Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Med Sci Monit ; 30: e944502, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38857196

RESUMO

BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P≤0.05 were considered significant. RESULTS HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 µm). Differences between subgroups for Ra and Rq values were significant (P≤0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. CONCLUSIONS Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.


Assuntos
Materiais Dentários , Polimento Dentário , Vapor , Esterilização , Propriedades de Superfície , Zircônio , Esterilização/métodos , Humanos , Polimento Dentário/métodos , Teste de Materiais/métodos , Restauração Dentária Permanente/métodos , Microscopia Eletrônica de Varredura/métodos
2.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762747

RESUMO

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Assuntos
Materiais para Moldagem Odontológica , Glutaral , Teste de Materiais , Polivinil , Siloxanas , Materiais para Moldagem Odontológica/química , Polivinil/química , Siloxanas/química , Fatores de Tempo , Glutaral/química , Desinfetantes de Equipamento Odontológico/química , Hipoclorito de Sódio/química , Desinfetantes/química , Clorexidina/química , Propriedades de Superfície , Humanos
3.
BMC Oral Health ; 24(1): 495, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671430

RESUMO

BACKGROUND: Dental casts made utilising digital workflow are becoming more common because to their speed and cost savings. However, studies on their dimensional accuracy over time with diverse designs are missing. OBJECTIVE: The aim of this in vitro study was to assess the dimensional stability of 3D-printed edentulous and fully dentate hollowed maxillary models with 50-micrometer resolution over 1 day, 14 days, and 28 days using surface matching software. METHODS: Scanned edentulous and fully dentate maxillary typodont models were used as references. The models were scanned by a desktop lab scanner of 15-micrometer accuracy (D900, 3Shape). Then, the files were used in designing software (Meshmixer, Autodesk) to create hollowed maxillary casts. Fifteen edentulous and 15 fully dentate (total of 30) models were printed using a DLP lab printer (Cara print 4.0, Kulzer). The 3D-printed models were scanned using the same desktop lab scanner of 15-micrometer accuracy at intervals of baseline days, 1 day, 14 days, and 28 days to assess the effect of aging (n = 120). The dimensional changes were quantified and compared using the root mean square (RMS) method, expressed in micrometres (µm). The study employed repeated measures analysis of variance (ANOVA) to assess and compare the root mean square (RMS) values across the variables. The data was analysed using SPSS (26, Chicago, Illinois, USA). RESULTS: The RMS of the edentulous models rapidly increased from a mean value of 0.257 at the beginning of the study to 0.384 after twenty-eight days. However, the mean RMS values for the dentate models did not change much over the four intervals. It varied only from 0.355 to 0.347. The mean values for edentulous patients increased from 0.014 to 0.029 during the period from baseline to twenty-eight days. However, the mean average values decreased for the dentate models from 0.033 to 0.014 during this period. By utilizing ANOVA, mean RMS values increased insignificantly till one day but significantly to fourteen and twenty-eight days. Dentate model mean values differed insignificantly across four intervals. Repeated measures ANOVA for combined and separated data showed no significant differences across edentulous, dentate, and total models over times. CONCLUSION: The study revealed changes in the dimensions of 3D-printed edentulous models over a span of 3 and 4 weeks. Caution should be applied when using 3D-printed dental master models for constructing definitive prostheses on edentulous models over a period of 3 to 4 weeks.


Assuntos
Maxila , Modelos Dentários , Impressão Tridimensional , Humanos , Maxila/anatomia & histologia , Fatores de Tempo , Software , Desenho Assistido por Computador , Técnicas In Vitro
4.
Technol Health Care ; 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37980583

