Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Craniofac Surg ; 33(5): 1479-1483, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34907951

RESUMO

OBJECTIVE: To evaluate the surgical accuracy of positioning the maxilla in patients with skeletal class II malocclusion using computer-aided design and computer-aided manufacturing (CAD/ CAM)-assisted orthognathic surgery. MATERIALS AND METHODS: The samples consisted of 10 patients with skeletal class II malocclusion, whose cone-beam computed tomographys taken before and immediately after surgery were available and who underwent bimaxillary orthognathic surgery by a single surgeon using Le Fort I osteotomy and bilateral sagittal split ramus osteotomy at the Department of Oral and Maxillofacial Surgery, Seoul National University Dental Hospital, Seoul, South Korea between January 2018 and December 2019. After virtual surgical planning was performed using the FACEGIDE system (Korea), surgical cutting guides, intermediate splints, and custom-made titanium mini-plates were fabricated using CAD/CAM technique. Using 8 landmarks (anterior nasal spine, point A, #16, #13, contact point between #11 and #21, #23, #26, posterior nasal spine), the mean differences between the virtually planned (Virtual) and actual postsurgical position of the maxilla (Actual) in the three-dimensional coordinates (ΔActual-Virtual) and their mean absolute deviations were investigated. RESULTS: The mean differences of 8 landmarks were 0.42 mm left side movement in the transverse coordinate, 0.15 mm forward movement in the sagittal coordinate and 0.10 mm downward movement in the vertical coordinate. Their mean absolute deviations were 0.98, 0.67, and 0.62 mm in the sagittal, vertical, and transverse coordinates, respectively. CONCLUSIONS: Since the mean difference was less than 0.5 mm and the range of error was less than 1.0 mm, CAD/CAM-assisted orthognathic surgery might have a high degree of surgical accuracy and clinical relevance in the positioning of the maxilla.


Assuntos
Má Oclusão , Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Cirurgia Assistida por Computador , Cefalometria/métodos , Desenho Assistido por Computador , Humanos , Imageamento Tridimensional/métodos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Procedimentos Cirúrgicos Ortognáticos/métodos , Osteotomia de Le Fort/métodos , Cirurgia Assistida por Computador/métodos
2.
J Craniofac Surg ; 32(1): e92-e94, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33186280

RESUMO

ABSTRACT: Systemic sclerosis is a complex autoimmune connective tissue disease of unknown cause that causes sclerosis and inflammation of the skin and subcutaneous tissue. Sclerosis involving the face can lead to microstomia, leading to difficulties with mastication, phonation, and oral hygiene. Although many agents have been used to treat internal organ involvement, they often have compromised efficacy on cutaneous manifestation including facial dermal sclerosis. In this case presentation, we will introduce a surgical technique to correct scleroderma-induced microstomia.


Assuntos
Microstomia , Escleroderma Sistêmico , Humanos , Microstomia/etiologia , Microstomia/cirurgia , Pescoço , Escleroderma Sistêmico/complicações , Pele , Retalhos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...