Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Front Cardiovasc Med ; 10: 1095931, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910532

RESUMO

Aim: This study sought to develop and validate diagnostic models to identify individuals with atrial fibrillation (AF) using amplified sinus-p-wave analysis. Methods: A total of 1,492 patients (491 healthy controls, 499 with paroxysmal AF and 502 with persistent AF) underwent digital 12-lead-ECG recording during sinus rhythm. The patient cohort was divided into training and validation set in a 3:2 ratio. P-wave indices (PWI) including duration of standard p-wave (standard PWD; scale at 10 mm/mV, sweep speed at 25 mm/s) and amplified sinus-p-wave (APWD, scale at 60-120 mm/mV, sweep speed at 100 mm/s) and advanced inter-atrial block (aIAB) along with other clinical parameters were used to develop diagnostic models using logistic regression. Each model was developed from the training set and further tested in both training and validation sets for its diagnostic performance in identifying individuals with AF. Results: Compared to standard PWD (Reference model), which achieved an AUC of 0.637 and 0.632, for training and validation set, respectively, APWD (Basic model) importantly improved the accuracy to identify individuals with AF (AUC = 0.86 and 0.866). The PWI-based model combining APWD, aIAB and body surface area (BSA) further improved the diagnostic performance for AF (AUC = 0.892 and 0.885). The integrated model, which further combined left atrial diameter (LAD) with parameters of the PWI-based model, achieved optimal diagnostic performance (AUC = 0.916 and 0.902). Conclusion: Analysis of amplified p-wave during sinus rhythm allows identification of individuals with atrial fibrillation.

2.
Front Cardiovasc Med ; 9: 1000027, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36330001

RESUMO

Background: Low-voltage-substrate (LVS)-guided ablation for persistent atrial fibrillation (AF) has been described either in sinus rhythm (SR) or AF. Prolonged fractionated potentials (PFPs) may represent arrhythmogenic slow conduction substrate and potentially co-localize with LVS. We assess the spatial correlation of PFP identified in AF (PFP-AF) to those mapped in SR (PFP-SR). We further report the relationship between LVS and PFPs when mapped in AF or SR. Materials and methods: Thirty-eight patients with ablation naïve persistent AF underwent left atrial (LA) high-density mapping in AF and SR prior to catheter ablation. Areas presenting PFP-AF and PFP-SR were annotated during mapping on the LA geometry. Low-voltage areas (LVA) were quantified using a bipolar threshold of 0.5 mV during both AF and SR mapping. Concordance of fractionated potentials (CFP) (defined as the presence of PFPs in both rhythms within a radius of 6 mm) was quantified. Spatial distribution and correlation of PFP and CFP with LVA were assessed. The predictors for CFP were determined. Results: PFPs displayed low voltages both during AF (median 0.30 mV (Q1-Q3: 0.20-0.50 mV) and SR (median 0.35 mV (Q1-Q3: 0.20-0.56 mV). The duration of PFP-SR was measured at 61 ms (Q1-Q3: 51-76 ms). During SR, most PFP-SRs (89.4 and 97.2%) were located within LVA (<0.5 mV and <1.0 mV, respectively). Areas presenting PFP occurred more frequently in AF than in SR (median: 9.5 vs. 8.0, p = 0.005). Both PFP-AF and PFP-SR were predominantly located at anterior LA (>40%), followed by posterior LA (>20%) and septal LA (>15%). The extent of LVA < 0.5 mV was more extensive in AF (median: 25.2% of LA surface, Q1-Q3:16.6-50.5%) than in SR (median: 12.3%, Q1-Q3: 4.7-29.4%, p = 0.001). CFP in both rhythms occurred in 80% of PFP-SR and 59% of PFP-AF (p = 0.008). Notably, CFP was positively correlated to the extent of LVA in SR (p = 0.004), but not with LVA in AF (p = 0.226). Additionally, the extent of LVA < 0.5 mV in SR was the only significant predictor for CFP, with an optimal threshold of 16% predicting high (>80%) fractionation concordance in AF and SR. Conclusion: Substrate mapping in SR vs. AF reveals smaller areas of low voltage and fewer sites with PFP. PFP-SR are located within low-voltage areas in SR. There is a high degree of spatial agreement (80%) between PFP-AF and PFP-SR in patients with moderate LVA in SR (>16% of LA surface). These findings should be considered when substrate-based ablation strategies are applied in patients with the left atrial low-voltage substrate with recurrent persistent AF.