RESUMO

BACKGROUND: Bonding between metal and ceramic is one of the most important aspects of a successful prosthesis. Various methods have been recommended for preparing the metal surface to enhance the bond between metal and ceramic including the use of a metal bonding agent. OBJECTIVE: This study aims to evaluate and compare the shear bond strength of the metal-ceramic (M-C) interface after combinations of various surface treatments including the application of a metal bonding agent. METHOD: 40 Ni-Cr alloy specimens were made and divided into 4 groups of 10 each based on the combination of surface treatments. Sandblasting, surface grinding, and Oxidation heat treatment (OHT) were performed on specimens from Group 1 (Control). In addition, Group 2 specimens received ultrasonic cleaning, Group 3 steam cleaning, and Group 4 metal bonding agent application. Following surface treatments on all specimens, porcelain build-up was performed, and shear bond strength was tested in a Digital Universal testing machine. The statistical tests used were independent t-test and ANOVA. RESULTS: Results revealed that Group 4 specimens had the highest mean value of shear bond strength of 39.087 MPa while Group 3 specimens showed the least mean shear bond strength of 18.154 MPa with highly statistically significant results (p< 0.001). CONCLUSION: The surface treatments and application of bonding agent to metal prior to porcelain application resulted in increased shear bond strength of the metal-ceramic interface.

5.
Med Sci Monit ; 29: e941654, 2023 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-37924203

RESUMO

BACKGROUND The aim of this study was to assess and compare the vertical/horizontal dimensions and occlusal accuracy of non-working/opposing casts obtained from three different impression materials and 3D print cast. MATERIAL AND METHODS Dentulous Master models simulating a case of a fixed dental prosthesis were mounted on an articulator (control group). Opposing mandibular casts obtained from three different impression materialsand 3-dimensional print constituted test groups , ,and , respectively. Three points, anterior vertical (AV), posterior vertical (PV), and anteroposterior (AP) were compared for dimensional accuracy among casts. Occlusal accuracy was analyzed on Medit Link software at 3 teeth (#13, #17, and #27). After calculating means for each group, the differences were calculated at probability value of P≤0.05 using the single-sample t test, ANOVA, and Tukey test. RESULTS The dimensions were significantly different from those of the mounted master models except in Gp AL(E) and Gp AL(F) at AV dimension and Gp AL(E) at AP dimension (P>0.05). A statistically significant difference of the error of means among the 4 tested groupswere detected only at 2 dimensions (AV and PV) between the Gp AL(E) and Gp 3D-C and between Gp AL(F) and Gp 3D-C groups. Other groups showed no significant differences. CONCLUSIONS The opposing casts obtained from the extended-pour alginate and alginate alternative impression materials showed higher occlusal accuracy compared to conventional alginate and 3D printed casts.


Assuntos
Modelos Dentários , Impressão Tridimensional , Humanos , Alginatos , Mandíbula , Software
6.
Med Sci Monit Basic Res ; 29: e941919, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37987528

RESUMO

BACKGROUND Replicating the 3-dimensional (3D) color of natural teeth in artificial substitutes is challenging. Fixed dental prosthodontics require aesthetic, color-stable provisional restorations. Recent milling and 3D printing digital manufacturing techniques offer improved outcomes. This study assesses color stability in various digital manufacturing methods, tapers, and aging effects on anterior provisional resin restorations. MATERIAL AND METHODS Two all-ceramic tooth preparations on typodont teeth with 10° and 20° tapers were converted into experimental dies. Forty temporary crowns were manufactured using 3D printing and computer-aided design/computer-aided manufacturing (milling). Within these 2 groups, 10 crowns were cemented using a regular and clear provisional cement. All samples were thermocycled to simulate clinical use of 6 months. Color difference formula (CIEDE2000) indicated changes between before and after cementation (ΔE00) and between after cementation and after thermocycling (ΔE00[II]). The color change was considered significant in terms of clinically perceptible (ΔE00 ≤0.62) and acceptable (ΔE00 ≤2.62) changes. One-way ANOVA (P value of less than 0.05) calculated overall differences, which were established using a Fisher post hoc test. RESULTS Crowns cemented with clear cement showed fewer color changes irrespective of the manufacturing technique or taper. Notably, only the 10° 3D-printed crown with clear cement had an imperceptible color change at the pre-/post-cementation phase. Meanwhile, the 10° and 20° milled crowns with regular cement exhibited unacceptable color changes after thermocycling. CONCLUSIONS For long­term temporization in the aesthetic zone, properly optimized 3D-printed provisional restorations cemented with clear cement had better color stability.


