Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Alzheimers Dement (Amst) ; 16(2): e12601, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38912306

RESUMO

INTRODUCTION: Recent work suggests that amyloid beta (Aß) positron emission tomography (PET) tracer uptake shortly after injection ("early phase") reflects brain metabolism and perfusion. We assessed this modality in a predominantly amyloid-negative neurodegenerative condition, Parkinson's disease (PD), and hypothesized that early-phase 18F-florbetaben (eFBB) uptake would reproduce characteristic hypometabolism and hypoperfusion patterns associated with cognitive decline in PD. METHODS: One hundred fifteen PD patients across the spectrum of cognitive impairment underwent dual-phase Aß PET, structural and arterial spin labeling (ASL) magnetic resonance imaging (MRI), and neuropsychological assessments. Multiple linear regression models compared eFBB uptake to cognitive performance and ASL MRI perfusion. RESULTS: Reduced eFBB uptake was associated with cognitive performance in brain regions previously linked to hypometabolism-associated cognitive decline in PD, independent of amyloid status. Furthermore, eFBB uptake correlated with cerebral perfusion across widespread regions. DISCUSSION: EFBB uptake is a potential surrogate measure for cerebral perfusion/metabolism. A dual-phase PET imaging approach may serve as a clinical tool for assessing cognitive impairment. Highlights: Images taken at amyloid beta (Aß) positron emission tomography tracer injection may reflect brain perfusion and metabolism.Parkinson's disease (PD) is a predominantly amyloid-negative condition.Early-phase florbetaben (eFBB) in PD was associated with cognitive performance.eFBB uptake reflects hypometabolism-related cognitive decline in PD.eFBB correlated with arterial spin labeling magnetic resonance imaging measured cerebral perfusion.eFBB distinguished dementia from normal cognition and mild cognitive impairment.Findings were independent of late-phase Aß burden.Thus, eFBB may serve as a surrogate measure for brain metabolism/perfusion.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38837669

RESUMO

In this study, we compared the fat-saturated (FS) and non-FS turbo spin echo (TSE) magnetic resonance imaging knee sequences reconstructed conventionally (conventional-TSE) against a deep learning-based reconstruction of accelerated TSE (DL-TSE) scans. A total of 232 conventional-TSE and DL-TSE image pairs were acquired for comparison. For each consenting patient, one of the clinically acquired conventional-TSE proton density-weighted sequences in the sagittal or coronal planes (FS and non-FS), or in the axial plane (non-FS), was repeated using a research DL-TSE sequence. The DL-TSE reconstruction resulted in an image resolution that increased by at least 45% and scan times that were up to 52% faster compared to the conventional TSE. All images were acquired on a MAGNETOM Vida 3T scanner (Siemens Healthineers AG, Erlangen, Germany). The reporting radiologists, blinded to the acquisition time, were requested to qualitatively compare the DL-TSE against the conventional-TSE reconstructions. Despite having a faster acquisition time, the DL-TSE was rated to depict smaller structures better for 139/232 (60%) cases, equivalent for 72/232 (31%) cases and worse for 21/232 (9%) cases compared to the conventional-TSE. Overall, the radiologists preferred the DL-TSE reconstruction in 124/232 (53%) cases and stated no preference, implying equivalence, for 65/232 (28%) cases. DL-TSE reconstructions enabled faster acquisition times while enhancing spatial resolution and preserving the image contrast. From these results, the DL-TSE provided added or comparable clinical value and utility in less time. DL-TSE offers the opportunity to further reduce the overall examination time and improve patient comfort with no loss in diagnostic accuracy.

3.
Brain Commun ; 5(1): fcac339, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36632184

RESUMO

Neuronal ceroid lipofuscinoses (Batten disease) are a group of inherited lysosomal storage disorders characterized by progressive neurodegeneration leading to motor and cognitive dysfunction, seizure activity and blindness. The disease can be caused by mutations in 1 of 13 ceroid lipofuscinosis neuronal (CLN) genes. Naturally occurring sheep models of the CLN5 and CLN6 neuronal ceroid lipofuscinoses recapitulate the clinical disease progression and post-mortem pathology of the human disease. We used longitudinal MRI to assess global and regional brain volume changes in CLN5 and CLN6 affected sheep compared to age-matched controls over 18 months. In both models, grey matter volume progressively decreased over time, while cerebrospinal fluid volume increased in affected sheep compared with controls. Total grey matter volume showed a strong positive correlation with clinical scores, while cerebrospinal fluid volume was negatively correlated with clinical scores. Cortical regions in affected animals showed significant atrophy at baseline (5 months of age) and progressively declined over the disease course. Subcortical regions were relatively spared with the exception of the caudate nucleus in CLN5 affected animals that degenerated rapidly at end-stage disease. Our results, which indicate selective vulnerability and provide a timeline of degeneration of specific brain regions in two sheep models of neuronal ceroid lipofuscinoses, will provide a clinically relevant benchmark for assessing therapeutic efficacy in subsequent trials of gene therapy for CLN5 and CLN6 disease.