3.
Europace ; 24(7): 1102-1111, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35298612

RESUMO

AIMS: Atrial cardiomyopathy (ACM) is associated with increased arrhythmia recurrence rates after pulmonary vein isolation (PVI). We compare the most common left atrial (LA) late gadolinium enhancement magnetic resonance imaging (LGE-MRI)-methods [Utah-method and image intensity ratio (IIR)-methods] and endocardial voltage mapping for ACM-detection and outcome prediction after PVI for atrial fibrillation (AF). METHODS AND RESULTS: In this prospective observational study, 37 ablation-naive patients (66 ± 9 years, 84% male) with persistent AF underwent LA-LGE-MRI and high-definition voltage and activation mapping (2129 ± 484 sites) in sinus rhythm prior to PVI. The MRI-post-processing-analyses were performed by two independent expert laboratories. Arrhythmia recurrence was recorded within 12 months following PVI. The global ACM-extent was highly variable: median LA low-voltage substrate (LA-LVS) was 12.9% at <1.0 mV and 2.7% at <0.5 mV; median LA-LGE-extent using the Utah-method was 18.3% and 0.03-93.1% using the IIR-methods. The LA activation time was significantly correlated with LA-LVS (r = 0.76 at <0.5 mV and r = 0.82 at <1.0 mV, both P < 0.0001), but not with LA-LGE-extent. The highest regional matching between LA-LVS <0.5 mV and LA-LGE was found for the anterior wall in 57% of patients using the Utah-method and in 59% using IIR 1.20. The corresponding values for the posterior wall were 19% and 38%, respectively. Arrhythmia recurrence occurred in 15(41%) patients. Freedom from arrhythmia was significantly lower in those with LA-LVS ≥2 cm2 at 0.5 mV but not in those with LGE ≥20% (Utah-stages III and IV): 43% vs. 81%, P = 0.009 and 50% vs. 67%, P = 0.338, respectively. CONCLUSION: Comparison of the most common LA-LGE-MRI methods and endocardial voltage mapping revealed large discrepancies in global and regional ACM-extent.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Meios de Contraste , Feminino , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
4.
Front Cardiovasc Med ; 9: 1101152, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36712269

RESUMO

Background: Progressive atrial fibrotic remodeling has been reported to be associated with atrial cardiomyopathy (ACM) and the transition from paroxysmal to persistent atrial fibrillation (AF). We sought to identify the anatomical/structural and electrophysiological factors involved in atrial remodeling that promote AF persistency. Methods: Consecutive patients with paroxysmal (n = 134) or persistent (n = 136) AF who presented for their first AF ablation procedure were included. Patients underwent left atrial (LA) high-definition mapping (1,835 ± 421 sites/map) during sinus rhythm (SR) and were randomized to training and validation sets for model development and evaluation. A total of 62 parameters from both electro-anatomical mapping and non-invasive baseline data were extracted encompassing four main categories: (1) LA size, (2) extent of low-voltage-substrate (LVS), (3) LA voltages and (4) bi-atrial conduction time as identified by the duration of amplified P-wave (APWD) in a digital 12-lead-ECG. Least absolute shrinkage and selection operator (LASSO) and logistic regression were performed to identify the factors that are most relevant to AF persistency in each category alone and all categories combined. The performance of the developed models for diagnosis of AF persistency was validated regarding discrimination, calibration and clinical usefulness. In addition, HATCH score and C2HEST score were also evaluated for their performance in identification of AF persistency. Results: In training and validation sets, APWD (threshold 151 ms), LA volume (LAV, threshold 94 mL), bipolar LVS area < 1.0 mV (threshold 4.55 cm2) and LA global mean voltage (GMV, threshold 1.66 mV) were identified as best determinants for AF persistency in the respective category. Moreover, APWD (AUC 0.851 and 0.801) and LA volume (AUC 0.788 and 0.741) achieved better discrimination between AF types than LVS extent (AUC 0.783 and 0.682) and GMV (AUC 0.751 and 0.707). The integrated model (combining APWD and LAV) yielded the best discrimination performance between AF types (AUC 0.876 in training set and 0.830 in validation set). In contrast, HATCH score and C2HEST score only achieved AUC < 0.60 in identifying individuals with persistent AF in current study. Conclusion: Among 62 electro-anatomical parameters, we identified APWD, LA volume, LVS extent, and mean LA voltage as the four determinant electrophysiological and structural factors that are most relevant for AF persistency. Notably, the combination of APWD with LA volume enabled discrimination between paroxysmal and persistent AF with high accuracy, emphasizing their importance as underlying substrate of persistent AF.

