1.
Radiat Prot Dosimetry ; 199(15-16): 1829-1833, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819352

RESUMO

Response of personal dosemeters to high energy photon radiation is of great interest nowadays due to a spread of new radiation technologies and the expansion of occupational exposure domains. ICRU95 publication has expanded the range of relevant photon energies upwards, setting new horizons for individual monitoring. Beryllium oxide (BeO) material is increasingly popular due to its excellent optically stimulated luminescence (OSL) properties, simple readout and reasonable energy response in the low energy (below 100 keV) range. The study considers energy dependence of OSL response at higher photon energies. Energy deposition of monoenergetic photons with energy up to 15 MeV in the BeO chips of various thickness was modeled with Monte Carlo MCNP 6.2 code. Benchmark experiments were conducted at LINAC with high voltage of 6, 10 and 15 MV resulting in respective incident photon spectra. The findings of this study add knowledge regarding behavior of BeO personal dosemeters in the photon fields within the energy range above 3 MeV.


Assuntos
Luminescência , Fótons , Radioterapia de Alta Energia , Método de Monte Carlo