybutynin. This work adds to the increasing body of evidence suggesting antimuscarinics elicit their effects via mechanisms other than direct inhibition of detrusor contraction.


Assuntos
Ácidos Mandélicos/administração & dosagem , Ácidos Mandélicos/metabolismo , Músculos/metabolismo , Bexiga Urinária Hiperativa/metabolismo , Bexiga Urinária/metabolismo , Administração Intravesical , Animais , Mucosa/metabolismo , Antagonistas Muscarínicos/administração & dosagem , Antagonistas Muscarínicos/metabolismo , Suínos , Urotélio/metabolismo
9.
Eur J Pharm Biopharm ; 89: 224-31, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25481031

RESUMO

Dissolving microneedles are especially attractive for transdermal drug delivery as they are associated with improved patient compliance and safety. Furthermore, microneedles made of sugars offer the added benefit of biomolecule stabilisation making them ideal candidates for delivering biological agents such as proteins, peptides and nucleic acids. In this study, we performed experimental and finite element analyses to study the mechanical properties of sugar microneedles and evaluate the effect of sugar composition on microneedle ability to penetrate and deliver drug to the skin. Results showed that microneedles made of carboxymethylcellulose/maltose are superior to those made of carboxymethylcellulose/trehalose and carboxymethylcellulose/sucrose in terms of mechanical strength and the ability to deliver drug. Buckling was predicted to be the main mode of microneedle failure and the order of buckling was positively correlated to the Young's modulus values of the sugar constituents of each microneedle.


Assuntos
Materiais Biocompatíveis/química , Carboximetilcelulose Sódica/química , Dissacarídeos/química , Preparações Farmacêuticas/administração & dosagem , Pele/metabolismo , Administração Cutânea , Animais , Sistemas de Liberação de Medicamentos/métodos , Análise de Elementos Finitos , Microinjeções/métodos , Agulhas , Suínos
10.
Mol Pharm ; 11(3): 673-82, 2014 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-24460452

RESUMO

Transurothelial drug delivery continues to be an attractive treatment option for a range of urological conditions; however, dosing regimens remain largely empirical. Recently, intravesical delivery of the nonsteroidal anti-inflammatory ketorolac has been shown to significantly reduce ureteral stent-related pain. While this latest development provides an opportunity for advancing the management of stent-related pain, clinical translation will undoubtedly require an understanding of the rate and extent of delivery of ketorolac into the bladder wall. Using an ex vivo porcine model, we evaluate the urothelial permeability and bladder wall distribution of ketorolac. The subsequent application of a pharmacokinetic (PK) model enables prediction of concentrations achieved in vivo. Ketorolac was applied to the urothelium and a transurothelial permeability coefficient (Kp) calculated. Relative drug distribution into the bladder wall after 90 min was determined. Ketorolac was able to permeate the urothelium (Kp = 2.63 × 10(-6) cm s(-1)), and after 90 min average concentrations of 400, 141 and 21 µg g(-1) were achieved in the urothelium, lamina propria and detrusor respectively. An average concentration of 87 µg g(-1) was achieved across the whole bladder wall. PK simulations (STELLA) were then carried out, using ex vivo values for Kp and muscle/saline partition coefficient (providing an estimation of vascular clearance), to predict 90 min in vivo ketorolac tissue concentrations. When dilution of the drug solution with urine and vascular clearance were taken into account, a reduced ketorolac concentration of 37 µg g(-1) across the whole bladder wall was predicted. These studies reveal crucial information about the urothelium's permeability to agents such as ketorolac and the concentrations achievable in the bladder wall. It would appear that levels of ketorolac delivered to the bladder wall intravesically would be sufficient to provide an anti-inflammatory effect. The combination of such ex vivo data and PK modeling provides an insight into the likelihood of achieving clinically relevant concentrations of drug following intravesical administration.


Assuntos
Anti-Inflamatórios não Esteroides/farmacocinética , Permeabilidade da Membrana Celular/efeitos dos fármacos , Cetorolaco/farmacocinética , Bexiga Urinária/efeitos dos fármacos , Bexiga Urinária/metabolismo , Administração Intravesical , Animais , Anti-Inflamatórios não Esteroides/administração & dosagem , Simulação por Computador , Sistemas de Liberação de Medicamentos , Cetorolaco/administração & dosagem , Cinética , Suínos , Distribuição Tecidual
11.
Nanomaterials (Basel) ; 3(1): 192-203, 2013 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-28348330

RESUMO

This study evaluates the effectiveness of vapour-phase deposition for creating sub-monolayer coverage of aminopropyl triethoxysilane (APTES) on silicon in order to exert control over subsequent gold nanoparticle deposition. Surface coverage was evaluated indirectly by observing the extent to which gold nanoparticles (AuNPs) deposited onto the modified silicon surface. By varying the distance of the silicon wafer from the APTES source and concentration of APTES in the evaporating media, control over subsequent gold nanoparticle deposition was achievable to an extent. Fine control over AuNP deposition (AuNPs/µm²) however, was best achieved by adjusting the ionic concentration of the AuNP-depositing solution. Furthermore it was demonstrated that although APTES was fully removed from the silicon surface following four hours incubation in water, the gold nanoparticle-amino surface complex was stable under the same conditions. Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) were used to study these affects.