Assuntos
Colorimetria , Coroas , Teste de Materiais , Desenho Assistido por Computador , Cimentos de Ionômeros de Vidro
7.
J Clin Med ; 12(18)2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37762774

RESUMO

BACKGROUND: At present, the evidence regarding digital impressions' accuracy recorded by using digital scanners is lacking. This systematic review aimed to evaluate whether the type of scanning (intraoral/extraoral) affects the Accuracy of Digital Impressions. METHOD: Two independent reviewers performed a systematic search in the database both electronically and manually (PubMed, Ebsco HOST, the Cochrane Library, and Google Scholar) for articles published from 1 January 2010 to 1 December 2022. This study was registered with the International Prospective Register of Systematic Reviews (PROSPERO CRD42020188765) and followed the PRISMA statement. The question in focus was as follows: Does the type of scanning (intraoral or extraoral) affect the accuracy of digital impression? RESULTS: A total of 449 papers were obtained by searching electronically and manually. In total, 15 complete-text papers qualified for assessment based on eligibility criteria. After reading the full-text articles, five studies were excluded. Ten studies were selected for the qualitative analysis. The qualitative data reported that the accuracy of both types of scanners (intraoral and extraoral) lies within the range of clinical acceptability. Nevertheless, the intraoral scanners seem to be more accurate when compared to the extraoral scanners for a partial arch situation. CONCLUSIONS: Scanning type affects the accuracy of the digital impression. Various factors influence the scanning ability. Intraoral scanners seem to be more accurate compared to extraoral scanners for a partial arch situation. More studies comparing the accuracy of the intraoral scanner and extraoral scanner for a complete arch scan and in an in vivo study setting are needed.

8.
BMC Oral Health ; 23(1): 564, 2023 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-37574557

RESUMO

BACKGROUND: Developing efficient bonding techniques for orthodontic brackets and all-ceramic materials continues to pose a clinical difficulty. This study aimed to evaluate the shear bond strengths (SBS) of metal and ceramic brackets to various all-ceramic CAD-CAM materials, such as lithium disilicate CAD (LDS-CAD), polymer-infiltrated ceramic (PIC), zirconia-reinforced lithium silicate glass ceramic (ZLS), and 5YTZP zirconia after different surface treatments and thermal cycling. MATERIALS AND METHODS: The samples were divided into two groups to be bonded with ceramic and metal lower incisor brackets. Each group was subdivided into a control group devoid of any surface treatment, 10% HF acid (HFA) etching, ceramic etch & prime (MEP), Al2O3 air abrasion, and medium grit diamond bur roughening. After surface treatment, brackets were bonded with composite resin cement, thermal cycled, and tested for shear bond strength. The failed surfaces were evaluated with a digital microscope to analyse the type of failure. The data were statistically analysed using a one-way ANOVA and Tukey HSD tests at p < 0.05. RESULTS: The highest mean bond strengths were found with HFA etching in LDS-CAD (13.17 ± 0.26 MPa) and ZLS (12.85 0.52 MPa). Diamond bur recorded the lowest mean bond strength roughening across all the ceramic groups. There were significant differences in mean shear bond values per surface treatment (p < 0.001) and ceramic materials. CONCLUSION: Among the surface treatment protocols evaluated, HFA etching and MEP surface treatment resulted in enhanced bond strength of both ceramic and metal brackets to CAD-CAM all ceramic materials.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Humanos , Abrasão Dental por Ar , Colagem Dentária/métodos , Propriedades de Superfície , Cerâmica/química , Cimentos de Resina/química , Desenho Assistido por Computador , Diamante , Teste de Materiais , Resistência ao Cisalhamento
9.
Biomedicines ; 11(2)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36831026

RESUMO

Tobacco consumption in its different forms can affect the optical and surface properties of dental materials that are used in the oral cavity. Thus, the present study was conducted to evaluate the effects of two commercially available smokeless tobacco products on the color stability and surface roughness of denture base resins that were fabricated using three different techniques (CAD/CAM milling, 3D printing, and conventional heat polymerization). A total of 126 denture base resin specimens were fabricated using the three different manufacturing techniques (n = 42 each). Specimens from each group were further subdivided into three subgroups (n = 14 each) and immersed in three different immersion media (a khaini suspension, a tabbaq suspension, and artificial saliva). The differences in color and surface roughness were assessed according to data that were collected and statistically analyzed using SPSS version 24.0. The tabbaq smokeless tobacco was found to cause greatest changes in color and surface roughness; the effect was observed to be highest in the 3D-printed specimens followed by the conventional heat-polymerized and CAD/CAM milled specimens. The mean changes in color and surface roughness were the highest for the tabbaq smokeless tobacco followed by the khaini smokeless tobacco and the artificial saliva. Statistically significant (p-value < 0.05) differences were observed among all techniques and suspensions. We concluded that the mean changes in color and surface roughness were significantly higher for the 3D-printed dentures compared to the conventional heat-polymerized and CAD/CAM-milled dentures. Thus, the results of the present study strengthened the concept that tobacco in any form can lead to changes in the color and surface roughness of denture base materials.