4.
J Med Imaging Radiat Sci ; 54(1): 9-15, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36646549

RESUMO

INTRODUCTION: Patients with breast implants need to undergo regular screening MRI procedures. One of the key requirements of this screening scan is the ability to suppress one or more tissues (water, fat, or silicone) simultaneously. However, the presence of "foreign" implants within the breast biological space affects the MRI scanner's normal operating mode. Often, this requires operator's supervision to make sure the correct image contrast is achieved. METHODS: We built a phantom that represents the commonly encountered tissues (water, fat, and silicone) in breast implant imaging. The phantom was used to optimise imaging parameters and highlight common challenges encountered while imaging breast implants. We scanned the phantom on seven different MRI scanners (including 1.5T and 3T) and produced vendor-specific cheat-sheets on how to image breast implants. Ethical approval was not required for this article type. CONCLUSION: Performing a breast MRI procedure with implants in-situ can be challenging. Employing a purpose-built phantom, we provide easy-to-use cheat sheets, with examples, outlining steps that can be taken to ensure appropriate tissue suppression and image contrast in breast implant MRI. We hope these cheat-sheets will help MRI practitioners to confidently and efficiently achieve accurate image contrasts across a number of implant scenarios which will aid in improving diagnostic accuracy, treatment plans, and thus prognosis for the patient.


Assuntos
Implantes de Mama , Humanos , Imageamento por Ressonância Magnética/métodos , Mama , Silicones , Água
5.
Neuroimage ; 211: 116608, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32032737

RESUMO

OBJECTIVE: Many factors can contribute to the reliability and robustness of MRI-derived metrics. In this study, we assessed the reliability and reproducibility of three MRI modalities after an MRI scanner was relocated to a new hospital facility. METHODS: Twenty healthy volunteers (12 females, mean age (standard deviation) â€‹= â€‹41 (11) years, age range [25-66]) completed three MRI sessions. The first session (S1) was one week prior to the 3T GE HDxt scanner relocation. The second (S2) occurred nine weeks after S1 and at the new location; a third session (S3) was acquired 4 weeks after S2. At each session, we acquired structural T1-weighted, pseudo-continuous arterial spin labelled, and diffusion tensor imaging sequences. We used longitudinal processing streams to create 12 summary MRI metrics, including total gray matter (GM), cortical GM, subcortical GM, white matter (WM), and lateral ventricle volume; mean cortical thickness; total surface area; average gray matter perfusion, and average diffusion tensor metrics along principal white matter pathways. We compared mean MRI values and variance at the old scanner location to multiple sessions at the new location using Bayesian multi-level regression models. K-fold cross validation allowed identification of important predictors. Whole-brain analyses were used to investigate any regional differences. Furthermore, we calculated within-subject coefficient of variation (wsCV), intraclass correlation coefficient (ICC), and dice similarity index (SI) of cortical segmentations across scanner relocation and within-site. Additionally, we estimated sample sizes required to robustly detect a 4% difference between two groups across MRI metrics. RESULTS: All global MRI metrics exhibited little mean difference and small variability (bar cortical gray matter perfusion) both across scanner relocation and within-site repeat. T1- and DTI-derived tissue metrics showed â€‹< â€‹|0.3|% mean difference and <1.2% variance across scanner location and <|0.4|% mean difference and <0.8% variance within the new location, with between-site intraclass correlation coefficient (ICC) â€‹> â€‹0.80 and within-subject coefficient of variation (wsCV) â€‹< â€‹1.4%. Mean cortical gray matter perfusion had the highest between-session variability (6.7% [0.3, 16.7], estimate [95% uncertainty interval]), and hence the smallest ICC (0.71 [0.44,0.92]) and largest wsCV (13.4% [5.4, 18.1]). No global metric exhibited evidence of a meaningful mean difference between scanner locations. However, surface area showed evidence of a mean difference within-site repeat (between S2 and S3). Whole-brain analyses revealed no significant areas of difference between scanner relocation or within-site. For all metrics, we found no support for a systematic difference in variance across relocation sites compared to within-site test-retest reliability. Necessary sample sizes to detect a 4% difference between two independent groups varied from a maximum of n â€‹= â€‹362 per group (cortical gray matter perfusion), to total gray matter volume (n â€‹= â€‹114), average fractional anisotropy (n â€‹= â€‹23), total gray matter volume normalized by intracranial volume (n â€‹= â€‹19), and axial diffusivity (n â€‹= â€‹3 per group). CONCLUSION: Cortical gray matter perfusion was the most variable metric investigated (necessitating large sample sizes to identify group differences), with other metrics showing substantially less variability. Scanner relocation appeared to have a negligible effect on variability of the global MRI metrics tested. This manuscript reports within-site test-retest variability to act as a tool for calculating sample size in future investigations. Our results suggest that when all other parameters are held constant (e.g., sequence parameters and MRI processing), the effect of scanner relocation is indistinguishable from within-site variability, but may need to be considered depending on the question being investigated.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Neuroimagem/normas , Substância Branca/diagnóstico por imagem , Adulto , Idoso , Imagem de Tensor de Difusão/instrumentação , Imagem de Tensor de Difusão/normas , Feminino , Humanos , Angiografia por Ressonância Magnética/instrumentação , Angiografia por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Neuroimagem/instrumentação , Reprodutibilidade dos Testes , Tamanho da Amostra
6.
Front Neurol ; 10: 391, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31105633

