Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Am Assoc Nurse Pract ; 34(10): 1139-1148, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36191325

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common cardiac arrhythmia and is emerging in prevalence with an increasingly aging population. The complex nature of the disease and its association with significant morbidity and mortality has resulted in a call for a new integrative, multidisciplinary approach to AF management. PURPOSE: Determine if the use of a nurse practitioner (NP)-led AF clinic (NPAFC) can improve care for patients. METHODOLOGY: An NPAFC was designed to serve as an independent clinic for standardizing patient care and improving access to care. Baseline patient demographics, care pathway, and interventions were characterized in clinic. Primary outcomes were hospitalizations and emergency department (ER) visits, before and after clinic implementation. RESULTS: Overall, 1,442 patients were enrolled in the AF clinic between January 2016 and June 2018. The mean age at the first AF clinic visit was 68.7 ± 12.6 years, 54% were male, and the mean body mass index was 31 ± 7 kg/m2. Among the patients, 45.2% had paroxysmal AF, 43.6% persistent AF, and 5.5% permanent AF. With an average of 3 ± 3 clinic visits per patient, the number of patients with ≥1 hospitalization decreased by 78% after clinic implementation. Similarly, the number of patients with ≥1 ER visit decreased by 79%, and 22.7% of patients avoided at least one ER visit. CONCLUSIONS: The number of patients with ≥1 hospitalization or ≥1ER visit decreased within two years after the implementation of an NPAFC. IMPLICATIONS: Implementation of an NP-led AF clinic in the United States may reduce hospitalizations and ER visits if implemented in an integrative model.


Assuntos
Fibrilação Atrial , Profissionais de Enfermagem , Idoso , Fibrilação Atrial/terapia , Serviço Hospitalar de Emergência , Feminino , Hospitalização , Humanos , Masculino , Aceitação pelo Paciente de Cuidados de Saúde , Estados Unidos
2.
Heart Rhythm O2 ; 2(5): 463-471, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34667961

RESUMO

BACKGROUND: High adherence to remote monitoring (RM) in pacemaker (PM) patients improves outcomes; however, adherence remains suboptimal. Bluetooth low-energy (BLE) technology in newer-generation PMs enables communication directly with patient-owned smart devices using an app without a bedside console. OBJECTIVE: To evaluate the success rate of scheduled RM transmissions using the app compared to other RM methods. METHODS: The BlueSync Field Evaluation was a prospective, international cohort evaluation, measuring the success rate of scheduled RM transmissions using a BLE PM or cardiac resynchronization therapy PM coupled with the MyCareLink Heart app. App transmission success was compared to 3 historical "control" groups from the Medtronic de-identified CareLink database: (1) PM patients with manual communication using a wand with a bedside console (PM manual transmission), (2) PM patients with wireless automatic communication with the bedside console (PM wireless); (3) defibrillator patients with similar automatic communication (defibrillator wireless). RESULTS: Among 245 patients enrolled (age 64.8±15.6 years, 58.4% men), 953 transmissions were scheduled through 12 months, of which 902 (94.6%) were successfully completed. In comparison, transmission success rates were 56.3% for PM manual transmission patients, 77.0% for PM wireless patients, and 87.1% for defibrillator wireless patients. Transmission success with the app was superior across matched cohorts based on age, sex, and device type (single vs dual vs triple chamber). CONCLUSION: The success rate of scheduled RM transmissions was higher among patients using the smart device app compared to patients using traditional RM using bedside consoles. This novel technology may improve patient engagement and adherence to RM.

3.
J Stroke Cerebrovasc Dis ; 29(9): 104934, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32807411

RESUMO

BACKGROUND AND PURPOSE: Use of implantable cardiac monitors (ICMs) has increased diagnosis of atrial fibrillation (AF) in cryptogenic stroke (CS) patients. Identifying AF predictors may enhance the yield of AF detection. Recurrent strokes after CS are not well described. We aimed to assess the predictors for AF detection and the characteristics of recurrent strokes in patients after CS. METHODS: We reviewed electronic medical records of CS patients who were admitted between February 2014 and September 2017 and underwent ICM placement with minimum one-year follow-up. Patient demographics, stroke characteristics, pre-defined risk factors as well as recurrent strokes were compared between patients with and without AF detection. RESULTS: 389 patients with median follow-up of 548 days were studied. AF was detected in 102 patients (26.2%). Age (per decade increase, OR 2.10, CI 1.64-2.68, with vs. without AF) and left atrium diameter (per 5 mm increase, OR 1.91, CI 1.33-2.74) were identified as AF predictors. Intracranial large vessel stenosis >50% irrelevant to the index strokes was associated with AF detection within 30 days (OR 0.24, CI 0.09-0.69, >30 vs. <30 days). Recurrent strokes occurred in 14% patients with median follow-up about 2.5 years. Topography of these strokes resembled embolic pattern and was comparable between patients with and without AF. Among recurrent strokes in patients with AF, the median time to AF detection was much shorter (90 vs. 251 days), and the median time to first stroke recurrence was much longer (422 vs. 76 days) in patients whose strokes recurred after AF detection than those before AF detection. CONCLUSIONS: Older age and enlarged left atrium are predictors for AF detection in CS patients. Intracranial atherosclerosis is more prevalent in patients with early AF detection within 30 days. Recurrent strokes follow the embolic pattern, and early AF detection could delay the stroke recurrence.


