Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Eur J Cardiothorac Surg ; 52(6): 1069-1076, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28481994

RESUMO

OBJECTIVES: Right heart failure (RHF) after the implantation of a left ventricular assist device (LVAD) remains a dreaded postoperative complication. Using 2D speckle-tracking echocardiography, it is possible to acquire right ventricular global and regional function. The aim of our study was to assess whether speckle-tracking echocardiography values will better predict the RHF post-continuous-flow LVAD implantation. METHODS: From January 2014 to January 2016, 54 patients who underwent LVAD implantation were included and retrospectively analysed. Clinical, invasive haemodynamic (right and left heart catheterization), laboratory and transthoracic echocardiography data were reviewed. Multivariable logistic regression was performed using RHF as dependent variable. RESULTS: Thirteen patients (24%) developed RHF. These patients had significantly elevated procalcitonin (P = 0.011), elevated central venous pressure (CVP) pre- and post-LVAD implantation (P = 0.002 and 0.031, respectively), higher right ventricular (RV) and pulmonary systolic pressure (P = 0.016 and 0.013, respectively), higher Michigan Risk Score (P = 0.001) and a lower peak systolic longitudinal strain of the basal RV free wall (P = 0.032). Haemoglobin, procalcitonin, RV systolic pressure, basal right ventricular free wall and pre-CVP entered the final multivariable analysis, only basal right ventricular free wall (P < 0.001) and pre-CVP (P < 0.001) remained significant predictors of RHF. The sensitivity and specificity of the final model were 85.7% and 95.4%, respectively. The negative predictive value reached 94%. CONCLUSIONS: 2D strain parameters of the RV free wall seem to be auspicious for RV function and predicting RHF. Moreover, intraoperative CVP should not be neglected since elevated values proved to be highly associated with RHF. Our results represent a valuable supplement to other scores by considering both echocardiography and intraoperative data.


Assuntos
Ecocardiografia/métodos , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Função Ventricular Direita/fisiologia , Progressão da Doença , Feminino , Seguimentos , Alemanha/epidemiologia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/etiologia , Ventrículos do Coração/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
2.
Artif Organs ; 39(10): 903-15, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26378868

RESUMO

The development of a transcatheter tricuspid valve prosthesis for the treatment of tricuspid regurgitation (TR) is presented. The design process involves an iterative development method based on computed tomography data and different steps of finite element analysis (FEA). The enhanced design consists of two self-expandable stents, one is placed inside the superior vena cava (SVC) for primary device anchoring, the second lies inside the tricuspid valve annulus (TVA). Both stents are connected by flexible connecting struts (CS) to anchor the TVA-stent in the orthotopic position. The iterative development method includes the expansion and crimping of the stents and CS with FEA. Leaflet performance and leaflet-stent interaction were studied by applying the physiologic pressure cycle of the right heart onto the leaflet surfaces. A previously implemented nitinol material model and a new porcine pericardium material model derived from uniaxial tensile tests were used. Maximum strains/stresses were approx. 6.8% for the nitinol parts and 2.9 MPa for the leaflets. Stent displacement because of leaflet movement was ≤1.8 mm at the commissures and the coaptation height was 1.6-3 mm. This led to an overall good performance of the prosthesis. An anatomic study showed a good anatomic fit of the device inside the human right heart.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Valva Tricúspide , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese/métodos , Stents , Tomografia Computadorizada por Raios X , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Veia Cava Superior/cirurgia
3.
Interact Cardiovasc Thorac Surg ; 19(3): 414-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24916580

