Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Phys Eng Express ; 10(2)2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38109783

RESUMO

This work presents an algorithm for the detection and classification of QRS complexes based on the continuous wavelet transform (CWT) with splines. This approach can evaluate the CWT at any integer scale and the analysis is not restricted to powers of two. The QRS detector comprises four stages: implementation of CWT with splines, detection of QRS complexes, searching for undetected QRS complexes, and correction of the R wave peak location in detected QRS complexes. After, the onsets and ends of the QRS complexes are detected. The algorithm was evaluated with synthetic ECG and with the manually annotated databases: MIT-BIH Arrhythmia, European ST-T, QT and PTB Diagnostic ECG. Evaluation results of the QRS detector were: MIT-BIH arrhythmia database (109,447 beats analyzed), sensitivity Se = 99.72% and positive predictivity P+ = 99.87%; European ST-T database (790522 beats analyzed), Se = 99.92% and P+ = 99.55% and QT database (86498 beats analyzed), Se = 99.97% and P+ = 99.99%. To evaluate the delineation algorithm of the QRS onset (Qi) and QRS end (J) with the QT and PTB Diagnostic ECG databases, the mean and standard deviations of the differences between the automatic and manual annotated location of these points were calculated. The standard deviations were close to the accepted tolerances for deviations determined by the CSE experts. The proposed algorithm is robust to noise, artifacts and baseline drifts, classifies QRS complexes, automatically selects the CWT scale according to the sampling frequency of the ECG record used, and adapts to changes in the heart rate, amplitude and morphology of QRS complexes.


Assuntos
Eletrocardiografia , Análise de Ondaletas , Humanos , Eletrocardiografia/métodos , Algoritmos , Arritmias Cardíacas/diagnóstico , Bases de Dados Factuais
2.
Sensors (Basel) ; 23(19)2023 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-37837133

RESUMO

A low-power long-term ambulatory ECG monitor was developed for the acquisition, storage and processing of three simultaneous leads DI, aVF and V2 with a beat-to-beat heart rate measurement in real time. It provides long-term continuous ECG recordings until 84 h. The monitor uses a QRS complex detection algorithm based on the continuous wavelet transform with splines, which automatically selects the scale for the analysis of ECG records with different sampling frequencies. It includes a lead-off detection to continuously monitor the electrode connections and a real-time system of visual and acoustic alarms to alert users of abnormal conditions in its operation. The monitor presented is based in an ADS1294 analogue front end with four channels, 24-bit analog-to-digital converters and programmable gain amplifiers, a low-power dual-core ESP32 microcontroller, a microSD memory for data storage in a range of 4 GB to 32 GB and a 1.4 in thin-film transistor liquid crystal display (LCD) variant with a resolution of 128 × 128 pixels. It has programmable sampling rates of 250, 500 and 1000 Hz; a bandwidth of 0 Hz to 50% of the selected sampling rate; a CMRR of -105 dB; an input margin of ±2.4 V; a resolution of 286 nV; and a current consumption of 50 mA for an average battery life of 84 h. The ambulatory ECG monitor was evaluated with the commercial data-acquisition system BIOPAC MP36 and its module for ECG LABEL SS2LB, simultaneously comparing the morphologies of two ECG records and obtaining a correlation of 91.78%. For the QRS detection in real time, the implemented algorithm had an error less than 5%. The developed ambulatory ECG monitor can be used for the analysis of the dynamics of the heart rate variability in long-term ECG records and for the development of one's own databases of ECG recordings of normal subjects and patients with cardiovascular and noncardiovascular diseases.


Assuntos
Eletrocardiografia Ambulatorial , Processamento de Sinais Assistido por Computador , Humanos , Frequência Cardíaca/fisiologia , Coração/fisiologia , Eletrocardiografia , Arritmias Cardíacas/diagnóstico , Algoritmos
3.
Micromachines (Basel) ; 14(9)2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37763911

RESUMO

Cardiovascular diseases are currently the leading cause of death worldwide. Thus, there is a need for non-invasive ambulatory (Holter) ECG monitors with automatic measurements of ECG intervals to evaluate electrocardiographic abnormalities of patients with cardiac diseases. This work presents the implementation of algorithms in an FPGA for beat-to-beat heart rate and RT interval measurements based on the continuous wavelet transform (CWT) with splines for a prototype of an ambulatory ECG monitor of three leads. The prototype's main elements are an analog-digital converter ADS1294, an FPGA of Xilinx XC7A35T-ICPG236C of the Artix-7 family of low consumption, immersed in a low-scale Cmod-A7 development card integration, an LCD display and a micro-SD memory of 16 Gb. A main state machine initializes and manages the simultaneous acquisition of three leads from the ADS1294 and filters the signals using a FIR filter. The algorithm based on the CWT with splines detects the QRS complex (R or S wave) and then the T-wave end using a search window. Finally, the heart rate (60/RR interval) and the RT interval (from R peak to T-wave end) are calculated for analysis of its dynamics. The micro-SD memory stores the three leads and the RR and RT intervals, and an LCD screen displays the beat-to-beat values of heart rate, RT interval and the electrode connection. The algorithm implemented on the FPGA achieved satisfactory results in detecting different morphologies of QRS complexes and T wave in real time for the analysis of heart rate and RT interval dynamics.

4.
Artigo em Inglês | MEDLINE | ID: mdl-21095640

RESUMO

A prototype of a ECG ambulatory system for long term monitoring of ST segment of 3 leads, low power, portability and data storage in solid state memory cards has been developed. The solution presented is based in a mobile embedded architecture of a portable entertainment device used as a tool for storage and processing of bioelectric signals, and a mid-range RISC microcontroller, PIC 16F877, which performs the digitalization and transmission of ECG. The ECG amplifier stage is a low power, unipolar voltage and presents minimal distortion of the phase response of high pass filter in the ST segment. We developed an algorithm that manages access to files through an implementation for FAT32, and the ECG display on the device screen. The records are stored in TXT format for further processing. After the acquisition, the system implemented works as a standard USB mass storage device.


Assuntos
Computadores de Mão , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Software , Humanos
5.
Comput Biol Med ; 36(5): 507-15, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-15899477

RESUMO

We propose novel indices of ventricular repolarization intervals, the JTp/JT, Tpe/JTp and Tpe/JT ratios. These indices have been compared with the duration of the ventricular repolarization intervals and other ratios in 17 normal subjects and 17 patients with old myocardial infarction. In the intervals and other ratios, the best separation between groups is obtained with the Tpe/QTp and Tpe/QT ratios with 94% sensitivity and 82% specificity, the proposed ratios increased sensitivity to 100% and specificity to 94%. These indices should be further tested to determine their usefulness in discriminating between OMI patients with and without susceptibility to ventricular arrhythmias.


Assuntos
Ventrículos do Coração/patologia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Processamento de Sinais Assistido por Computador , Adulto , Algoritmos , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Infarto do Miocárdio/patologia , Fatores de Risco , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...