Assuntos
Fibrilação Atrial/diagnóstico , Embolia/diagnóstico , Tecnologia de Sensoriamento Remoto/instrumentação , Acidente Vascular Cerebral/diagnóstico , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Diagnóstico Tardio , Registros Eletrônicos de Saúde , Embolia/epidemiologia , Embolia/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina/epidemiologia , Valor Preditivo dos Testes , Prevalência , Prognóstico , Recidiva , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo
5.
J Interv Card Electrophysiol ; 57(1): 141-147, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31612300

RESUMO

PURPOSE: Approximately 10-40% of strokes are cryptogenic (CS). Long-term electrocardiographic (ECG) monitoring has been recommended in these patients to search for atrial fibrillation (AF). An unresolved issue is whether ambulatory ECG (AECG) monitoring should be performed first, followed by an implantable loop recorder (ILR) if AECG monitoring is non-diagnostic, or whether long-term ECG monitoring should be initiated using ILRs from the onset. The purpose of this study was to assess, using an ILR, AF incidence in the first month after CS. METHODS: We enrolled consecutive CS patients referred for an ILR. All patients were monitored via in-hospital continuous telemetry from admission until the ILR (Medtronic [Minneapolis, MN] LINQ™) was implanted. The duration and overall burden of all AF episodes ≥ 2 min was determined. RESULTS: The cohort included 343 patients (68 ± 11 years, CHA2DS2-VASc 3.5 ± 1.7). The time between stroke and ILR was 3.7 ± 1.5 days. During the first 30 days, only 18 (5%) patients had AF. All episodes were paroxysmal, lasting from 2 min to 67 h and 24 min. The median AF burden was 0.85% (IQR 0.52, 10.75). During 1 year of follow-up, 67 (21%) patients had AF. CONCLUSION: The likelihood of AF detection by an ILR in the first month post-CS is low. Thus, the diagnostic yield of 30 days of AECG monitoring is likely to be limited. These data suggest a rationale for proceeding directly to ILR implantation prior to hospital discharge in CS patients, as many have AF detected during longer follow-up.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial , Acidente Vascular Cerebral/etiologia , Idoso , Feminino , Humanos , Masculino , Fatores de Risco , Telemetria
6.
J Microbiol Methods ; 166: 105739, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31626891

RESUMO

Gut metagenome profiling using the Oxford Nanopore Technologies (ONT) sequencer was assessed in a pilot-sized study of 10 subjects. The taxonomic abundance of gut microbiota derived from ONT was comparable with Illumina Technology (IT) for the high-abundance species. IT better detected low-abundance species through amplification, when material was limited.


Assuntos
Bactérias/classificação , Microbioma Gastrointestinal/genética , Neoplasias de Cabeça e Pescoço/epidemiologia , Metagenoma/genética , Sequenciamento por Nanoporos/métodos , Idoso , Feminino , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Análise de Sequência de DNA/métodos
9.
Opt Express ; 24(26): 30328-30337, 2016 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-28059309

RESUMO

We have developed a single-shot terahertz time-domain spectrometer to perform optical-pump/terahertz-probe experiments in pulsed, high magnetic fields up to 30 T. The single-shot detection scheme for measuring a terahertz waveform incorporates a reflective echelon to create time-delayed beamlets across the intensity profile of the optical gate beam before it spatially and temporally overlaps with the terahertz radiation in a ZnTe detection crystal. After imaging the gate beam onto a camera, we can retrieve the terahertz time-domain waveform by analyzing the resulting image. To demonstrate the utility of our technique, we measured cyclotron resonance absorption of optically excited carriers in the terahertz frequency range in intrinsic silicon at high magnetic fields, with results that agree well with published values.

12.
Artigo em Inglês | MEDLINE | ID: mdl-25570704

RESUMO

Traditional metrics for evaluating the severity of psoriasis are highly subjective, which complicates efforts to identify effective treatments in clinical trials. We propose a method for the objective measurement of the psoriasis severity parameter of erythema (redness). This procedure is standardized for different camera systems and lighting environments through the usage of a color card with predetermined color values in order to calibrate the images. Quantitative measures based on the digital color images are shown to correlate well with subjective assessment of psoriasis severity collected using a standard numerical scale by a panel of dermatologists. Additionally, the color calibration process is shown to improve results.


