Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 7(42): 38094-38104, 2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36312388

RESUMO

In this paper, a terahertz (THz) metamaterial absorber (MTMA), incorporating surface Pythagorean tree fractal resonators, was designed and experimentally fabricated on the flexible substrate of polyethylene terephthalate. The design presented two peaks with strong absorption of more than 97% at 0.49 and 0.69 THz. The dual-band absorption peaks were seen to be shifted with the change in the refractive index of the surrounding medium, with a corresponding sensitivity of 0.0968 and 0.1182 THz/RIU. The spectral shift of the reflection resonance dip was utilized as an assessment index to evaluate the sensing performance of the new structure, and it was found to be 2.08 and 2.98 for the two resonance peaks, respectively. It was observed that the proposed structure acted as an epsilon negative material at the first resonance and as a mu negative material at the second resonance. Further investigations on the electric field, magnetic field, and surface current distributions were carried out to elaborate on the absorption characteristics at various resonance frequencies. The proposed sensor is a highly sensitive MTMA which can be used to investigate the interaction of matter with THz waves.

2.
Biosensors (Basel) ; 12(10)2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36290965

RESUMO

Microstrip patch antennas have been used in many applications since their appearance. Despite their great promise, their narrow bandwidth and the loss at high-frequency bands have limited their usage in medical applications. This work proposes a developed low-cost microstrip patch antenna suitable for microwave imaging (MWI) applications within the wideband frequency range. The proposed antenna is loaded with an artificial magnetic conductor (AMC) to improve the antenna performance. The simulated results obtained using computer simulation technology (CST) indicate that the presence of the AMC has improved the frequency selectivity of the antenna at 8.6 GHz with a peak realized gain of 9.90443 dBi and 10.61 dBi for simulated and measured results, respectively. The proposed microstrip antenna has been fabricated to validate the simulated results, and its performance is tested experimentally. Additionally, the fidelity factor of face-to-face (FtF) and side-by-side (SbS) scenarios have been presented. The breast phantom models with a tumor and the antenna operating as a transceiver have been numerically simulated for the application of cancer tumor cell detection. The work will have a significant impact on the design of electromagnetic biosensors.


Assuntos
Neoplasias da Mama , Corpo Humano , Humanos , Feminino , Simulação por Computador , Desenho de Equipamento , Mama , Neoplasias da Mama/diagnóstico
3.
Materials (Basel) ; 15(18)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36143675

RESUMO

A new design of a triple band perfect metamaterial absorber based on Pythagorean fractal geometry is proposed and analyzed for terahertz sensing applications. The proposed design showed an enhanced sensing performance and achieved three intensive peaks at 33.93, 36.27, and 38.39 THz, corresponding to the absorptivity of 98.5%, 99.3%, and 99.6%, respectively. Due to the symmetrical nature of the recommended design, the structure exhibited the characteristics of independency on the incident wave angles. Furthermore, a parametric study was performed to show the effects of the change in substrate type, resonator material, and substrate thickness on the absorption spectrum. At a fixed analyte thickness (0.5 µm), the resonance frequency of the design was found to be sensitive to the refractive index of the surrounding medium. The proposed design presented three ultra-sensitive responses of 1730, 1590, and 2050 GHz/RIU with the figure of merit (FoM) of 3.20, 1.54, and 4.28, respectively, when the refractive index was changed from 1.0 to 1.4. Additionally, the metamaterial sensor showed a sensitivity of 1230, 2270, and 1580 GHz/µm at the three resonance frequencies, respectively, when it was utilized for the detection of thickness variation at a fixed analyte refractive index (RI) of 1.4. As long as the RI of the biomedical samples is between 1.3 and 1.4, the proposed sensor can be used for biomedical applications.

4.
Sensors (Basel) ; 20(3)2020 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-32050710

RESUMO

In this paper, a new metamaterials-based hypersensitized liquid sensor integrating omega-shaped resonator with microstrip transmission line is proposed. Microwave transmission responses to industrial energy-based liquids are investigated intensively from both numerical and experimental point of view. Simulation results concerning three-dimensional electromagnetic fields have shown that the transmission coefficient of the resonator could be monitored by the magnetic coupling between the transmission line and omega resonator. This sensor structure has been examined by methanol-water and ethanol-water mixtures. Moreover, the designed sensor is demonstrated to be very sensitive for identifying clean and waste transformer oils. A linear response characteristic of shifting the resonance frequency upon the increment of chemical contents/concentrations or changing the oil condition is observed. In addition to the high agreement of transmission coefficients (S21) between simulations and experiments, obvious resonant-frequency shift of transmission spectrum is recognized for typical pure chemical liquids (i.e., PEG 300, isopropyl alcohol, PEG1500, ammonia, and water), giving rise to identify the type and concentration of the chemical liquids. The novelty of the work is to utilize Q factor and minimum value of S21 as sensing agent in the proposed structure, which are seen to be well compatible at different frequencies ranging from 1-20 GHz. This metamaterial integrated transmission line-based sensor is considered to be promising candidate for precise detection of fluidics and for applications in the field of medicine and chemistry.

5.
Materials (Basel) ; 13(1)2019 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-31905854

RESUMO

A broadband coplanar waveguide (CPW)-fed monopole antenna based on conventional CPW-fed integration with an organic solar cell (OSC) of 100% insolation is suggested for Ku band satellite communication. The proposed configuration was designed to allow for 100% insolation of the OSC, thereby improving the performance of the antenna. The device structure was fabricated using a Leiterplatten-Kopierfrasen (LPKF) prototyping Printed circuit board (PCB) machine, while a vector network analyzer was utilized to measure the return loss. The simulated results demonstrated that the proposed antenna was able to cover an interesting operating frequency band from 11.7 to 12.22 GHz, which is in compliance with the International Telecommunication Union (ITU). Consequently, a 3 GHz broadband in the Ku band was achieved, along with an enhancement in the realized gain of about 6.30 dB. The simulation and experimental results showed good agreement, whereby the proposed structure could be specifically useful for fixed-satellite-services (FSS) operating over the frequency range from the 11.7 to 12.22 GHz (downlink) band.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...