Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Microbiol ; 54(4): 1148-51, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26842707

RESUMO

We compared the newly approved BacT/Alert Virtuo blood culture system to the BacT/Alert 3D system using 115 clinical bacterial and fungal isolates in 784 simulated blood culture bottles. The time to detection was reduced by roughly 20% in the Virtuo system (P< 0.0001) while the detection rate did not differ.


Assuntos
Bacteriemia/diagnóstico , Bactérias/isolamento & purificação , Hemocultura/métodos , Fungemia/diagnóstico , Leveduras/isolamento & purificação , Humanos , Sensibilidade e Especificidade , Fatores de Tempo
2.
PLoS One ; 10(11): e0142398, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26554930

RESUMO

Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.


Assuntos
Bactérias Anaeróbias/isolamento & purificação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias Anaeróbias/classificação , Bactérias Anaeróbias/crescimento & desenvolvimento , Humanos
3.
J Med Microbiol ; 64(11): 1346-1352, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26361761

RESUMO

Rapid identification of bacteria from blood cultures enables early initiation of appropriate antibiotic treatment in patients with bloodstream infections (BSI). The objective of the present study was to evaluate the use of matrix-associated laser desorption ionization-time of flight (MALDI-TOF) MS after a short incubation on solid media for rapid identification of bacteria from positive blood culture bottles. MALDI-TOF MS was performed after 2.5 and 5.5 h plate incubation of samples from positive blood cultures. Identification scores with values ≥ 1.7 were accepted as successful identification if the results were confirmed by conventional methods. Conventional methods included MALDI-TOF MS, Vitek 2, and diverse biochemical and agglutination tests after overnight culture. In total, 515 positive blood cultures with monomicrobial bacterial growth representing one blood culture per patient were included in the study. There were 229/515 (44.5%) and 286/515 (55.5%) blood culture bottles with Gram-negative bacteria (GNB) and Gram-positive bacteria (GPB), respectively. MALDI-TOF MS following short-term culture could accurately identify 300/515 (58.3%) isolates at 2.5 h, GNB being identified in greater proportion (180/229; 78.6%) than GPB (120/286; 42.0%). In an additional 124/515 bottles (24.1%), identification was successful at 5.5 h, leading to accurate identification of bacteria from 424/515 (82.3%) blood cultures after short-term culture. Interestingly, 11/24 of the isolated anaerobic bacteria could be identified after 5.5 h. The present study demonstrates, in a large number of clinical samples, that MALDI-TOF MS following short-term culture on solid medium is a reliable and rapid method for identification of bacteria from blood culture bottles with monomicrobial bacterial growth.


Assuntos
Bacteriemia/microbiologia , Bactérias/isolamento & purificação , Técnicas de Tipagem Bacteriana/métodos , Sangue/microbiologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bacteriemia/diagnóstico , Bactérias/química , Bactérias/classificação , Bactérias/crescimento & desenvolvimento , Técnicas de Tipagem Bacteriana/instrumentação , Humanos
4.
J Clin Microbiol ; 53(2): 710-2, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25520440

RESUMO

We evaluated the clinical performance of the FilmArray blood culture identification (BCID) panel in the identification of microorganisms from positive blood culture bottles inoculated with sterile body fluids. All organisms included in the FA BCID panel were accurately identified in 84/84 (100%) and 18/24 (75%) samples with mono- and polymicrobial growth, respectively.


Assuntos
Infecções Bacterianas/diagnóstico , Líquidos Corporais/microbiologia , Candidíase/diagnóstico , Técnicas Microbiológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Humanos , Reação em Cadeia da Polimerase Multiplex/métodos , Sensibilidade e Especificidade , Fatores de Tempo
6.
J Clin Microbiol ; 52(9): 3230-6, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24951811

RESUMO

In this study, we investigated the performance of the FilmArray and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) in identifying microorganisms from blood culture (BC) bottles prior to positivity. First, we used simulated BacT/Alert FA Plus BC bottles with five each for Escherichia coli and Staphylococcus aureus isolates. The FilmArray identified all 10 isolates before BC positivity with 9/10 at 5 h and 1 at 7.5 h after incubation in the BC system. MALDI-TOF MS failed to identify the isolates prior to positivity. When the bottles were incubated for 2.5 h at room temperature (RT) before we put them into the BC system, the FilmArray identified 6/10 at 2.5 h and the remaining 4 at 5 h. Finally, we tested simulated BC bottles after incubation at RT. Interestingly, 9/10 isolates were identified with the FilmArray after 8 h of incubation at RT. Second, we studied clinical BC bottles in quadruplicate. When three-fourths of the parallel bottles signaled positive, the FilmArray was run on the fourth nonsignaled bottle and was found to be positive in 14/15 such cases. Third, we analyzed the performance of the FilmArray in the identification of microorganisms from clinical BC bottles before incubation in the system. Two milliliters of broth from 400 BC bottles was collected after arrival at the laboratory and stored at -70°C. Sixteen bottles later signaled positive in the system. When the frozen broth from these bottles was analyzed, the FilmArray identified all the microorganisms in 8/16 bottles prior to incubation in the BC system. This study shows that the FilmArray can identify microorganisms from BC bottles prior to positivity and in some cases even prior to incubation in the BC system.


Assuntos
Sangue/microbiologia , Técnicas Microbiológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase Multiplex/métodos , Sepse/diagnóstico , Sepse/microbiologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias/classificação , Bactérias/isolamento & purificação , Candida/classificação , Candida/isolamento & purificação , Humanos , Temperatura , Fatores de Tempo
7.
J Clin Microbiol ; 51(12): 4130-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24088863

RESUMO

The FilmArray platform (FA; BioFire, Salt Lake City, UT) is a closed diagnostic system allowing high-order multiplex PCR analysis with automated readout of results directly from positive blood cultures in 1 h. In the present study, we evaluated the clinical performance of the FilmArray blood culture identification (BCID) panel, which includes 19 bacteria, five yeasts, and three antibiotic resistance genes. In total, 206 blood culture bottles were included in the study. The FilmArray could identify microorganisms in 153/167 (91.6%) samples with monomicrobial growth. Thirteen of the 167 (7.8%) microorganisms were not covered by the FilmArray BCID panel. In 6/167 (3.6%) samples, the FilmArray detected an additional microorganism compared to blood culture. When polymicrobial growth was analyzed, the FilmArray could detect all target microorganisms in 17/24 (71%) samples. Twelve blood culture bottles that yielded a positive signal but showed no growth were also negative by FilmArray. In 3/206 (1.5%) bottles, the FilmArray results were invalid. The results of the FilmArray were reproducible, as demonstrated by the testing and retesting of five bottles in the same day and a longitudinal follow-up of five other blood cultures up to 4 weeks. The present study shows that the FilmArray is a rapid identification method with high performance in direct identification of bacteria and yeasts from positive blood culture bottles.


Assuntos
Bacteriemia/diagnóstico , Bactérias/isolamento & purificação , Sangue/microbiologia , Fungemia/diagnóstico , Técnicas Microbiológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Leveduras/isolamento & purificação , Bacteriemia/microbiologia , Bactérias/classificação , Bactérias/genética , Fungemia/microbiologia , Humanos , Reprodutibilidade dos Testes , Leveduras/classificação , Leveduras/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...