1.
Front Pediatr ; 5: 276, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29312908

RESUMO

BACKGROUND: Near-infrared spectroscopy (NIRS) has been used to non-invasively measure specific tissue oxygen saturation (StO2) continuously. Cerebral autoregulation status can be derived from NIRS and arterial blood pressure. The relationship of both cerebral and somatic StO2, fractional tissue oxygen extraction (FTOE), and cerebro-splanchnic oxygenation ratio (CSOR) with measured vital sign parameters for Neonatal Intensive Care Unit (NICU) patients has not been well studied. OBJECTIVE: The aims of this study are to determine if significant relationships of brain and somatic StO2, brain and somatic FTOE, and CSOR parameters with vital signs for neonates exist and assess relationship between pressure passivity index, cerebral autoregulation, and mean blood pressure (MBP). DESIGN/METHODS: Neonates weighing < 5 kg, preferentially with an arterial catheter, were enrolled in the study. FORE-SIGHT Elite (CASMedical Systems, Inc., Branford, CT, USA) cerebral and somatic NIRS sensors were placed over the abdominal right upper quadrant and right frontal-temporal area of the forehead for 24 h. Vital signs including arterial MBP were recorded simultaneously from the patients' bedside monitor. Data were averaged into 60 s windows and analyzed using linear regression. Results were stratified by gestational age (GA), birth weight (BW), and presence of brain abnormality. RESULTS: Data were obtained from 27 subjects (GA 22.2-42 weeks). Two subjects did not have an arterial line, thus they were not included in the MBP measurements. There were ~28,000-31,000 paired data points per comparison. Significant positive and negative correlations (p value < 0.0001) were noted between NIRS parameters and vital signs. When stratified by BW, there was a positive correlation between brain StO2 (StO2B) and MBP in the <1,500 g BW group (r = 0.193) and a negative correlation in >1,500 g group (r = 0.057). Brain and somatic FTOE in <1,500 g BW revealed a negative correlation with MBP (r = 0.172 and r = 0.086, respectively). In patients with an abnormal brain scan, a positive correlation was noted between StO2B and MBP (r = 0.354), and a negative correlation was noted between FTOE-B and MBP (r = 0.305). Generated pressure passive index plots suggested good cerebral autoregulation at low normal MBP ranges for lower weight and GA subjects. CONCLUSION: There is a significant correlation between cerebral and somatic StO2 and FTOE with measured vital sign parameters in NICU patients.

2.
J Pediatr Nurs ; 29(2): 143-51, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24707548

RESUMO

Patient safety and error reduction are essential to improve patient care, and new technology is expected to contribute to such improvements while reducing costs and increasing care efficiency in health care organizations. The purpose of this study was to assess the relationships among pediatric nurses' perceptions of smart infusion pump (SIP) technology, patient safety, and error reduction. Findings revealed that RNs' perceptions of SIP correlated with patient safety. No significant relationship was found between RNs' perceptions of SIP and error reduction, but data retrieved from the pumps revealed 93 manipulations of the pumps, of which error reduction was captured 65 times.


Assuntos
Atitude do Pessoal de Saúde , Bombas de Infusão/tendências , Infusões Intravenosas/instrumentação , Erros de Medicação/prevenção & controle , Recursos Humanos de Enfermagem Hospitalar/psicologia , Enfermagem Pediátrica , Humanos , Bombas de Infusão/normas , Segurança do Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...