RESUMO

OBJECTIVES: Interventional treatment of tricuspid valve disease has so far received little attention due to the anatomical challenges in a thrombogenic surrounding. In the present study, we present an imaging-based, personalized interventional approach to the therapy of tricuspid regurgitation. METHODS: In our porcine model, we used rapid prototyping to build a matrix reproducing the geometry of the right atrium that was previously derived from computer tomography (CT) scans. Over this matrix, a braided nitinol device fitting almost completely the right atrium was crafted. An additional tubular stent component was developed to carry a tissue valve prosthesis. This part was designed to be connectable to the annular portion of the main device. In our feasibility study, the crimped device was implanted via jugular access into the right atrium of 12 pigs and expanded subsequently. Following isolated implantation of the device without the valve-carrying component, further procedures included implantation of the whole composite device, including the mentioned tissue valve. Representing a only feasibility study, all implantations were performed under full bypass and direct sight. On-site visualization was performed by both echocardiography and fluoroscopy. Additional imaging was realized by postoperative CT scans. RESULTS: Following implantation, 9 of 12 animals were weaned from cardiopulmonary bypass. Correct positioning of the device and orthodromic blood flow as maintained by the valve prosthesis were demonstrated by echocardiography and fluoroscopy. Postoperative contrast CT evaluation demonstrated proper fitting of the device into the right-sided heart cavities without obstruction of the outflow tract. Autopsy additionally confirmed its correct positioning without major trauma to surrounding structures. CONCLUSIONS: We demonstrated the feasibility in principle of a personalized interventional treatment for tricuspid regurgitation using a braided stent, based on individual cardiac imaging, with anchoring forces mainly exerted on the venae cavae and on the inner surface of the right atrium. The design process of this device is a good indicator of the growing potential of an imaging-based personalized simulation and production approach for the treatment of tricuspid valve disease.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/terapia , Ligas , Animais , Cateterismo Cardíaco/instrumentação , Desenho Assistido por Computador , Estudos de Viabilidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Teste de Materiais , Modelos Animais , Medicina de Precisão , Desenho de Prótese , Stents , Suínos , Tomografia Computadorizada por Raios X , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/fisiopatologia , Ultrassonografia
4.
Interact Cardiovasc Thorac Surg ; 17(1): 44-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23543405

RESUMO

OBJECTIVES: Right ventricular failure is often the final phase in acute and chronic respiratory failure. We combined right ventricular unloading with extracorporeal oxygenation in a new atrio-atrial extracorporeal membrane oxygenation (ECMO). METHODS: Eleven sheep (65 kg) were cannulated by a 28-Fr inflow cannula to the right atrium and a 25-Fr outflow cannula through the lateral left atrial wall. Both were connected by a serial combination of a microaxial pump (Impella Elect(®), Abiomed Europe, Aachen, Germany) and a membrane oxygenator (Novalung(®)-iLA membrane oxygenator; Novalung GmbH, Hechingen, Germany). In four animals, three subsequent states were evaluated: normal circulation, apneic hypoxia and increased right atrial after load by pulmonary banding. We focused on haemodynamic stability and gas exchange. RESULTS: All animals reached the end of the study protocol. In the apnoea phase, the decrease in PaO2 (21.4 ± 3.6 mmHg) immediately recovered (179.1 ± 134.8 mmHg) on-device in continuous apnoea. Right heart failure by excessive after load decreased mean arterial pressure (59 ± 29 mmHg) and increased central venous pressure and systolic right ventricular pressure; PaO2 and SvO2 decreased significantly. On assist, mean arterial pressure (103 ± 29 mmHg), central venous pressure and right ventricular pressure normalized. The SvO2 increased to 89 ± 3% and PaO2 stabilized (129 ± 21 mmHg). CONCLUSIONS: We demonstrated the efficacy of a miniaturized atrio-atrial ECMO. Right ventricular unloading was achieved, and gas exchange was well taken over by the Novalung. This allows an effective short- to mid-term treatment of cardiopulmonary failure, successfully combining right ventricular and respiratory bridging. The parallel bypass of the right ventricle and lung circulation permits full unloading of both systems as well as gradual weaning. Further pathologies (e.g. ischaemic right heart failure and acute lung injury) will have to be evaluated.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/terapia , Coração Auxiliar , Insuficiência Respiratória/terapia , Disfunção Ventricular Direita/terapia , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Oxigenação por Membrana Extracorpórea/instrumentação , Estudos de Viabilidade , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Miniaturização , Oxigênio/sangue , Troca Gasosa Pulmonar , Insuficiência Respiratória/sangue , Insuficiência Respiratória/fisiopatologia , Ovinos , Fatores de Tempo , Disfunção Ventricular Direita/sangue , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita
5.
Front Biosci (Elite Ed) ; 5(2): 546-50, 2013 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-23277010

