Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JMIR Hum Factors ; 10: e46120, 2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37682590

RESUMO

BACKGROUND: Understanding the communication between physicians and patients can identify areas where they can improve and build stronger relationships. This led to better patient outcomes including increased engagement, enhanced adherence to treatment plan, and a boost in trust. OBJECTIVE: This study investigates eye gaze directions of physicians, patients, and computers in naturalistic medical encounters at Federally Qualified Health Centers to understand communication patterns given different patients' diverse backgrounds. The aim is to support the building and designing of health information technologies, which will facilitate the improvement of patient outcomes. METHODS: Data were obtained from 77 videotaped medical encounters in 2014 from 3 Federally Qualified Health Centers in Chicago, Illinois, that included 11 physicians and 77 patients. Self-reported surveys were collected from physicians and patients. A systematic analysis approach was used to thoroughly examine and analyze the data. The dynamics of eye gazes during interactions between physicians, patients, and computers were evaluated using the lag sequential analysis method. The objective of the study was to identify significant behavior patterns from the 6 predefined patterns initiated by both physicians and patients. The association between eye gaze patterns was examined using the Pearson chi-square test and the Yule Q test. RESULTS: The results of the lag sequential method showed that 3 out of 6 doctor-initiated gaze patterns were followed by patient-response gaze patterns. Moreover, 4 out of 6 patient-initiated patterns were significantly followed by doctor-response gaze patterns. Unlike the findings in previous studies, doctor-initiated eye gaze behavior patterns were not leading patients' eye gaze. Moreover, patient-initiated eye gaze behavior patterns were significant in certain circumstances, particularly when interacting with physicians. CONCLUSIONS: This study examined several physician-patient-computer interaction patterns in naturalistic settings using lag sequential analysis. The data indicated a significant influence of the patients' gazes on physicians. The findings revealed that physicians demonstrated a higher tendency to engage with patients by reciprocating the patient's eye gaze when the patient looked at them. However, the reverse pattern was not observed, suggesting a lack of reciprocal gaze from patients toward physicians and a tendency to not direct their gaze toward a specific object. Furthermore, patients exhibited a preference for the computer when physicians directed their eye gaze toward it.


Assuntos
Fixação Ocular , Médicos , Humanos , Chicago , Comunicação , Computadores
2.
Sensors (Basel) ; 23(16)2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37631800

RESUMO

Landmine contamination is a significant problem that has devastating consequences worldwide. Unmanned aerial vehicles (UAVs) can play an important role in solving this problem. The technology has the potential to expedite, simplify, and improve the safety and efficacy of the landmine detection process prior to physical intervention. Although the process of detecting landmines in contaminated environments is systematic, it is proven to be rather costly and overwhelming, especially if prior information about the location of the lethal objects is unknown. Therefore, automation of the process to orchestrate the search for landmines has become necessary to utilize the full potential of system components, particularly the UAV, which is the enabling technology used to airborne the sensors required in the discovery stage. UAVs have a limited amount of power at their disposal. Due to the complexity of target locations, the coverage route for UAV-based surveys must be meticulously designed to optimize resource usage and accomplish complete coverage. This study presents a framework for autonomous UAV-based landmine detection to determine the coverage route for scanning the target area. It is performed by extracting the area of interest using segmentation based on deep learning and then constructing the coverage route plan for the aerial survey. Multiple coverage path patterns are used to identify the ideal UAV route. The effectiveness of the suggested framework is evaluated using several target areas of differing sizes and complexities.

3.
Artigo em Inglês | MEDLINE | ID: mdl-34682696

RESUMO

Assessment of heart sounds which are generated by the beating heart and the resultant blood flow through it provides a valuable tool for cardiovascular disease (CVD) diagnostics. The cardiac auscultation using the classical stethoscope phonological cardiogram is known as the most famous exam method to detect heart anomalies. This exam requires a qualified cardiologist, who relies on the cardiac cycle vibration sound (heart muscle contractions and valves closure) to detect abnormalities in the heart during the pumping action. Phonocardiogram (PCG) signal represents the recording of sounds and murmurs resulting from the heart auscultation, typically with a stethoscope, as a part of medical diagnosis. For the sake of helping physicians in a clinical environment, a range of artificial intelligence methods was proposed to automatically analyze PCG signal to help in the preliminary diagnosis of different heart diseases. The aim of this research paper is providing an accurate CVD recognition model based on unsupervised and supervised machine learning methods relayed on convolutional neural network (CNN). The proposed approach is evaluated on heart sound signals from the well-known, publicly available PASCAL and PhysioNet datasets. Experimental results show that the heart cycle segmentation and segment selection processes have a direct impact on the validation accuracy, sensitivity (TPR), precision (PPV), and specificity (TNR). Based on PASCAL dataset, we obtained encouraging classification results with overall accuracy 0.87, overall precision 0.81, and overall sensitivity 0.83. Concerning Micro classification results, we obtained Micro accuracy 0.91, Micro sensitivity 0.83, Micro precision 0.84, and Micro specificity 0.92. Using PhysioNet dataset, we achieved very good results: 0.97 accuracy, 0.946 sensitivity, 0.944 precision, and 0.946 specificity.


Assuntos
Doenças Cardiovasculares , Ruídos Cardíacos , Algoritmos , Inteligência Artificial , Doenças Cardiovasculares/diagnóstico , Frequência Cardíaca , Humanos , Redes Neurais de Computação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...