10.
Biomedicines ; 11(2)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36831106

RESUMO

The aim of this study is to investigate the combined effect of a digital manufacturing technique (subtractive vs. additive), preparation taper (10° vs. 20° TOC), and finish line (chamfer vs. shoulder) on the marginal adaptation of temporary crowns following cementation with a compatible temporary cement. Four mandibular first molar typodont teeth were prepared for full coverage crowns with standard 4 mm preparation height as follows: 10° TOC with the chamfer finish line, 10° TOC with the shoulder finish line, 20° TOC with the chamfer finish line and 20° TOC with the shoulder finish line. Each of the four preparation designs were subdivided into two subgroups to receive CAD/CAM milled and 3D-printed crowns (n = 10). A total of 80 temporary crowns (40 CAD/CAM milled and 40 3D-printed) were cemented to their respective die using clear temporary recement in the standard cementation technique. The samples were examined under a stereomicroscope at ×100 magnification following calibration. Linear measurements were performed at seven equidistant points on each axial surface and five equidistant points on each proximal surface. One-way ANOVA analysis and Tukey HSD (Honestly Significance Difference) were performed. The best marginal fit was seen in group 8, while the poorest fit was noted in group 2. Shoulder finish lines and 10° TOC resulted in higher marginal gaps, especially in CAD/CAM milled group. The selection of 3D-printed crowns may provide a better marginal fit within the range of clinical acceptability. Marginal gaps were within clinical acceptability (50 and 120 µm) in all groups except group 2.

11.
Medicina (Kaunas) ; 59(2)2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36837611

RESUMO

Background and Objectives: Little information is available on the role of Vitamin D as a micro-nutrient deficiency with masticatory muscle efficiency and its effect on the function of removable prosthesis. The aim of this study was to evaluate the role of vitamin D on masticatory muscle activity among completely edentulous patients and its effect on the retention of removable complete dentures (RCDs). Materials and Methods: A non-randomized clinical control trial was conducted on completely edentulous patients (60.53 ± 7.01 years) in the Indian population between 2017 and 2019. Subjects were evaluated for temporomandibular disorders according to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD). Serum Vitamin D (S Vit D) levels, Ultrasonography (USG), and surface Electromyography (sEMG) readings of the masseter muscle were recorded at enrolment (Level 0), after 3 months of Vitamin D therapy (Level 3), and after consecutive 3 months of maintenance therapy, i.e., after 6 months from baseline (Level 6). The fabrication of new RCDs was done for all after the enrolment, and the retention of RCDs was assessed by asking a question regarding denture retention and asking respondents to mark their satisfaction on a 5-point Likert scale. Data were analysed using ANOVA, Paired'-test and Pearson correlation coefficients. A p-value less than 0.05 indicated a statistically significant association. Results: Between enrolment and a six-month follow-up, S Vit D levels showed an increase from 16.03 ± 5.68 ng/mL to 31.35 ± 9.28 ng/mL, showing an increase of 15.32 ± 9.38 ng/mL (95.57% rise). Statistically significant values were observed for USG and sEMG. Conclusions: Results showed that S Vit D affects masticatory muscle activity by improving its thickness and boosting its tonicity. Healthy muscles assist in the retention of RCDs, consequently aiding in mastication, speech, and phonetics, hence improving patient satisfaction. Clinical implication: Acknowledging the fact that the prevalence of Vitamin D deficiency is worldwide. We suggest Vitamin D therapy as a nutritional intervention among the elderly completely edentulous population, following dietary counselling, and consider Vitamin D therapy to be an adjunct to nutritional counselling for improving masticatory muscle activity and efficiency, which aids in RCD retention and stability. Consequently, improving oral health-related quality of life for individuals.