5.
Front Physiol ; 12: 670527, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34421634

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia and a significant burden for healthcare systems worldwide. Presence of relevant atrial cardiomyopathy (ACM) is related to persistent AF and increased arrhythmia recurrence rates after pulmonary vein isolation (PVI). OBJECTIVE: To investigate the association of left atrial pressure (LAP), left atrial electrical [invasive atrial activation time (IAAT) and amplified p-wave duration (aPWD)] and mechanical [left atrial emptying fraction (LA-EF) and left atrial strain (LAS)] functional parameters with the extent of ACM and their impact on arrhythmia recurrence following PVI. MATERIALS AND METHODS: Fifty patients [age 67 (IQR: 61-75) years, 78% male] undergoing their first PVI for persistent AF were prospectively included. LAP (maximum amplitude of the v-wave), digital 12-lead electrocardiogram, echocardiography and high-density endocardial contact mapping were acquired in sinus rhythm prior to PVI. Arrhythmia recurrence was assessed using 72-hour Holter electrocardiogram at 6 and 12 months post PVI. RESULTS: Relevant ACM (defined as left atrial low-voltage extent ≥2 cm2 at <0.5 mV threshold) was diagnosed in 25/50 (50%) patients. Compared to patients without ACM, patients with ACM had higher LAP [17.6 (10.6-19.5) mmHg with ACM versus 11.3 (7.9-14.0) mmHg without ACM (p = 0.009)]. The corresponding values for the electrical parameters were 166 (149-181) ms versus 139 (131-143) ms for IAAT (p < 0.0001), 163 (154-176) ms versus 148 (136-152) ms for aPWD on surface-ECG (p < 0.0001) and for the mechanical parameters 27.0 (17.5-37.0) % versus 41.0 (35.0-45.0) % for LA-EF in standard 2D-echocardiography (p < 0.0001) and 15.2 (11.0-21.2) % versus 29.4 (24.9-36.6) % for LAS during reservoir phase (p < 0.0001). Furthermore, all parameters showed a linear correlation with ACM extent (p < 0.05 for all). Receiver-operator-curve-analysis demonstrated a LAP ≥12.4 mmHg [area under the curve (AUC): 0.717, sensitivity: 72%, and specificity: 60%], a prolonged IAAT ≥143 ms (AUC: 0.899, sensitivity: 84%, and specificity: 80%), a prolonged aPWD ≥153 ms (AUC: 0.860, sensitivity: 80%, and specificity: 79%), an impaired LA-EF ≤33% (AUC: 0.869, sensitivity: 84%, and specificity: 72%), and an impaired LAS during reservoir phase ≤23% (AUC: 0.884, sensitivity: 84%, and specificity: 84%) as predictors for relevant ACM. Arrhythmia recurrence within 12 months post PVI was significantly increased in patients with relevant ACM ≥2 cm2, electrical dysfunction with prolonged IAAT ≥143 ms and mechanical dysfunction with impaired LA-EF ≤33% (66 versus 20, 50 versus 23 and 55 versus 25%, all p < 0.05). CONCLUSION: Left atrial hypertension, electrical conduction slowing and mechanical dysfunction are associated with ACM. These findings improve the understanding of ACM pathophysiology and may be suitable for risk stratification for new-onset AF, arrhythmia recurrence following PVI, and development of novel therapeutic strategies to prevent AF and its associated complications.

