BACKGROUND: The optimal contact force (CF) for ventricular mapping and ablation remains unvalidated. We assessed CF in different endocardial and epicardial regions during ventricular tachycardia substrate mapping using a CF-sensing catheter (Smartouch; Biosense-Webster) and compared the transseptal versus retroaortic approach. METHODS AND RESULTS: In total, 8979 mapping points with CF, and force vector orientation (VO) were recorded in 21 patients, comprising 13 epicardial, 12 left ventricular (6 transseptal and 6 retroaortic approach), and 12 right ventricular endocardial maps. VO was defined as adequate when the vector was directed toward the myocardium. During epicardial mapping, 46% of the points showed an adequate VO and a median CF of 8 (4-13) g, however, with significant differences among the 8 regions. When VO was inadequate, median CF was higher at 16 (10-24) g (P<0.0001). During left ventricular and right ventricular endocardial mapping, 94% of VO were adequate. Median CF of adequate VO was higher in the left ventricular and right ventricular endocardium than in the epicardium (15 [8-25] and 13 [7-22] g versus 8 [4-13] g, respectively; both P<0.001). Global median left ventricular CF with transseptal approach was not statistically different from retroaortic approach, but CF in the apicoinferior and apicoseptal regions was higher with transseptal approach (P<0.001). CONCLUSIONS: Ventricular mapping demonstrates important regional variations in CF, but in general, CF is higher endocardially than epicardially where poor catheter orientation is associated with higher CF. A transseptal approach may lead to improved contact particularly in the apicoseptal and inferior regions.


Assuntos
Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Endocárdio/fisiopatologia , Monitorização Intraoperatória/métodos , Pericárdio/fisiopatologia , Taquicardia Ventricular/diagnóstico , Potenciais de Ação , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/efeitos adversos , Valor Preditivo dos Testes , Processamento de Sinais Assistido por Computador , Estresse Mecânico , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...