Assuntos
Eritema/patologia , Processamento de Imagem Assistida por Computador/métodos , Fotografação/métodos , Psoríase/patologia , Algoritmos , Calibragem , Cor , Prova Pericial , Humanos , Iluminação
13.
Indian Pacing Electrophysiol J ; 10(3): 152-5, 2010 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-20234813

RESUMO

An 83-year-old man underwent electrophysiological testing for focal atrial tachycardia (AT) exhibiting narrow P waves with negative deflections in the inferior leads. Catheter ablation at the cavo-tricuspid isthmus (CTI) successfully eliminated the AT. The propagation map during AT and pacing study from the successful ablation site demonstrated that the atrial activation throughout the CTI did not produce significant P wave deflections. Consequently, during AT, the left atrial activation time determined the P wave duration. This case demonstrates that AT originating from the CTI may exhibit narrow P waves which can be misinterpreted as AT originating from the inter-atrial septum.

14.
Pacing Clin Electrophysiol ; 33(12): e114-8, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20345625

RESUMO

A 62-year-old man with idiopathic ventricular tachycardia (VT) exhibiting left bundle branch block and left inferior axis QRS morphology with a Qr in lead III underwent electrophysiological testing. Successful ablation was achieved in the left ventricle (LV) at a site with an excellent pace map, adjacent to the His bundle electrogram recording site. At that site, the sequence of the ventricular electrogram and late potential recorded during sinus rhythm reversed during spontaneous premature ventricular contractions with the same QRS morphology as the VT. This case shows that VT can arise from the LV ostium adjacent to the membranous septum.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Ablação por Cateter , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Antiasmáticos/uso terapêutico , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/cirurgia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
15.
Europace ; 11(8): 1115-7, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19395416

RESUMO

A 73-year-old man with idiopathic premature ventricular contractions (PVCs) underwent electrophysiological testing. Left ventricular activation mapping revealed a focal mechanism of the PVCs with the earliest activation on the anterior papillary muscle (APM). Irrigated radiofrequency (RF) current delivered at that site induced a cluster of non-sustained ventricular tachycardia episodes with the same QRS morphology as the PVCs, followed by ventricular fibrillation (VF). The APM might have served as an abnormal automatic trigger and driver for the VF occurrence. Ventricular fibrillation may occur as a complication during RF catheter ablation of papillary muscle ventricular arrhythmias even if the clinical arrhythmia is limited to PVCs.


Assuntos
Ablação por Cateter/efeitos adversos , Sistema de Condução Cardíaco/anormalidades , Sistema de Condução Cardíaco/cirurgia , Músculos Papilares/anormalidades , Músculos Papilares/cirurgia , Fibrilação Ventricular/etiologia , Complexos Ventriculares Prematuros/cirurgia , Idoso , Ventrículos do Coração/anormalidades , Ventrículos do Coração/cirurgia , Humanos , Masculino , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle
16.
J Cardiovasc Electrophysiol ; 20(8): 866-72, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19298560

RESUMO

INTRODUCTION: Focal ventricular arrhythmias (VAs) have been reported to arise from the posterior papillary muscle in the left ventricle (LV). We report a distinct subgroup of idiopathic VAs arising from the anterior papillary muscle (APM) in the LV. METHODS AND RESULTS: We studied 432 consecutive patients undergoing catheter ablation for VAs based on a focal mechanism. Six patients were identified with ventricular tachycardia (VT, n = 1) or premature ventricular contractions (PVCs, n = 5) with the earliest site of ventricular activation localized to the base (n = 3) or middle portion (n = 3) of the LV APM. No Purkinje potentials were recorded at the ablation site during sinus rhythm or the VAs. All patients had a normal baseline electrocardiogram and normal LV systolic function. The VAs exhibited a right bundle branch block (RBBB) and right inferior axis (RIA) QRS morphology in all patients. Oral verapamil and/or Na(+) channel blockers failed to control the VAs in 4 patients. VT was not inducible by programmed electrical stimulation in any of the patients. In 4 patients, radiofrequency current with an irrigated or conventional 8-mm-tip ablation catheter was required to achieve a lasting success. Two patients had recurrent PVCs after a conventional radiofrequency ablation with a 4-mm-tip ablation catheter had initially suppressed the arrhythmia. CONCLUSIONS: VAs may arise from the base or middle portion of the APM and are characterized by an RBBB and RIA QRS morphology and focal mechanism. Catheter ablation of APM VAs is typically challenging, and creation of a deep radiofrequency lesion may be necessary for long-term success.