6.
Europace ; 23(12): 2010-2019, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34463710

RESUMO

AIMS: Atrial cardiomyopathy (ACM) is associated with new-onset atrial fibrillation, arrhythmia recurrence after pulmonary vein isolation (PVI) and increased risk for stroke. At present, diagnosis of ACM is feasible by endocardial contact mapping of left atrial (LA) low-voltage substrate (LVS) or late gadolinium-enhanced magnetic resonance imaging, but their complexity limits a widespread use. The aim of this study was to assess non-invasive body surface electrocardiographic imaging (ECGI) as a novel clinical tool for diagnosis of ACM compared with endocardial mapping. METHODS AND RESULTS: Thirty-nine consecutive patients (66 ± 9 years, 85% male) presenting for their first PVI for persistent atrial fibrillation underwent ECGI in sinus rhythm using a 252-electrode-array mapping system. Subsequently, high-density LA voltage and biatrial activation maps (mean 2090 ± 488 sites) were acquired in sinus rhythm prior to PVI. Freedom from arrhythmia recurrence was assessed within 12 months follow-up. Increased duration of total atrial conduction time (TACT) in ECGI was associated with both increased atrial activation time and extent of LA-LVS in endocardial contact mapping (r = 0.77 and r = 0.66, P < 0.0001 respectively). Atrial cardiomyopathy was found in 23 (59%) patients. A TACT value of 148 ms identified ACM with 91.3% sensitivity and 93.7% specificity. Arrhythmia recurrence occurred in 15 (38%) patients during a follow-up of 389 ± 55 days. Freedom from arrhythmia was significantly higher in patients with a TACT <148 ms compared with patients with a TACT ≥148 ms (82.4% vs. 45.5%, P = 0.019). CONCLUSION: Analysis of TACT in non-invasive ECGI allows diagnosis of patients with ACM, which is associated with a significantly increased risk for arrhythmia recurrence following PVI.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
Clin Res Cardiol ; 110(11): 1770-1780, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33914144

RESUMO

BACKGROUND: Relevant atrial cardiomyopathy (ACM), defined as a left atrial (LA) low-voltage area ≥ 2 cm2 at 0.5 mV threshold on endocardial contact mapping, is associated with new-onset atrial fibrillation (AF), higher arrhythmia recurrence rates after pulmonary vein isolation (PVI), and an increased risk of stroke. The current study aimed to assess two non-invasive echocardiographic parameters, LA emptying fraction (EF) and LA longitudinal strain (LAS, during reservoir (LASr), conduit (LAScd) and contraction phase (LASct)) for the diagnosis of ACM and prediction of arrhythmia outcome after PVI. METHODS: We prospectively enrolled 60 consecutive, ablation-naive patients (age 66 ± 9 years, 80% males) with persistent AF. In 30 patients (derivation cohort), LA-EF and LAS cut-off values for the presence of relevant ACM (high-density endocardial contact mapping in sinus rhythm prior to PVI at 3000 ± 1249 sites) were established in sinus rhythm and tested in a validation cohort (n = 30). Arrhythmia recurrence within 12 months was documented using 72-h Holter electrocardiograms. RESULTS: An LA-EF of < 34% predicted ACM with an area under the curve (AUC) of 0.846 (sensitivity 69.2%, specificity 76.5%) similar to a LASr < 23.5% (AUC 0.878, sensitivity 92.3%, specificity 82.4%). In the validation cohort, these cut-offs established the correct diagnosis of ACM in 76% of patients (positive predictive values 87%/93% and negative predictive values 73%/75%, respectively). Arrhythmia recurrence in the entire cohort was significantly more frequent in patients with LA-EF < 34% and LASr < 23.5% (56% vs. 29% and 55% vs. 26%, both p < 0.05). CONCLUSION: The echocardiographic parameters LA-EF and LAS allow accurate, non-invasive diagnosis of ACM and prediction of arrhythmia recurrence after PVI.