12.
J Mol Recognit ; 24(6): 1115-22, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22038818

RESUMO

A contributing factor to the labored advance of molecularly imprinting as a viable commercial solution to molecular recognition needs is the absence of a standard and robust method for assessing and reporting on molecular imprinted polymer (MIP) performance. The diversity and at times inappropriateness of MIP performance indicators means that the usefulness of the literature back-catalogue, for predicting, elucidating or understanding patterns in MIP efficacy, remains largely inaccessible. We hereby put forward the case that the simple binding isotherm is the most versatile and useful method of assessing and reporting MIP function, allowing direct comparison between polymers prepared and evaluated in different studies. In this study we describe how to correctly plot and interpret a bound / free isotherm and show how such plots can be readily used to predict outcomes, retro-analyze data and optimize experimental design. We propose that by adopting the use of correctly constructed isotherms as the primary form of data representation researchers will enable inter-laboratory comparisons, promote good experimental design and encourage a greater collective understanding of molecular imprinting.


Assuntos
Impressão Molecular/normas , Polímeros/química , Polímeros/normas , Atenção , Ligantes , Modelos Teóricos , Impressão Molecular/tendências , Padrões de Referência , Projetos de Pesquisa/normas , Sensibilidade e Especificidade , Estatística como Assunto/normas
13.
J Mol Recognit ; 22(3): 223-31, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19177493

RESUMO

The aim of this work was to produce a thin, flexible and diffusion able molecularly imprinted polymeric matrix with good template accessibility. Membranes were prepared using a non-covalent molecular imprinting approach and their physical characteristics and binding capabilities investigated. Two materials were used, a poly(tri-ethyleneglycol dimethyacrylate-co-methyl methacrylate-co-methacrylic acid) copolymer containing 14% cross-linker and a monomer (g) to porogen (ml) ratio of 1:0.5 (A), and a blend of poly(TEGMA-co-MAA) and polyurethane (B). The polyurethane was added to improve membrane flexiblity and stability. The polymers were characterized using AFM, SEM and nitrogen adsorption, whilst binding was evaluated using batch-rebinding studies. For all membranes the specific surface area was low (<10 m(2)/g). MIP (A) films were shown to bind specifically at low concentrations but specific binding was masked by non-specific interactions at elevated concentrations. Selectivity studies confirmed specificity at low concentrations. K(D) approximations confirmed a difference in the population of binding sites within NIP and MIP films. The data also indicated that at low concentrations the ligand-occupied binding site population approached homogeneity. Scanning electron microscopy images of membrane (B) revealed a complex multi-layered system, however these membranes did not demonstrate specificity for the template. The results described here demonstrate how the fundamental parameters of a non-covalent molecularly imprinted system can be successfully modified in order to generate flexible and physically tolerant molecularly imprinted thin films.


Assuntos
Membranas Artificiais , Impressão Molecular/métodos , Maleabilidade , Poliuretanos/química , Teofilina/química , Adsorção , Reagentes de Ligações Cruzadas/química , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Nitrogênio/química , Temperatura
14.
Adv Drug Deliv Rev ; 57(12): 1733-41, 2005 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-16253386

RESUMO

Specific molecular recognition is a fundamental requirement of living systems on which processes as diverse as neural transmittance, respiration, immune defence, cellular differentiation and nutrition rely. It is therefore not surprising that scientists have invested huge amounts of time and effort into harnessing, and more recently mimicking, biological function. A number of synthetic approaches have been developed and one of the most promising of these is molecular imprinting. Molecular imprinted polymers have routinely been used, as robust and effective synthetic molecular receptors, in a diverse range of technologies. But it is perhaps in the area of drug delivery, in particular 'intelligent drug release' and 'magic bullet' drug targeting, that significant future opportunities lie.


Assuntos
Materiais Biomiméticos/administração & dosagem , Sistemas de Liberação de Medicamentos , Polímeros/química , Tecnologia Farmacêutica , Materiais Biomiméticos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...