RESUMO

The extent to which Alzheimer neuropathology, particularly the accumulation of misfolded beta-amyloid, contributes to cognitive decline and dementia in Parkinson's disease (PD) is unresolved. Here, we used Florbetaben PET imaging to test for any association between cerebral amyloid deposition and cognitive impairment in PD, in a sample enriched for cases with mild cognitive impairment. This cross-sectional study used Movement Disorders Society level II criteria to classify 115 participants with PD as having normal cognition (PDN, n = 23), mild cognitive impairment (PD-MCI, n = 76), or dementia (PDD, n = 16). We acquired 18F-Florbetaben (FBB) amyloid PET and structural MRI. Amyloid deposition was assessed between the three cognitive groups, and also across the whole sample using continuous measures of both global cognitive status and average performance in memory domain tests. Outcomes were cortical FBB uptake, expressed in centiloids and as standardized uptake value ratios (SUVR) using the Centiloid Project whole cerebellum region as a reference, and regional SUVR measurements. FBB binding was higher in PDD, but this difference did not survive adjustment for the older age of the PDD group. We established a suitable centiloid cut-off for amyloid positivity in Parkinson's disease (31.3), but there was no association of FBB binding with global cognitive or memory scores. The failure to find an association between PET amyloid deposition and cognitive impairment in a moderately large sample, particularly given that it was enriched with PD-MCI patients at risk of dementia, suggests that amyloid pathology is not the primary driver of cognitive impairment and dementia in most patients with PD.

7.
Br J Radiol ; 91(1087): 20170593, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29537305

RESUMO

OBJECTIVE: To highlight specific instances when radial k-space acquisitions in MRI result in image artifacts and how to ameliorate such artifacts. METHODS: We acquired axial T2 weighted MR images on (1) the American College of Radiology (ACR) phantom and (2) a sedated sheep with rectilinear and multiblade radial k-space filling acquisitions. Images were acquired on four (2 × 1.5T and 2 × 3T) different MRI scanners. For the radial k-space acquisitions, we acquired images with and without motion correction. All images were visually inspected for the presence of artifact. RESULTS: Images collected via the conventional rectilinear method were of diagnostic quality and free of artifact. Both ACR and sheep images acquired with radial k-space acquisitions and motion correction suffered significant artifact at different slice locations, scan sessions and across all the four scanners. Severity of the artifact was associated with echo train length. However, the artifact was eliminated when motion correction was not employed. CONCLUSION: When little to no motion is present, the use of motion correction with radial k-space acquisitions can compromise image quality. However, image quality is quickly improved, and the artifact eliminated, by repeating the scan without motion correction or by using a conventional rectilinear alternative. Advances in Knowledge: By improving awareness and understanding of this artifact, MRI users will be able to adjust MRI protocols, resulting in more successful scanning sessions, better image quality, fewer call backs and increased diagnostic confidence.


Assuntos
Encéfalo/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Carneiro Doméstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...