Assuntos
Função do Átrio Esquerdo/fisiologia , Cardiomiopatias/diagnóstico , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Veias Pulmonares/cirurgia , Idoso , Mapeamento Potencial de Superfície Corporal/métodos , Cardiomiopatias/fisiopatologia , Cardiomiopatias/cirurgia , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva
8.
Europace ; 21(10): 1484-1493, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31280323

RESUMO

AIMS: Atrial fibrosis contributes to arrhythmogenesis in atrial fibrillation and can be detected by MRI or electrophysiological mapping. The current study compares the spatial correlation between delayed enhancement (DE) areas to low-voltage areas (LVAs) and to arrhythmogenic areas with spatio-temporal dispersion (ST-Disp) or continuous activity (CA) in atrial fibrillation (AF). METHODS AND RESULTS: Sixteen patients with persistent AF (nine long-standing) underwent DE-magnetic resonance imaging (1.25 mm × 1.25 mm × 2.5 mm) prior to pulmonary vein isolation. Left atrial (LA) voltage mapping was acquired in AF and the regional activation patterns of 7680 AF wavelets were analysed. Sites with ST-Disp or CA were characterized (voltage, duration) and their spatial relationship to DE areas and LVAs <0.5 mV was assessed. Delayed enhancement areas and LVAs covered 55% and 24% (P < 0.01) of total LA surface, respectively. Delayed enhancement area was present at 61% of LVAs, whereas low voltage was present at 28% of DE areas. Most DE areas (72%) overlapped with atrial high-voltage areas (>0.5 mV). Spatio-temporal dispersion and CA more frequently co-localized with LVAs than with DE areas (78% vs. 63%, P = 0.02). Regional bipolar voltage of ST-Disp vs. CA was 0.64 ± 0.47 mV vs. 0.58 ± 0.51 mV. All 28 ST-Disp and 56 CA areas contained electrograms with prolonged duration (115 ± 14 ms) displaying low voltage (0.34 ± 0.11 mV). CONCLUSION: A small portion of DE areas and LVAs harbour the arrhythmogenic areas displaying ST-Disp or CA. Most arrhythmogenic activities co-localized with LVAs, while there was less co-localization with DE areas. There is an important mismatch between DE areas and LVAs which needs to be considered when used as target for catheter ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo/fisiologia , Átrios do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Meglumina/farmacologia , Miocárdio/patologia , Compostos Organometálicos/farmacologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Meios de Contraste/farmacologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Fibrose/patologia , Gadolínio , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
10.
Artigo em Inglês | MEDLINE | ID: mdl-26966286

RESUMO

BACKGROUND: Complex-fractionated atrial electrograms and atrial fibrosis are associated with maintenance of persistent atrial fibrillation (AF). We hypothesized that pulmonary vein isolation (PVI) plus ablation of selective atrial low-voltage sites may be more successful than PVI only. METHODS AND RESULTS: A total of 85 consecutive patients with persistent AF underwent high-density atrial voltage mapping, PVI, and ablation at low-voltage areas (LVA < 0.5 mV in AF) associated with electric activity lasting > 70% of AF cycle length on a single electrode (fractionated activity) or multiple electrodes around the circumferential mapping catheter (rotational activity) or discrete rapid local activity (group I). The procedural end point was AF termination. Arrhythmia freedom was compared with a control group (66 patients) undergoing PVI only (group II). PVI alone was performed in 23 of 85 (27%) patients of group I with low amount (< 10% of left atrial surface area) of atrial low voltage. Selective atrial ablation in addition to PVI was performed in 62 patients with termination of AF in 45 (73%) after 11 ± 9 minutes radiofrequency delivery. AF-termination sites colocalized within LVA in 80% and at border zones in 20%. Single-procedural arrhythmia freedom at 13 months median follow-up was achieved in 59 of 85 (69%) patients in group I, which was significantly higher than the matched control group (31/66 [47%], P < 0.001). There was no significant difference in the success rate of patients in group I with a low amount of low voltage undergoing PVI only and patients requiring PVI+selective low-voltage ablation (P = 0.42). CONCLUSIONS: Ablation of sites with distinct activation characteristics within/at borderzones of LVA in addition to PVI is more effective than conventional PVI-only strategy for persistent AF. PVI only seems to be sufficient to treat patients with left atrial low voltage < 10%.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Intervalo Livre de Doença , Eletrodos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Indução de Remissão , Fatores de Tempo , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 25(7): 701-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24575734