RESUMO

Currently, there are no fully developed interventional approaches for the treatment of tricuspid regurgitation (TR). The aim of this study was to evaluate the feasibility of orthotopic interventional placement of a biological prosthetic valve in the tricuspid position by inserting, with a transvenous approach, a self-expandable valve-bearing stent into the right atrium. Based on findings of computerized tomography (CT), a model of the porcine right heart was obtained. A self-expanding vascular endoprosthesis, carrying a prosthetic heart valve, was reshaped to fit the superior vena cava and the tricuspid annulus. Fenestrations were created to allow blood flow from the inferior vena cava and coronary sinus. This new device ("tricuspid endoprosthesis": TE) was implanted operatively into the superior vena cava, right atrium, and tricuspid annulus in six pigs. CT demonstrated proper fitting of the device, and echocardiography demonstrated correct positioning and function of the TE. Five animals were successfully weaned from cardiopulmonary bypass. Autopsy confirmed correct positioning of the TE without major trauma to surrounding tissues. These findings demonstrate a complete interventional approach for treating TR.


Assuntos
Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Insuficiência da Valva Tricúspide/cirurgia , Animais , Ecocardiografia , Átrios do Coração/cirurgia , Hemodinâmica , Suínos , Tomografia Computadorizada por Raios X
6.
J Cardiothorac Surg ; 7: 85, 2012 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-22958313

RESUMO

BACKGROUND: The main objective of this study will be to determine the effects of a new advanced sternum external fixation (Stern-E-Fix) corset on prevention of sternal instability and mediastinitis in high-risk patients. METHODS: This prospective, randomized study (January 2009 - June 2011) comprised 750 male patients undergoing standard median sternotomy for cardiac procedures (78% CABG). Patients were divided in two randomized groups (A, n = 380: received a Stern-E-Fix corset postoperatively for 6 weeks and B, n = 370: control group received a standard elastic thorax bandage). In both groups, risk factors for sternal dehiscence and preoperative preparations were similar. RESULTS: Wound infections occurred in n = 13 (3.42%) pts. in group A vs. n = 35 (9.46%) in group B. In group A, only 1 patient presented with sternal dehiscence vs. 22 pts. in group B. In all 22 patients, sternal rewiring followed by antibiotic therapy was needed. Mediastinitis related mortality was none in A versus two in B. Treatment failure in group B was more than five times higher than in A (p = 0.01); the mean length of stay in hospital was 12.5 ± 7.4 days (A) versus 18 ± 15.1 days (B) (p=0.002). Re-operation for sternal infection was 4 times higher in group B. Mean ventilation time was relatively longer in B (2.5 vs. 1.28 days) (p = 0.01). The mean follow-up period was 8 weeks (range 6 - 12 weeks). CONCLUSIONS: We demonstrated that using an external supportive sternal corset (Stern-E-Fix) yields a significantly better and effective prevention against development of sternal dehiscence and secondary sternal infection in high-risk poststernotomy patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Esterno/cirurgia , Deiscência da Ferida Operatória/prevenção & controle , Técnicas de Fechamento de Ferimentos/instrumentação , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Fixadores Externos , Humanos , Tempo de Internação , Masculino , Mediastinite/epidemiologia , Mediastinite/prevenção & controle , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Fatores de Risco , Deiscência da Ferida Operatória/epidemiologia , Técnicas de Fechamento de Ferimentos/estatística & dados numéricos
7.
ASAIO J ; 58(6): 568-73, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22990286

RESUMO

Tricuspid valve regurgitation mostly occurs as result of dilation of the right ventricle, secondary to left heart valve diseases. Until recently, little attention has been given to the development of percutaneous therapeutic tools exclusively designed for tricuspid valve disease. A new approach to the interventional therapy of tricuspid regurgitation, in particular, the design of a conceptual new valve-bearing, self-expansible stent, is presented here. A three-dimensional computer model of a right porcine heart was developed to gain a realistic anatomical geometry. The new design consists of two tubular stent elements, one inside the superior vena cava and the other inside the tricuspid valve annulus after being eventually equipped with a biological valve prosthesis, which are connected by struts. Anchoring to the heart structure is provided primarily by the vena cava stent, strengthened by the struts. The stents are designed to be cut from a 10 mm tube and later expanded to their designated diameter. Simulation software analyzing the expansion process with respect to the intended geometrical design is used in an iterative process. A validation of the anatomical geometry and function of the stent design inside a silicone model within in vitro tests and a random porcine heart shows an accurate anatomical fitting.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Stents , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Animais , Desenho de Prótese , Suínos
8.
J Cardiothorac Surg ; 7: 15, 2012 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-22309934