Assuntos
Boca Edêntula , Transtornos da Articulação Temporomandibular , Humanos , Idoso , Vitamina D , Qualidade de Vida , Prótese Total , Músculos da Mastigação/fisiologia , Vitaminas
12.
Polymers (Basel) ; 15(4)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36850239

RESUMO

BACKGROUND: Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp. This study aimed to examine the retentive forces and the fitting surface (inner surface) deformation of clasps made from PEEK and compare it with cobalt-chromium (Co-Cr) clasp. METHODS: Forty-two circumferential clasps (14 Co-Cr and 28 PEEK) were fabricated and divided into two groups with clasp undercuts (0.25 mm and 0.5 mm) with thicknesses of 1 mm and 1.5 mm. Each was examined for retentive forces after cycle test on its abutment for 360 cycles. Initial and final retentive forces were recorded. The fitting surface deformation was determined using 3-Matic research analysis software. RESULTS: The results revealed that highest mean initial retentive force was of Co-Cr clasps with 0.50 mm undercut 22.26 N (±10.15 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 3.35 N (±0.72 N) and highest mean final retentive force was the Co-Cr clasps with 0.50 mm undercut 21.40 N (±9.66 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 2.71 N (±0.47 N). PEEK clasps had a lower retentive force than Co-Cr clasps with 0.50 undercut. PEEK clasps (1.5 mm) at 0.25 mm undercut had the least deformation (35.3 µm). PEEK showed significantly less deformation (p ≤ 0.014) than Co-Cr. CONCLUSION: The deformation of PEEK clasps fitting surface was lower than Co-Cr clasps and retentive forces were close to the Co-Cr clasps, suggesting the use of PEEK as an aesthetic clasp option for RPD framework.

13.
Polymers (Basel) ; 15(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36772044

RESUMO

An accurate and dimensionally stable trial denture base is required for a successful denture. The aim of this in vitro study was to assess the dimensional stability of a light-activated urethane dimethacrylate (UDMA) visible light cure (VLC) denture base with three fabrication techniques and different curing cycles. Forty-five VLC denture base samples were divided evenly into three groups. Group A used a conventional fabrication technique with a curing cycle of 5 min. Group B used a modified fabrication technique with two 4-min curing cycles. Group C used a multi-step fabrication technique with three curing cycles (4 min, plus 4 min, plus 2 min). The samples were sectioned and observed under a stereomicroscope to measure the discrepancy between the sample and the master cast. The mean dimensional discrepancy (mm) at the molar region at mid-palate, after 24 h in Group A, B and C was 0.790 mm, 0.741 mm and 0.379 mm, respectively; at the right ridge crest, it was 0.567, 0.408 and 0.185, while at the left ridge crest it was 0.475, 0.331 and 0.125, respectively. Statistical analysis showed significantly different dimensional discrepancies among the groups at all three sites; right ridge crest (F = 93.54, p < 0.001), left ridge crest (F = 105.96, p < 0.001) and mid-palate (F = 125.53, p < 0.001). Within the limitations of this laboratory study, it can be concluded that the denture base using a multi-step fabrication technique with three curing cycles provides better adaptation than the conventional technique. The significance of the study is that clinicians should consider performing denture base fabrication using a multi-step technique to enhance adaptation and hence the stability of the dentures for patients.