RESUMO

INTRODUCTION: Pulmonary vein reconnection (PVR) is an important cause of AF recurrence after ablation. With the advent of force sensing catheters, catheter-tissue contact can be determined quantitatively. Since contact force (CF) plays a major role in determining the characteristics of RF lesion, we prospectively assessed the mechanisms of PVR with regard to catheter-contact and lesion distances in patients undergoing AF ablation. METHODS AND RESULTS: Forty symptomatic AF patients underwent wide circumferential PV isolation (PVI) with SmartTouch™ CF catheter. The exact locations of acute PVI and spontaneous or adenosine-provoked PVR were annotated on CARTO. One thousand nine hundred and twenty-six RF lesions isolated 153 PVs. PVR occurred in 35 (23%) PVs: 22 (63%) adenosine-provoked and 13 (37%) spontaneous. CF was significantly lower at PVR versus PVI sites for RF lesions within 6 mm from these sites: mean CF 5 versus 11 g (P < 0.0001) and force-time integral (FTI) 225 versus 415 gs (P < 0.0001); 86% of PVR occurred with a mean CF < 10 g (FTI < 400 gs); and the remaining 14% occurred at ablation sites with a long interlesion distance (≥5 mm) despite mean CF ≥ 10 g. Eighty percent of PVR sites were located anteriorly. There were no significant differences in regard to arrhythmia freedom between the patients without (69%) versus with PVR (67%; P = 1.0). CONCLUSIONS: Acutely durable PVI can be achieved when RF lesions are delivered with a mean CF ≥ 10 g and an interlesion distance <5 mm. The majority of PVR occur anteriorly due to inadequate CF or long interlesion distances.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Adenosina , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo , Transdutores de Pressão , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 24(12): 1328-35, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23889915

RESUMO

INTRODUCTION: Irrigated tip radiofrequency (RF) catheter ablation is the most frequently used technology for pulmonary vein isolation (PVI). The purpose of this study was to compare the efficiency and the safety of 2 different open irrigated tip RF ablation catheters. METHODS AND RESULTS: A total of 160 patients with symptomatic AF (29% persistent, 68% male, 61 ± 10 years) were randomized to circumferential PVI using 2 different irrigated tip catheters: (1) the novel Thermocool SF(®) with a porous tip (56 holes) or (2) the Thermocool(®) catheter with 6 irrigation holes at the distal tip in both power- and temperature-controlled modes. PVI procedural time and RF duration were significantly shorter with SF(®) versus Thermocool(®) catheter: 104.5 versus 114 minutes (P = 0.023) and 35.4 minutes versus 39.9 minutes (P < 0.001), respectively. Similarly, the total fluoroscopy time and dose were shorter with SF(®) versus. Thermocool(®) catheter: 21 minutes versus 24 minutes (P = 0.02) and 1014.5 µGy*m(2) versus 1377 µGy*m(2) (P < 0.0001), respectively. Irrigation volume was lower with SF(®): 600 mL versus 1100 mL, (P < 0.0001) and the rates of complications were not significantly different (0.6% vs 0.49%, P = 0.66). At 20.5 ± 7.5 months follow-up, there were no significant differences with regard to arrhythmia freedom between SF(®) (59.2%) and TC® groups (59.3%), (P = 0.61). CONCLUSIONS: Using the novel irrigated tip SF catheter, PVI is achieved within a shorter ablation and procedural durations. The underlying mechanisms and potential differences in RF lesion size remain to be elucidated.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Irrigação Terapêutica/instrumentação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Desenho de Equipamento , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Porosidade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Doses de Radiação , Radiografia Intervencionista/métodos , Fatores de Tempo , Resultado do Tratamento
13.
J Med Case Rep ; 2: 120, 2008 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-18433498