RESUMO

BACKGROUND: Right ventricular failure (RVF) and -support is associated with poor results. We aimed for a new approach of right - sided assistance bypassing the right ventricle and pulmonary circulation in order to better decompress the right ventricle and optimize left ventricular filling. METHODS: From a microaxial pump (Abiomed), a low resistance oxygenator (Maquet and Novalung) and two cannulas (28 and 27 Fr) a system was set up and evaluated in an ovine model (n = 7). Connection with the heart was the right and left atrium. One hour the system was operated without RVF and turned of again. Then a RVF was induced and the course with the system running was evaluated. Complete hemodynamic monitoring was performed as well as echocardiography, flow measurement and blood gas analysis. RESULTS: The overall performance of the system was reliable. Without RVF no relevant changes of hemodynamics occurred; blood gases were supra normal. In RVF a cardiogenic shock developed (MAP 35 ± 13 mmHg, CO 1,1 ± 0,7 l/min). Immediately after starting the system the circulation normalized (significant increase of MAP to 85 ± 13 mmHg, of CO to 4,5 ± 1,9). Echocardiography also revealed right ventricular recovery. After stopping the system, RVF returned. CONCLUSIONS: Bypassing the right ventricle and pulmonary circulation with an oxygenating assist device, which may offer the advantages of enhanced right ventricular decompression and augmented left atrial filling, is feasible and effective in the treatment of acute RVF. Long time experiments are needed.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Animais , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração , Circulação Pulmonar , Ovinos
9.
Interact Cardiovasc Thorac Surg ; 14(1): 108-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22108927

RESUMO

We present a seldom seen case of Takotsubo cardiomyopathy (TCM) with concurrent obstructive coronary artery disease (OCAD) and its first case surgical experience. We propose that TCM and OCAD can coexist and that the presence of OCAD should not be an exclusion criterion for the diagnosis of TCM.


Assuntos
Ponte de Artéria Coronária/métodos , Estenose Coronária/cirurgia , Cardiomiopatia de Takotsubo/cirurgia , Idoso , Angiografia Coronária , Estenose Coronária/complicações , Estenose Coronária/diagnóstico , Diagnóstico Diferencial , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/diagnóstico
10.
Front Biosci (Landmark Ed) ; 16(6): 2342-51, 2011 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-21622180

RESUMO

In right ventricular failure (RVF) a decrease of right ventricular afterload and improvement of left atrial filling could be achieved by a pulmonary artery-left atrial (PA)-shunt. To avoid cyanosis, artificial oxygenation is necessary. In 11 pigs a PA-shunt was created. An interventional lung assist device (ILA) was installed from the femoral artery to vein in 5 pigs (serial in relation to native lung: Group I) and into the PA-shunt in 6 pigs (parallel: Group II). RVF was induced by pulmonary artery banding. Right ventricular performance was determined by pulse contour analysis, pressure - and flow measurements. In both groups a stable RVF was generated. In Group I cardiac output trended to increase but neither right ventricular filling pressures nor arterial pressure changed significantly. The PaO2 decreased significantly. In Group II cardiac output and arterial pressure increased significantly under a shunt flow of 2.3- 2.6 l/min and the animals recovered from cardiogenic shock. In conclusion a PA-shunt with a parallel lung assist can effectively reverse the deleterious effects of RVF.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Disfunção Ventricular Direita/cirurgia , Animais , Órgãos Artificiais , Pressão Sanguínea , Débito Cardíaco , Modelos Animais de Doenças , Feminino , Átrios do Coração/cirurgia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Pulmão/cirurgia , Artéria Pulmonar/cirurgia , Troca Gasosa Pulmonar , Sus scrofa , Disfunção Ventricular Direita/fisiopatologia
11.
Eur J Cardiothorac Surg ; 39(3): 335-41, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20675149