14.
Technol Health Care ; 31(1): 247-258, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36031920

RESUMO

BACKGROUND: Advances in digital dentistry lead to use of three-dimensional (3D) printed resin denture teeth. Fracture toughness of these teeth must be assessed. OBJECTIVE: This study aimed to compare the chipping and indirect tensile fracture resistance of denture teeth fabricated by 3D printing technique with traditionally fabricated resin denture teeth. METHOD: Four groups (Gr) were made (n= 50/group): Gr-1 3D printed denture teeth (denture teeth; Formlabs Inc., Somerville, MA, USA), Gr-2 SR-Orthosit-PE (Ivoclar Vivadent AG), Gr-3 Portrait IPN (Dentsply Sirona), Gr-4 Pala Premium 8 (Heraeus Kulzer GmbH). Stereolithography 3D printing was used to create the methacrylate-based photopolymerized resin teeth models and remaining group teeth were collected commercially. A 1 mm/min chipping and indirect tensile fracture speed tests were carried out till fracture occurred. The data so obtained were statistically analysed using one-way analysis of variance with Tukey's honestly significant difference multiple comparisons test (p< 0.05). At the end of the test, the fractured areas of the specimens were evaluated by the chief researcher to assess the fracture pattern of the teeth. RESULTS: The indirect tensile fracture values of the 3D printed teeth were more than that of Pala Premium-8 and SR-Orthosit-PE but it was lower than that of Portrait IPN teeth. In chipping test, buccal chipping of the loaded cusp was seen in 3D printed resin without distortion and in indirect tensile test in 3D printed resin teeth, line of fracture emerges near the loading point propagates from the inner incline of both cusps and extends cervically, unlike in other groups where first deformation occurs then fracture. CONCLUSION: Prosthetic teeth fabricated by the 3D printing technique using printable resin material provide adequate fracture resistance as denture teeth.


Assuntos
Dentaduras , Impressão Tridimensional , Humanos , Teste de Materiais , Propriedades de Superfície
15.
PLoS One ; 17(7): e0271188, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35881572

RESUMO

BACKGROUND: High rates of non-prescription dispensing of antimicrobials have led to a significant increase in the antimicrobial overuse and misuse in Saudi Arabia (SA). The objective of this study was to evaluate the antimicrobial utilization following the enforcement of a new prescription-only antimicrobial dispensing policy in the community pharmacy setting in SA. METHODS: Data were extracted from the IQVIA database between May 2017 and May 2019. The antimicrobial utilization rates, based on sales, defined daily dose in grams (DDD), DDD/1000 inhabitants/day (DID), and antimicrobial-claims for the pre-policy (May 2017 to April 2018) and post-policy (June 2018 to May 2019) periods were assessed. RESULTS: Overall antimicrobial utilization declined slightly (~9-10%) in the post-policy versus pre-policy period (sales, 31,334 versus 34,492 thousand units; DDD, 183,134 versus 202,936), with higher claims (~16%) after policy implementation. There was a sudden drop in the utilization rate immediately after policy enforcement; however, the values increased subsequently, closely matching the pre-policy values. Utilization patterns were similar in both periods; penicillin was the most used antimicrobial (sales: 11,648-14,700-thousand units; DDD: 71,038-91,227; DID: 2.88-3.78). For both periods, the highest dip in utilization was observed in July (sales: 1,027-1,559 thousand units; DDD: 6,194-9,399), while the highest spike was in March/October (sales: 3,346-3,884 thousand units; DDD: 22,329-19,453). CONCLUSION: Non-prescription antimicrobial utilization reduced minimally following policy implementation in the community pharmacies across SA. Effective implementation of prescription-only regulations is necessary.


Assuntos
Anti-Infecciosos , Farmácias , Antibacterianos/uso terapêutico , Anti-Infecciosos/uso terapêutico , Penicilinas , Arábia Saudita
16.
Technol Health Care ; 30(6): 1435-1442, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35661036

RESUMO

BACKGROUND: The prime concern of an implant-supported prosthesis (ISP) is to maintain an optimal proximal contact tightness, which further maintains arch integrity, improves masticatory effectiveness, and minimizes peri-implantitis. OBJECTIVE: To investigate the loss of proximal contact tightness between single tooth implant-supported prosthesis and the adjacent natural teeth. METHODS: Forty patients treated by a single mandibular first molar ISP, aged between 18-50 years were selected. All were randomly allocated in Group I and Group II. Group I, 20 subjects who have received ISP without an insertion of Essix retainer, and Group II patients received an insertion with Essix retainer. The groups were subdivided into Subgroup A, B, and Subgroup C, D, in which A and C are control groups. To measure the tightness at proximal contact points, a digital force analyzer was used. Proximal contact tightness (PCT) was measured immediately after the placement of the prosthesis, 3 months, 6 months, and 1-year follow-up respectively, and the PCT values at end of 1 year were statistically evaluated. Statistical analysis was done, mean and standard deviation was calculated by independent sample t-test wit p< 0.05 as a statistically significant value. RESULTS: In Group I, towards the end of 1 year, 2.09 N (65.5%) and 1.50 N (53.1%) loss of PCT were found on mesial and distal contact areas respectively. In Group II, loss of PCT at mesial contact area was 0.87 N (28.9%) and at distal contact area was 1.77 N (53.3%), which is significantly less compared with the non-usage of Essix retainer (p< 0.05). CONCLUSION: The usage of Essix retainer, PCT increases especially on the mesial contact area. The frequency of contact loss was decreased. Thus, to minimize the loss of proximal contact the usage of Essix retainer is recommended.


