Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Refract Surg ; 25(12): 1061-74, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20000287

RESUMO

PURPOSE: To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. METHODS: Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic LASIK, myopic photorefractive keratectomy (PRK), or hyperopic LASIK who underwent phacoemulsification without complications in 3 eye centers. All IOL calculations used the average from the central 2-mm Orbscan II total-mean power of maps centered on the pupil without the use of previous refractive data. Six IOL styles implanted within the bag were used. RESULTS: Using the SRK-T formula, the overall calculated refraction was -0.64+/-0.93 diopters (D). The overall achieved spherical equivalent refraction (-0.52+/-0.79 D; range: -3.12 to 1.25 D; 95% confidence interval [CI]: -0.70/-0.34 D) was +/-0.50 D in 53% of eyes, +/-1.00 D in 78% of eyes, and +/-2.00 D in 99% of eyes. The overall difference between the calculated and achieved refraction (0.12+/-0.93 D, P=.27; range: -2.18 to 2.62 D; 95% CI: 0.09/0.33 D) was +/-0.50 D in 39% of eyes, +/-1.00 D in 77% of eyes, and +/-2.00 D in 96% of eyes. This difference was +/-1.00 D in 77% of eyes with RK (P=.70), 82% of eyes with myopic LASIK (P=.34), and 90% of eyes with myopic PRK (P=.96). In eyes with RK followed by LASIK, a trend toward undercorrection was noted (P=.03). In eyes with hyperopic LASIK, a trend toward overcorrection was noted (P=.005). CONCLUSIONS: In eyes with previous corneal refractive surgery, IOL power calculation can be performed with reasonable accuracy using the Orbscan II central 2-mm total-mean power. This method had better outcomes in eyes with previous RK, myopic LASIK, and myopic PRK than in eyes with hyperopic LASIK or RK with LASIK.


Assuntos
Cirurgia da Córnea a Laser , Topografia da Córnea/métodos , Lentes Intraoculares , Óptica e Fotônica , Humanos , Hiperopia/cirurgia , Implante de Lente Intraocular , Miopia/cirurgia , Facoemulsificação , Estudos Prospectivos
2.
J Refract Surg ; 23(1): 89-92, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17269249

RESUMO

PURPOSE: To present a new application of quantitative area pachymetry of the cornea. METHODS: Sectorial quantitative area pachymetry of small corneal zones located at the center and surrounding areas is possible by means of the statistical analysis device and tools menu of Orbscan II (Bausch and Lomb). RESULTS: Average pachymetry of 1 central zone and 12 small zones around the center may be shown in the pachymetry map by simply formatting the system. Average pachymetry, standard deviation, rate of thickness variation (slope), and volume of analyzed annular corneal zone can also be automatically shown in a data window. The examination results can be printed and kept on record. CONCLUSIONS: The method is simple and descriptive. This type of preoperative evaluation may guide the manual or laser preparation of channels for intracorneal segments and the corneal trephination for lamellar or penetrating keratoplasty.


Assuntos
Córnea/diagnóstico por imagem , Topografia da Córnea/instrumentação , Córnea/citologia , Desenho de Equipamento , Humanos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...