RESUMO

INTRODUCTION: The diseases responsible for sudden deaths in athletes differ considerably with regard to age. In young athletes, congenital malformations of the heart and/or vascular system cause the majority of deaths and can only be detected noninvasively by complex diagnostics. In contrast, in older athletes who die suddenly, atherosclerotic disease of the coronary arteries is mostly found. Reports of congenital coronary anomalies as a cause of sudden death in older athletes are rare. CASE PRESENTATION: A 48-year-old man who was a well-trained, long-distance runner collapsed at the finish of a half marathon because of a myocardial infarction with ventricular fibrillation. Coronary angiography showed an anomalous origin of the right coronary artery from the left sinus of Valsalva with minimal wall alterations. Multislice computed tomography of the coronary arteries confirmed these findings. Cardiomagnetic resonance imaging demonstrated a mild hypokinesia of the basal right- and left-ventricular posterior wall. An electrophysiological study showed an inducible temporary polymorphic ventricular tachycardia and an inducible ventricular fibrillation. The athlete was subsequently treated by acetylsalicylic acid 100 mg (0-1-0), bisoprolol 2.5 mg (1-0-0) and atorvastatin 10 mg (0-0-1) and was instructed to keep his training intensity under the 'individual anaerobic threshold'. Intense and long-lasting exercise under extreme environmental conditions, particularly heat, should also be avoided. CONCLUSION: This case report presents a coronary anomaly as the most likely reason for an exercise-induced myocardial infarction with ventricular fibrillation in a well-trained 48-year-old endurance athlete. Therefore, coronary anomalies have also to be considered as a possible cause of cardiac problems in older athletes.

14.
Eur Heart J ; 28(14): 1694-701, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17576661

RESUMO

AIMS: Obesity is associated with diabetes mellitus and advanced coronary artery disease (CAD). Once a non-ST-elevation acute coronary syndrome has occurred, the association between obesity and prognosis is poorly defined. This study was designed to assess the impact of obesity on outcome after unstable angina/non-ST-segment elevation myocardial infarction (UA/NSTEMI) treated with early revascularization. METHODS AND RESULTS: In a prospective cohort study in 1676 consecutive patients with UA/NSTEMI we examined the association between presence of obesity and all-cause mortality. All patients underwent coronary angiography and, if appropriate, early catheter-based revascularization. Patients were divided into four groups according to body mass index (BMI): normal, 18.5-24.9 (n = 551); overweight, 25-29.9 (n = 824); obese, 30-34.9 (n = 244); and very obese, above 35 (n = 48). Obese and very obese patients were younger and had a higher incidence of hypertension, diabetes mellitus, elevated cardiac troponin T, and C-reactive protein levels. The angiographic extent of CAD was similar among the BMI groups. Median follow-up was 17 (interquartile range 6-31) months. Cumulative 3-year mortality rates were 9.9% for normal BMI, 7.7% for overweight, 3.6% for obese, and 0 (no death) for very obese (log-rank P = 0.043). Obese and very obese patients had less than half the long-term mortality when compared with normal BMI patients [hazard ratio (HR) 0.38, 95% confidence interval (CI) 0.18-0.81, P = 0.012]. This result remained significant after adjustment for confounding prognostic factors including coronary status and left ventricular function (adjusted HR 0.27, 95% CI 0.08-0.92, P = 0.036). CONCLUSION: Obesity is associated with improved outcome after UA/NSTEMI treated with early revascularization.


Assuntos
Angina Instável/mortalidade , Infarto do Miocárdio/mortalidade , Obesidade/complicações , Idoso , Angina Instável/etiologia , Angiografia Coronária/métodos , Diabetes Mellitus/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/terapia , Revascularização Miocárdica/métodos , Estudos Prospectivos , Análise de Regressão , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...