Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Environ Res ; 95(11): e10942, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37872103

RESUMO

The ceramic filter amended with iron (Fe) has proven to be a potential low-cost method for arsenic (As) removal from groundwater. The presence of Fe, phosphate (P), and silicate (Si) significantly affects the As removal efficiency of the ceramic filter, which has not been passably investigated. The present research aimed to examine the effect of Fe, P, and (or) Si presence as single or in combination on As (III) removal from synthetics groundwater by a low-cost iron amended ceramic filter (IACF). Laboratory-scale filtration experiments at different compositions of Fe, P, Si, and As (III) were conducted by the IACF fabricated with a ceramic candle and iron netting box. Fe (II) in synthetic groundwater positively impacted As (III) removal. At a concentration of 2 mg/L of Fe (II), the As levels in the effluent decreased to less than the maximum contamination level (MCL) of 50 µg/L. Groundwater P concentration needed less than 3 mg/L or Si concentrations required less than 35 mg/L to effectively reduce As (III) to below the MCL at 5 mg/L of groundwater Fe (II). The cumulative effect of P and Si on As removal was found to be more significant than distinct contributions. The presence of 2 mg/L P and 35 mg/L or higher Si in the groundwater cumulatively reduced the As removal performance from 92% to 63%, and the MCL was not met. The negative impact of P and Si on As (III) removal followed the order of (P + Si) > P > Si. P competed with As for adsorption sites during the process, while Si inhibited the Fe release and floc formation, significantly reducing As removal performance. The study findings can potentially contribute to optimizing IACF as a low-cost method for As removal from groundwater.


Assuntos
Arsênio , Água Subterrânea , Poluentes Químicos da Água , Purificação da Água , Ferro , Fosfatos , Purificação da Água/métodos , Poluentes Químicos da Água/análise , Silicatos
2.
Membranes (Basel) ; 13(5)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37233537

RESUMO

Humic, protein, and polysaccharide substances have been recognized as significant types of foulants in membrane systems. Despite the remarkable amount of research that has been performed on the interaction of these foulants, particularly humic and polysaccharide substances, with inorganic colloids in RO systems, little attention has been paid to the fouling and cleaning behavior of proteins with inorganic colloids in UF membranes. This research examined the fouling and cleaning behavior of bovine serum albumin (BSA) and sodium alginate (SA) with silicon dioxide (SiO2) and α-aluminum oxide (Al2O3) in individual and combined solutions during dead-end UF filtration. The results showed that the presence of SiO2 or Al2O3 in water alone did not cause significant fouling or a flux decline in the UF system. However, the combination of BSA and SA with inorganics was observed to have a synergistic effect on membrane fouling, in which the combined foulants caused higher irreversibility than individual foulants. Analysis of blocking laws demonstrated that the fouling mechanism shifted from cake filtration to complete pore blocking when the combined organics and inorganics were present in water, which resulted in higher BSA and SA fouling irreversibility. The results suggest that membrane backwash needs to be carefully designed and adjusted for better control of BSA and SA fouling with SiO2 and Al2O3.

3.
Heliyon ; 9(4): e14846, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37025773

RESUMO

Fractal dimension unlike topological dimension is (usually) a non-integer number which measures complexity, roughness, or irregularity of an object with respect to the space in which the set lies. It is used to characterize highly irregular objects in nature containing statistical self-similarity such as mountains, snowflakes, clouds, coastlines, borders etc. In this article, box dimension (a version of fractal dimension) of the border of Kingdom of Saudi Arabia (KSA) is computed using a multicore parallel processing algorithm based on the classical box-counting method. A power law relation is obtained from numerical simulations which relates the length of the border with the scale size and provides a very close estimate of the actual length of the KSA border within the scaling regions and scaling effects on the length of KSA border are considered. The algorithm presented in the article is shown to be highly scalable and efficient and the speedup of the algorithm is computed using Amdahl's and Gustafson's laws. For simulations, a high performance parallel computer is employed using Python codes and QGIS software.