Assuntos
Implantes Dentários , Adolescente , Adulto , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Gravitação , Fenômenos Mecânicos
17.
Children (Basel) ; 9(3)2022 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-35327689

RESUMO

Diabetes affects the developing enamel by altering the mineralization process, which can have a detrimental effect on oral health. The objectives of this study were to examine the ultrastructure and composition of surface enamel in primary teeth of diabetic children and its clinical implications. Hundred extracted primary teeth from diabetic children (Test group: n = 50) and healthy children (Control group: n = 50), between 6 and 12 years of age, were subjected to scanning electron microscopy to qualitatively examine the enamel surface. Energy dispersive X-ray (EDX) analysis was performed to investigate the mass percentage of calcium (Ca) and phosphorous (P) in the surface enamel. Ultrastructural aberrations of surface enamel were observed in the test group teeth. Additionally, prism perforations were seen at the junction of rod and inter-rod enamel and the prisms were loosely packed. An even aprismatic layer of surface enamel was evident in the control group teeth. There was a statistically significant difference (p < 0.05) of Ca and P mass percentage between the test and control group teeth. The mean mass percentage rates of Ca and P were 33.75% and 16.76%, respectively. A poor surface characteristic and elemental composition of the enamel surface of primary teeth is observed in diabetic children. Therefore, appropriate caries preventive measures are mandatory to maintain the structural integrity of the tooth in these patients.

19.
Materials (Basel) ; 15(2)2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35057232

RESUMO

The improvement of the tensile strength of zirconia crowns after the application of commercially available desensitizers can provide added advantages for the durability and strength of zirconia prostheses. We assessed the retention of zirconia crowns when Gluma, Shield Force Plus, and Telio CS desensitizers were used with resin luting cement. Four groups with ten specimens each (n = 10) were considered as Group 1 (Control group, with no desensitizer application before crown cementation with resin cement) and Groups 2, 3, and 4 (with a single coat of Gluma dentin desensitizer, Telio CS desensitizer, or Shield Force Plus desensitizer applied before crown cementation, respectively). Thermocycling was then carried out, and each group was tested to determine the associated retentive forces and type of failure. The data were statistically analyzed, which showed that the mean tensile-strength values were significantly higher in Group 2 (p-value = 0.001), Group 3 (p-value = 0.027), and Group 4 (p-value = 0.014), when compared with the Control group. Clinicians should consider the application of any of these three desensitizers, as they can successfully abate dentin hypersensitivity after tooth preparation, as well as increase the durability and strength of the zirconia prosthesis.

20.
Materials (Basel) ; 14(24)2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34947142

RESUMO

Conventional osteotomy techniques can, in some cases, induce higher stress on bone during implant insertion as a result of higher torque. The aim of the present study was to evaluate and compare the stress exerted on the underlying osseous tissues during the insertion of a tapered implant using different osteotomy techniques through a dynamic finite element analysis which has been widely applied to study biomedical problems through computer-aided software. In three different types of osteotomy techniques, namely conventional (B1), bone tap (B2), and countersink (B3), five models and implants designed per technique were prepared, implant insertion was simulated, and stress exerted by the implant during each was evaluated. Comparison of stress scores on the cortical and cancellous bone at different time points and time intervals from initiation of insertion to the final placement of the implant was made. There was a highly statistically significant difference between B1 and B2 (p = 0.0001) and B2 and B3 (p = 0.0001) groups. In contrast, there was no statistically significant difference in the stress scores between B1 and B3 (p = 0.3080) groups at all time points of implant placement. Overall, a highly significant difference was observed between the stresses exerted in each technique. Within the limitations of our study, bone tap significantly exerted lesser stresses on the entire bone than conventional and countersink type of osteotomy procedures. Considering the stress distribution at the crestal region, the countersink showed lower values in comparison to others.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...