RESUMO

OBJECTIVE: Current alternative approaches for pacemaker lead implantation imply the breach of the pleural space. Recently, the feasibility of experimental lead implantation by rigid endoscopy has been described. The use of flexible endoscopes and a standardised application has not been realised yet. Our main goal was to compare rigid and flexible endoscopy and to establish a standardised protocol for the implementation of a closed-chest subxiphoid approach for epimyocardial lead implantation. METHODS: Rigid and flexible endoscopes were used for placement of screw-in pacing leads (4-F). A total of 17 adult pigs (80 kg) were anaesthetised and a 10-mm subxiphoid axial incision performed. The pericardium was opened and entered under endoscopic vision. Epimyocardial electrodes were implanted through the endoscope onto all four chambers. Standard haemodynamic measurements and pacing measurements were carried out. RESULTS: Both methods were deployed in the first three individuals. Superior endorsement of rigid endoscopy, due to better orientation and stability, led to its exclusive deployment in the remaining 14 individuals. Access to the implantation sites was quick (<10 min). A plastic cover had to be applied to reduce arrhythmia (VentricularExtraSystoles(bare): 17 ± 2.2 min(-1) vs VentricularExtraSystoles(cover): 5 ± 1.9 min(-1); n = 4). Measured pacing parameters were comparable with classic endocardial-derived thresholds. Post-mortem examination revealed no relevant damage/injury and/or bleeding in the heart and circumjacent tissue. There was no evidence of injury at the implantation sites and the corresponding pericardium. The electrodes showed excellent anchorage inside the myocardial tissue (penetration depths: 3 ± 0.2mm) and resisted high tractive forces. CONCLUSION: Flexible endoscopy is not suitable for exclusive deployment inside the pericardial space, whereas rigid endoscopy presented itself as a safe, fast and simple approach for epimyocardial lead implantation using an insulating trocar. Without cover, malignant arrhythmia constrains the implementation of video-assisted pericardioscopic surgery (VAPS). Subxiphoid VAPS permits optimal lead positioning under direct vision without fluoroscopy, without the breach of the pleural space and with a short procedural duration (<60 min). Our standardised minimal-invasive approach allows visualisation and intervention, potentially of all intrapericardial structures.


Assuntos
Marca-Passo Artificial , Pericardiectomia/métodos , Cirurgia Vídeoassistida/métodos , Animais , Estimulação Cardíaca Artificial , Eletrodos Implantados , Estudos de Viabilidade , Feminino , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Pericardiectomia/efeitos adversos , Pericardiectomia/instrumentação , Sus scrofa , Aderências Teciduais/etiologia , Cirurgia Vídeoassistida/efeitos adversos , Cirurgia Vídeoassistida/instrumentação
12.
Front Biosci (Elite Ed) ; 2(4): 1368-73, 2010 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-20515809

RESUMO

An apico-aortic conduit (AAC) is an alternative therapy in patients with aortic valve stenosis and severe concomitant disease. We investigated whether it is feasible to create an apico-aortic conduit off-pump with a newly developed, stent-based coring- and cannulation-device in the animal model. A new self-expandable, stent equipped and hooked prosthesis and a sheath enabling both airtight removal of tissue and introduction of the prosthesis were designed and experimentally investigated in six pigs. Hemodynamic- and echocardiographic investigations were performed without and with aortic stenosis. In three animals MRI was performed. There was no significant blood loss, no relevant contamination with air and no hemodynamic depression during the whole procedure. It was possible to yield the entire cardiac output through the conduit after creating a high grade aortic stenosis. Autopsy revealed an excellent anchorage of the prosthesis. Neither relevant intracavitary injury nor thrombotic formation was seen. This study proves the feasibility of a stent-based, off-pump creation of an AAC. The principle of this approach might be used for other purposes.