4.
Artigo em Inglês | MEDLINE | ID: mdl-35742631

RESUMO

Extensive construction augmenting the infrastructure and real estate projects underpin Saudi Arabia's Vision 2030 of sustainable cities. A part of this struggle involves the transformation of the existing infrastructure together with new construction, which generates a large amount of construction and demolition waste (CDW). In the absence of a structured life cycle assessment (LCA) framework, the waste management companies are planning future scenarios (phased expansions of material recovery facilities to improve the recycling rate) primarily on economic grounds. This study assesses the environmental impacts of the existing and planned CDW management practices of the Saudi Investment Recycling Company in Riyadh City by dint of LCA. Impact 2002+ performs life cycle impact assessment of the base case (45% recycling), four treatments (61, 76, 88, and 100% recycling), and zero waste scenarios. The study demonstrates the benefits of current CDW (mixed soil, concrete blocks, clay bricks, glazed tiles, and asphalt) recycling in terms of avoided impacts of non-renewable energy, global warming, carcinogens, non-carcinogens, and respiratory inorganics potentially generated by landfilling. For the treatment scenario of 100% recycling, CDW conversion into a wide range of aggregates (0-50 mm) can replace 10-100% virgin aggregates in backfilling, precast concrete manufacturing, encasements and beddings of water mains and sewers, manholes construction, non-load bearing walls, and farm-to-market roads. To achieve long-term economic and environmental sustainability, municipalities need to improve source segregation, handling, and storage practices to enhance the existing (45%) recycling rate to 100% in the next five years and approach the zero-waste scenario by 2030. The findings of the present study motivate the generators for source reduction as well as encourage the recycling companies and concerned organizations in the continuous performance improvement of the CDW management systems across Saudi Arabia on environmental grounds, as an addition to the perceived economic benefits.


Assuntos
Indústria da Construção , Gerenciamento de Resíduos , Animais , Materiais de Construção , Resíduos Industriais , Estágios do Ciclo de Vida , Reciclagem , Arábia Saudita
5.
Environ Manage ; 67(2): 324-341, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33410919

RESUMO

Water utilities in arid regions deal with multifaceted issues of natural groundwater contamination, high treatment costs, and low water rates. These utilities rely on intermittent supplies resulting in numerous water quality failures at source, treatment, distribution, and in-house plumbing systems. The present research presents an inclusive risk assessment methodology for managing water quality from source to tap. Three-year monitoring data for turbidity, TDS, pH, iron, ammonia, nitrates, residual chlorine, Coliform group, E. coli, and Fecal Streptococci identified the root causes of failures. The cause-effect relationships in the form of a fault tree were solved using multiple failure modes and effect analysis (FMEA) to handle both the Boolean operations. The fuzzy sets addressed the uncertainties associated with data limitations in calculating exceedance probabilities (Pe) and vagueness in expert opinion for subjective evaluation of severity and detectability. The methodology was applied on a smaller system serving 18,000 consumers in Qassim, Saudi Arabia. Potable supplied water underwent reoccurrence of TDS (Pe = 20%), turbidity (Pe = 10%), and Fe (Pe = 2%) failures in distribution that further increased up to 44%, 33%, and 11% at the consumer end. The Pe for residual chlorine failure soared up to 89%. Economic controls reduced the cumulative risk to 50%, while the shift to continuous supply can limit the remaining failures under the acceptable risk. The framework will help utilities manage water quality in intermittent systems from source to tap in Saudi Arabia, the Gulf, and elsewhere.


Assuntos
Água Potável , Abastecimento de Água , Escherichia coli , Medição de Risco , Qualidade da Água
6.
Environ Pollut ; 272: 115977, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33172698

RESUMO

Groundwater in several parts of the world, particularly in developing countries, has been contaminated with Arsenic (As). In search of low-cost As removal methods, the biological oxidation of As(III) and Fe(II) followed by co-precipitation requires detailed investigation for the practical implementation of this technology. The present study investigated the biological oxidation of As(III) and Fe(II) through a combination of laboratory experiments and reactive transport modeling. Batch experiments were conducted to evaluate the As(III) oxidation by Fe-oxidizing bacteria, mainly Leptothrix spp. A fixed-bed down-flow biological column containing inexpensive and readily available coconut husk support media was used to evaluate the combined removal of As(III) and Fe(II) from synthetic groundwater. Oxidation and co-precipitation processes effectively reduced the concentration of As(III) from 500 µg/L to < 10 µg/L with a hydraulic retention time of 120 min. A one-dimensional reactive transport model was developed based on the microbially mediated biochemical reactions of As(III) and Fe(II). The model successfully reproduced the observed As(III) and Fe(II) removal trends in the column experiments. The modeling results showed that the top 20 cm aerobic layer of the column played a primary role in the microbial oxidation of Fe(II) and As(III). The model calibration identified the hydraulic residence time as the most significant process parameter for the removal of Fe and As in the column. The developed model can effectively predict As concentrations in the effluent and provide design guidelines for the biological treatment of As. The model would also be useful for understanding the biogeochemical behavior of Fe and As under aerobic conditions.


