Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Optom Vis Sci ; 94(8): 830-837, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28737606

RESUMO

PURPOSE: The purpose of this study was to investigate the development of visual acuity (VA) and contrast sensitivity in children as measured with objective (sweep visually evoked potential) and subjective, psychophysical techniques, including signal detection theory (SDT), which attempts to control for differences in criterion or behavior between adults and children. Furthermore, this study examines the possibility of applying SDT methods with children. METHODS: Visual acuity and contrast thresholds were measured in 12 children 6 to 7 years old, 10 children 8 to 9 years old, 10 children 10 to 12 years old, and 16 adults. For sweep visually evoked potential measurements, spatial frequency was swept from 1 to 40 cpd to measure VA, and contrast of sine-wave gratings (1 or 8 cpd) was swept from 0.33 to 30% to measure contrast thresholds. For psychophysical measurements, VA and contrast thresholds (1 or 8 cpd) were measured using a temporal two-alternative forced-choice staircase procedure and also with a yes-no SDT procedure. Optotype (logMAR [log of the minimum angle of resolution]) VA was also measured. RESULTS: The results of the various procedures were in agreement showing that there are age-related changes in threshold values and logMAR VA after the age of 6 years and that these visual functions do not become adult-like until the age of 8 to 9 years at the earliest. It was also found that children can participate in SDT procedures and do show differences in criterion compared with adults in psychophysical testing. CONCLUSIONS: These findings confirm a slightly later development of VA and contrast sensitivity (8 years or older) and indicate the importance of using SDT or forced-choice procedures in any developmental study to attempt to overcome the effect of criterion in children.


Assuntos
Comportamento de Escolha/fisiologia , Sensibilidades de Contraste , Potenciais Evocados Visuais/fisiologia , Psicofísica/métodos , Acuidade Visual , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Adulto Jovem
2.
Graefes Arch Clin Exp Ophthalmol ; 249(4): 613-23, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20694474

RESUMO

BACKGROUND: There are many parameters that may impact the thresholds obtained with sweep visually evoked potentials (sVEP), yet a number of these parameters have not been systematically studied, and there is no recognised standard for sVEP recording. In this study, the effects of electrode placement, temporal frequency, sweep direction, presence of a fixation target, stimulus area, and sweep duration on visual acuity (VA) and contrast thresholds of the sVEP were investigated. Additionally, the effect of these parameters on the number of viable threshold readings obtained from five active electrodes was investigated. METHODS: Participants were six children (aged 6-8 years) and six adults (aged 17-30 years) with normal vision. Binocular sVEP VA and contrast thresholds were measured for two electrode placements (ISCEV and PowerDiva) of five active electrodes, three temporal frequencies (6, 7.5, and 10 Hz), two sweep directions (low to high and high to low), presence or absence of a fixation target, three stimulus areas, and three sweep durations. RESULTS: There were differences between adults and children with respect to visual acuity, the adults having better VA than the children (p = 0.033 in experiment 2). Overall, there were more viable readings at 7.5 Hz than at either 10 or 6 Hz (p = 0.0014 for VA and 0.001 for contrast thresholds). The adults performed better (in terms of viable readings) with the fixation target than without it (p = 0.04). The smallest stimulus size used gave rise to fewer viable readings in both adults and children (p = 0.022 for VA and 0.0001 for contrast thresholds). The other parameters (electrode placement, sweep direction and sweep duration) did not give rise to significant differences. CONCLUSIONS: A temporal frequency of 7.5 Hz, a stimulus area of 4° or larger for VA and 10° or larger for contrast thresholds, and the use of a fixation target gave more viable readings, and may be indicated for future application. Consideration of the number of viable readings showed more differences between parameters than the actual thresholds, and it is suggested that more readings presumably would yield more reliable threshold measurements.


Assuntos
Sensibilidades de Contraste/fisiologia , Potenciais Evocados Visuais/fisiologia , Acuidade Visual/fisiologia , Adulto , Criança , Humanos , Limiar Sensorial/fisiologia , Visão Binocular/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...