Assuntos
Músculos Papilares/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Adulto , Idoso , Ablação por Cateter/métodos , Feminino , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Papilares/cirurgia , Taquicardia Ventricular/cirurgia
18.
Heart Rhythm ; 5(11): 1599-606, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18984539

RESUMO

BACKGROUND: Knowledge of the shock potential gradient (nablaV) and postshock activation is limited to internal defibrillation of short-duration ventricular fibrillation (SDVF). OBJECTIVE: The purpose of this study was to determine these variables after external defibrillation of long-duration VF (LDVF). METHODS: In six pigs, 115-20 plunge needles with three to six electrodes each were inserted to record throughout both ventricles. After the chest was closed, the biphasic defibrillation threshold (DFT) was determined after 20 seconds of SDVF with external defibrillation pads. After 7 minutes of LDVF, defibrillation shocks that were less than or equal to the SDVF DFT strength were given. RESULTS: For DFT shocks (1632 +/- 429 V), the maximum minus minimum ventricular voltage (160 +/- 100 V) was 9.8% of the shock voltage. Maximum cardiac nablaV (28.7 +/- 17 V/cm) was 4.7 +/- 2.0 times the minimum nablaV (6.2 +/- 3.5 V/cm). Although LDVF did not increase the DFT in five of the six pigs, it significantly lengthened the time to earliest postshock activation following defibrillation (1.6 +/- 2.2 seconds for SDVF and 4.9 +/- 4.3 seconds for LDVF). After LDVF, 1.3 +/- 0.8 episodes of spontaneous refibrillation occurred per animal, but there was no refibrillation after SDVF. CONCLUSION: Compared with previous studies of internal defibrillation, during external defibrillation much less of the shock voltage appears across the heart and the shock field is much more even; however, the minimum nablaV is similar. Compared with external defibrillation of SDVF, the biphasic external DFT for LDVF is not increased; however, time to earliest postshock activation triples. Refibrillation is common after LDVF but not after SDVF in these normal hearts, indicating that LDVF by itself can cause refibrillation without requiring preexisting heart disease.


Assuntos
Cardioversão Elétrica , Potenciais da Membrana/fisiologia , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia , Animais , Mapeamento Potencial de Superfície Corporal , Suínos , Fatores de Tempo
19.
Pacing Clin Electrophysiol ; 31(10): 1351-4, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18811820

RESUMO

A 32-year-old woman with a history of nonischemic dilated cardiomyopathy, left bundle branch block, left ventricular ejection fraction of 0.15, and New York Heart Association Class III congestive heart failure, despite optimal medical treatment, was referred for cardiac resynchronization therapy with implantation of an implantable cardioverter defibrillator. The patient had prior chemotherapy for non-Hodgkin's lymphoma and was shown to have chronic total occlusion of the superior vena cava (SVC) by magnetic resonance imaging. Cardiac resynchronization was accomplished with an iliofemoral approach without complications resulting in marked clinical improvement. We conclude that the iliofemoral approach allows transvenous implantation of cardiac resynchronization therapy in patients with superior vena cava occlusion.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/prevenção & controle , Marca-Passo Artificial , Implantação de Prótese/métodos , Síndrome da Veia Cava Superior/complicações , Síndrome da Veia Cava Superior/diagnóstico , Adulto , Feminino , Humanos , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 18(12): 1306-12, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17916154

RESUMO

BACKGROUND: Humans are more similar in transmural Purkinje and cardiac ion channel distributions to dogs than pigs. The Purkinje network in pigs is transmural but confined to the endocardium in dogs. Little is known about intramural activation during long-duration ventricular fibrillation (LDVF) given these differences. We tested the hypothesis that the transmural activation sequence is similar in sinus rhythm (SR) and LDVF in dogs as well as pigs, but different between species. METHODS AND RESULTS: In six pigs and seven dogs, 50-60 plunge needles (six electrodes, 2-mm spacing) were placed throughout the left ventricle. Unipolar recordings were made for >10 minutes of LDVF. SR and LDVF activation times were grouped into waves by linking activations along each needle. Origin (earliest activation) and propagation direction were determined for each wave. The mean wave origin was significantly more endocardial in dogs than pigs for SR and 1 through 10 minutes of LDVF. Predominant propagation direction in LDVF and SR was endocardial to epicardial in dogs, but the opposite or equal in both directions in pigs. Fastest activation rate was epicardial in pigs, but endocardial in dogs with an increasing endocardial-to-epicardial activation rate gradient as LDVF progressed in dogs but not pigs. CONCLUSIONS: The transmural activation sequence in SR and LDVF is markedly different between pigs and dogs. These differences may be related to differences in Purkinje fiber and ion channel distributions and suggest that dogs are a better model for investigating activation sequences during LDVF, given the similarities with humans.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Fibrilação Ventricular/fisiopatologia , Animais , Cães , Especificidade da Espécie , Suínos , Disfunção Ventricular Esquerda/etiologia , Fibrilação Ventricular/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...