Assuntos
Arsênio , Água Subterrânea , Poluentes Químicos da Água , Cocos , Ferro , Oxirredução , Poluentes Químicos da Água/análise
7.
J Environ Manage ; 278(Pt 1): 111548, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33126200

RESUMO

Current microalgal based photobioreactors focus on the secondary treated effluent while limited researches attempted for treating the raw domestic wastewater. This study aimed to assess the microalgal biomass production, removal performance, and fouling characteristics of microalgal membrane bioreactors (MMBRs) for treating synthetic wastewater under different conditions of organic loading rate (OLR) and hydraulic residence time (HRT). The 12h/12 h dark/light cycle continuous experiments were performed for four MMBRs at different OLRs and three MMBRs at different HRTs. Results showed that microalgal biomass production rate (as TSS and chlorophyll-a) decreased with increasing OLR and increased with decreasing of HRT. Regardless of the OLR and HRT conditions, MMBRs can achieve up to 94% organic removal by bacterial oxidation without external aeration. Total nitrogen (TN) and total phosphorus (TP) removals were significantly decreased with increasing OLR. Highest TN removal (68.4%) achieved at the OLR of 0.014 kg/(m3 d) which was reduced to 58.1% at 0.028 kg/(m3 d). Removals of total phosphorous significantly decreased from 48.2% to 37.7% with an increase in OLR from 0.011 to 0.014 kg/(m3 d). TN removal was reduced at shorten HRT (2 d), while, the effect of HRT was found insignificant at higher HRT. An effective removal of P can only be achieved at higher HRTs, i.e., 7 days. OLR up to 0.014 kg/(m3 d) and 2 days HRT was found suitable for maintaining the fouling frequency at an optimal level of 0.016/d. Overall the OLR and HRT need to be carefully selected to achieve optimal efficiency of MMBR. The results of this study provide guidelines for designing the microalgal-based membrane bioreactors for the treatment of domestic wastewater.


Assuntos
Microalgas , Purificação da Água , Reatores Biológicos , Membranas , Eliminação de Resíduos Líquidos , Águas Residuárias
8.
Chemosphere ; 226: 668-677, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30959451

RESUMO

This study investigates chemical cleaning mechanisms of a tubular ceramic UF membrane. The effect of cleaner type (ozone (O3), sodium hypochlorite (NaOCl) and sodium hydroxide (NaOH)), clean in place (CIP) pH (11 vs. 12), and cleaning sequence on the removal of irreversible fouling of hydrophobic (humic acids) and hydrophilic (alginate with and without calcium (alginate + Ca+2 and alginate - Ca+2, respectively)) NOM fractions were investigated. Results showed that different NOM types responded differently to chemical cleaning. Alginate-Ca+2 and humic acids were equivalently removed by NaOCl or NaOH whereas a lower cleaning efficiency of alginate + Ca+2 was observed. Increasing the pH of NaOCl and NaOH CIP increased the removal of the chemically reversible fouling index (UMFIcr). The efficiency of NaOCl was always lower than that of NaOH at the same pH, which was attributed to surface tension (λ) differences in the CIP water and potential differences in cleaning mechanism. The ceramic UF CIP cleaning using O3 (0.50 mg O3/mgC) for 1 h demonstrated higher cleaning efficiency for humic acids and alginate ±â€¯Ca+2, (%UMFIcr > 98%), than NaOCl or NaOH alone (%UMFIcr>80%). The O3 CIP was as effective as 4 h cleaning using a sequential NaOH/NaOCl or combined NaOCl + NaOH CIP.


Assuntos
Cerâmica/química , Detergentes/química , Ozônio/química , Ultrafiltração/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...