Assuntos
Aorta , Próteses Valvulares Cardíacas , Stents , Animais , Feminino , Imageamento por Ressonância Magnética , Suínos
13.
Eur J Cardiothorac Surg ; 28(6): 845-9, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16275000

RESUMO

OBJECTIVE: We sought to determine, by a mathematical model, the ideal theoretical degree of ascending aortic graft oversizing needed to obtain normal sinuses dimension in the reimplantation type of valve-sparing aortic operations. METHODS: To define a normal-range value, size of sinuses of Valsalva was conventionally expressed as the area surrounding fully opened aortic cusps, the so-called beyond leaflets area (BLA), and measured in 50 healthy subjects. A mathematical relationship between aortic annulus diameter, aortic sinuses diameter and resulting BLA was defined. By simulating intra-operative scenarios, the effect of different degrees of a standard or Valsalva graft oversizing on BLA extension was tested. RESULTS: The same degree of graft oversizing resulted in a bigger beyond leaflets area for the Valsalva graft than for a standard graft. Oversizing degrees exceeding +7mm for a standard graft and +3mm for the Valsalva graft resulted in a beyond leaflets area over normal limits. Results were expressed in a visual form as two different normograms, one for the standard graft and one for the Valsalva graft. CONCLUSIONS: A less pronounced graft oversizing is needed to achieve normal-range sinuses size when using a Valsalva graft, the ideal theoretical graft oversizing was +7mm for a standard graft and +3mm for the Valsalva graft, our normograms can be helpful in selecting a proper graft size when performing a valve-sparing aortic procedure.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Prótese Vascular , Modelos Cardiovasculares , Seio Aórtico/cirurgia , Adulto , Implante de Prótese Vascular/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Valores de Referência , Reimplante/métodos , Seio Aórtico/anatomia & histologia , Seio Aórtico/diagnóstico por imagem , Ultrassonografia
14.
Ital Heart J ; 5(4): 299-301, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15185890

RESUMO

Cardiac hemangiomas are exceptionally rare tumors with an incidence of 1 to 3% of all detected benign heart neoplasms. We report 2 cases of left atrial hemangioma of which only one associated with clinical symptoms such as dyspnea and palpitations. Two years following surgical excision of the tumors, there was no echocardiographic evidence of recurrence.


Assuntos
Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/patologia , Hemangioma/diagnóstico por imagem , Hemangioma/patologia , Idoso , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Neoplasias Cardíacas/cirurgia , Hemangioma/cirurgia , Humanos , Masculino , Ultrassonografia
15.
Ital Heart J ; 5(3): 197-204, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15119502

RESUMO

BACKGROUND: A retrospective study on octogenarians who underwent off-pump (OPCAB) or conventional (CCAB) coronary artery bypass surgery undertaken to evaluate the in-hospital and early outcomes in terms of survival and cardiac and neurological events. METHODS: The design of the study was single-institutional, retrospective and comparative. Between January 1997 and May 2003, 114 patients were included and 73 underwent OPCAB, while 41 underwent CCAB. Uni- and multivariate analyses were used to determine the correlation between the pre- and intraoperative data and hospital death or complications. The overall survival and freedom from cardiac events were determined using Kaplan-Meier analysis. The linearized rates of follow-up complications were compared between the two groups. RESULTS: Overall, comparison of CCAB to OPCAB revealed differences in the operative mortality (6 deaths for CCAB, 14.6% vs 5 deaths for OPCAB, 6.8%; p = 0.05). Postoperative complication variables showed that there was no significant difference in the number of patients who suffered from cardiac events and stroke (2.4% CCAB vs 1.4% OPCAB, p = NS) whereas there was a significant difference for minor neurological events (12.2% CCAB vs 2.8% OPCAB, p = 0.04). The mean follow-up was 2.1 +/- 1.8 years, for a total follow-up of 234 patient-years. There were 12 late deaths, 6 in the CCAB group and 6 in the OPCAB group. The linearized rate of overall death was 9.5 +/- 2.6%/year in the CCAB group and 13.3 +/- 3.9%/year in the OPCAB group (p = NS). The actuarial survival at 24 months was 84 +/- 7% for OPCAB and 81 +/- 12% for CCAB (p = NS). The actuarial freedom from cardiac events at 24 months was 89 +/- 4% for OPCAB and 90 +/- 6% for CCAB (p = NS). The linearized rate of neurological events was 0.7 +/- 0.7%/year for the CCAB group and 1.1 +/- 1.1%/year for the OPCAB group (p = NS). CONCLUSIONS: Our analysis shows that OPCAB improves the early outcome and that octogenarians can lead event-free lives after cardiac surgery.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Idoso , Idoso de 80 Anos ou mais , Doença das Coronárias/mortalidade , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Tempo de Internação , Masculino , Análise Multivariada , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico/fisiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...