Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hear Res ; 331: 13-26, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26471198

RESUMO

The multi-channel cochlear implant (CI) provides sound and speech perception to thousands of individuals who would otherwise be deaf. Broad activation of auditory nerve fibres when using a CI results in poor frequency discrimination. The CI also provides users with poor amplitude perception due to elicitation of a narrow dynamic range. Provision of more discrete frequency perception and a greater control over amplitude may allow users to better distinguish speech in noise and to segregate sound sources. In this research, thin-film (TF) high density micro-electrode arrays and conventional platinum ring electrode arrays were used to stimulate the cochlea of rats administered sensorineural hearing loss (SNHL) via ototoxic insult, with neural responses taken at 434 multiunit clusters in the central nucleus of the inferior colliculus (CIC). Threshold, dynamic range and broadness of response were used to compare electrode arrays. A stronger current was required to elicit CIC threshold when using the TF array compared to the platinum ring electrode array. TF stimulation also elicited a narrower dynamic range than the PR counterpart. However, monopolar stimulation using the TF array produced more localised CIC responses than other stimulation strategies. These results suggest that individuals with SNHL could benefit from micro stimulation of the cochlea using a monopolar configuration which may provide discrete frequency perception when using TF electrode arrays.


Assuntos
Aminoglicosídeos/efeitos adversos , Cóclea/fisiopatologia , Perda Auditiva/induzido quimicamente , Perda Auditiva/terapia , Animais , Limiar Auditivo , Cóclea/fisiologia , Implante Coclear , Implantes Cocleares , Nervo Coclear/fisiologia , Surdez/reabilitação , Eletrofisiologia , Perda Auditiva/cirurgia , Colículos Inferiores/efeitos dos fármacos , Masculino , Microeletrodos , Ratos , Ratos Wistar , Análise de Regressão
2.
J Neural Eng ; 10(4): 046008, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23800787

RESUMO

OBJECTIVE: Auditory midbrain implants (AMI) provide inadequate frequency discrimination for open set speech perception. AMIs that can take advantage of the tonotopic laminar of the midbrain may be able to better deliver frequency specific perception and lead to enhanced performance. Stimulation strategies that best elicit frequency specific activity need to be identified. This research examined the characteristic frequency (CF) relationship between regions of the auditory cortex (AC), in response to stimulated regions of the inferior colliculus (IC), comparing monopolar, and intralaminar bipolar electrical stimulation. APPROACH: Electrical stimulation using multi-channel micro-electrode arrays in the IC was used to elicit AC responses in anaesthetized male hooded Wistar rats. The rate of activity in AC regions with CFs within 3 kHz (CF-aligned) and unaligned CFs was used to assess the frequency specificity of responses. MAIN RESULTS: Both monopolar and bipolar IC stimulation led to CF-aligned neural activity in the AC. Altering the distance between the stimulation and reference electrodes in the IC led to changes in both threshold and dynamic range, with bipolar stimulation with 400 µm spacing evoking the lowest AC threshold and widest dynamic range. At saturation, bipolar stimulation elicited a significantly higher mean spike count in the AC at CF-aligned areas than at CF-unaligned areas when electrode spacing was 400 µm or less. Bipolar stimulation using electrode spacing of 400 µm or less also elicited a higher rate of elicited activity in the AC in both CF-aligned and CF-unaligned regions than monopolar stimulation. When electrodes were spaced 600 µm apart no benefit over monopolar stimulation was observed. Furthermore, monopolar stimulation of the external cortex of the IC resulted in more localized frequency responses than bipolar stimulation when stimulation and reference sites were 200 µm apart. SIGNIFICANCE: These findings have implications for the future development of AMI, as a bipolar stimulation strategy may improve the ability of implant users to discriminate between frequencies.


Assuntos
Vias Aferentes/fisiologia , Córtex Auditivo/fisiologia , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Eletrodos Implantados , Colículos Inferiores/fisiologia , Percepção da Altura Sonora/fisiologia , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Hear Res ; 287(1-2): 30-42, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22531007

RESUMO

A broader activation of auditory nerve fibres than normal using a cochlear implant contributes to poor frequency discrimination. As cochlear implants also deliver a restricted dynamic range, this hinders the ability to segregate sound sources. Better frequency coding and control over amplitude may be achieved by limiting current spread during electrical stimulation of the cochlea and positioning electrodes closer to the modiolus. Thin-film high density microelectrode arrays and conventional platinum ring electrode arrays were used to stimulate the cochlea of urethane-anaesthetized rats and responses compared. Neurophysiological recordings were taken at 197 multi-unit clusters in the central nucleus of the inferior colliculus (CIC), a site that receives direct monaural innervation from the cochlear nucleus. CIC responses to both the platinum ring and high density electrodes were recorded and differences in activity to changes in stimulation intensity, thresholds and frequency coding of neural activation were examined. The high density electrode array elicited less CIC activity at nonspecific frequency regions than the platinum ring electrode array. The high density electrode array produced significantly lower thresholds and larger dynamic ranges than the platinum ring electrode array when positioned close to the modiolus. These results suggest that a higher density of stimulation sites on electrodes that effectively 'aim' current, combined with placement closer to the modiolus would permit finer control over charge delivery. This may equate to improved frequency specific perception and control over amplitude when using future cochlear implant devices.


Assuntos
Cóclea/inervação , Implantes Cocleares , Nervo Coclear/fisiologia , Mesencéfalo/fisiologia , Microeletrodos , Animais , Vias Auditivas/fisiologia , Limiar Auditivo , Cóclea/diagnóstico por imagem , Estimulação Elétrica , Potenciais Evocados Auditivos do Tronco Encefálico , Masculino , Platina , Desenho de Prótese , Ratos , Ratos Wistar , Fatores de Tempo , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...