Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
West Afr J Med ; 40(12 Suppl 1): S38-S39, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38071469

RESUMO

Introduction: A screening tool for obstructive sleep apnoea (OSA) is useful in low-income countries where it may be difficult to access sleep recordings. The objective of this study was to assess the performance of six screening scores compared with objective sleep recording in an African population sample. Methods: This analysis is based on the "Benin Sleep and Society" (BeSAS) populational study in which respiratory polygraphy (PG) was performed using a type III device and OSA screening questionnaires (STOP, STOP-Bang, Berlin, NOSAS [≥ 8 and ≥ 5), No-Apnea, GOAL) were administered to participants. PG-defined OSA severity categories were defined according to the apnoea-hypopnoea index (AHI): mild (AHI 5 to <15/h), moderate (AHI 15 to <30/h) or severe (AHI≥30/h), and these were compared to score findings. Results: A total of 1810 subjects (mean age 45.4±14.6 years; 57.3% women) were included. For moderate to severe OSA, the area under the receiving operating characteristic (ROC) curve was greatest for GOAL and No-Apnea (0.70), followed by NoSAS5 (0.69). The highest sensitivity values were for NoSAS5 (0.73), No-Apnea (0.72), and GOAL (0.69), while NoSAS8 had the highest specificity (0.91), followed by Berlin (0.88) and GOAL (0.71). All scores performed poorly with respect to the positive predictive value (PPV), which was highest with NoSAS8 (0.38). Conclusion: This study provides the first comparison of the performance of screening scores for OSA in an African population. Although still low, PPV was highest with NoSAS8. Hence, NoSAS8 would be the screening method of choice for OSA in resource-constrained settings where formal sleep recordings are not accessible.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Inquéritos e Questionários , Apneia Obstrutiva do Sono/diagnóstico , Programas de Rastreamento/métodos , Valor Preditivo dos Testes , Polissonografia
2.
West Afr J Med ; 40(12 Suppl 1): S39-S40, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38071478

RESUMO

Background: The Epworth Sleepiness Scale (ESS) is a tool widely used to assess excessive daytime sleepiness. Unfortunately, it is not reliable in low-income countries where situations such as reading a book, watching TV or driving a car are not common. The aim of this study was thus to assess the performance of a modified version of the Epworth scale in a low-income country. Methods: We used data from the Benin Society and Sleep (BeSAS) study where the ESS and a modified ESS (mESS) were administered to participants. In the mESS, questions four questions over eight were redesigned to reflect common living situations in Benin. The internal coherence of the mESS was assessed using the Cronbach alpha coefficient (CAC). The discriminatory ability of the scale was assessed by comparing the mean scores according to reported sleep quality, insomnia complaints and apnea-hypopnea index (AHI). Results: A total of 2909 participants were recruited, 1129 were male (38.9%) with a mean age (SD) of 44.7 (14.5) y. Overall, 52.4% (1526) completed all the mESS questions while 453 (15.6%) completed the standard ESS. The CAC of the mES was 0.86 showing good internal coherence. Concerning the discriminatory ability, mean scores for mESS were 7.8 for participants with ISI < 8 vs 9.2 for participants with ISI≥8 (p<0.001), 7.8 for participants withPSQI<5 vs 8.3 for participants with PSQI≥5 (p=0.03). No difference was found when comparing the participants participants using different cut-offs of AHI (15 and 30). Conclusion: The mES is more reliable than ES in the Beninese population. mESS shows good internal coherence and differentiates between insomniacs vs non-insomniacs and between good and poor sleepers. Although the mES is not a perfect score, it appears more relevant in the Benin population than the original Epworth scale but needs further validation/improvement in other low-income countries.


Assuntos
Distúrbios do Sono por Sonolência Excessiva , Sonolência , Humanos , Masculino , Feminino , Benin , Inquéritos e Questionários , Sono , Distúrbios do Sono por Sonolência Excessiva/diagnóstico
3.
Ann Cardiol Angeiol (Paris) ; 70(4): 183-190, 2021 Oct.
Artigo em Francês | MEDLINE | ID: mdl-34517975

RESUMO

OBJECTIVE: To describe the social representations associated with cardiovascular diseases (CVD) in the village of Tanvè in Benin. METHODS: Focus groups discussions and semi-structured interviews were conducted among participants of Tanvè Health Study (TAHES) cohort. Audio recordings were made during the interviews, as well as some note-taking. Data were organized by themes and analyzed to identify key representations that underlie attitudes and health care practices. RESULTS: A total of 19 subjects (including 11 women) participated in 2 focus groups and 17 (including 5 women) in individual interviews. Etymologies of CVD's names evoke either clinical signs (example: ''tesisi glô mɛ'' [can't stand up]), guessed etiology (example: ''kuvitɔ zɔn'' [ghosts' disease]) or a local adaptation of a biomedical name (example: ''a'tension'' [from hypertension]), to cite the example of stroke. According to beliefs about etiology, diseases were classed as ''simple'' or "organic" diseases ("azɔn yaya") and ''supernatural'' or ''induced'' diseases linked to "azé" [immaterial witchcraft] or "bô" [material bewitchment]. Chronic or recurrent diseases usually end up in the ''supranatural'' category and induce the consultation of "bokɔnɔ᷉" (diviner) or other religious for diagnosis. Health care seeking refer to modern medicine, "amanɔn" (leaf-based care), "bokɔnɔ᷉" or traditional religious (various rites) and Christians (prayers). CONCLUSION: Social representations of CVD in this community are based on ancestral beliefs, but are also influenced by modern knowledge. Taking them into account could improve quality of health to fulfill communities' care needs.


Assuntos
Doenças Cardiovasculares , Hipertensão , Benin/epidemiologia , Doenças Cardiovasculares/epidemiologia , Estudos de Coortes , Feminino , Humanos
4.
PLoS One ; 12(4): e0176512, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28441420

RESUMO

Blood Oxygenation Level Dependent functional MRI (BOLD fMRI) during electrical paw stimulation has been widely used in studies aimed at the understanding of the somatosensory network in rats. However, despite the well-established anatomical connections between cortical and subcortical structures of the sensorimotor system, most of these functional studies have been concentrated on the cortical effects of sensory electrical stimulation. BOLD fMRI study of the integration of a sensorimotor input across the sensorimotor network requires an appropriate methodology to elicit functional activation in cortical and subcortical areas owing to the regional differences in both neuronal and vascular architectures between these brain regions. Here, using a combination of low level anesthesia, long pulse duration of the electrical stimulation along with improved spatial and temporal signal to noise ratios, we provide a functional description of the main cortical and subcortical structures of the sensorimotor rat brain. With this calibrated fMRI protocol, unilateral non-noxious sensorimotor electrical hindpaw stimulation resulted in robust positive activations in the contralateral sensorimotor cortex and bilaterally in the sensorimotor thalamus nuclei, whereas negative activations were observed bilaterally in the dorsolateral caudate-putamen. These results demonstrate that, once the experimental setup allowing necessary spatial and temporal signal to noise ratios is reached, hemodynamic changes related to neuronal activity, as preserved by the combination of a soft anesthesia with a soft muscle relaxation, can be measured within the sensorimotor network. Moreover, the observed responses suggest that increasing pulse duration of the electrical stimulus adds a proprioceptive component to the sensory input that activates sensorimotor network in the brain, and that these activation patterns are similar to those induced by digits paw's movements. These findings may find application in fMRI studies of sensorimotor disorders within cortico-basal network in rodents.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/métodos , Animais , Encéfalo/irrigação sanguínea , Estimulação Elétrica , Masculino , Ratos , Ratos Wistar
5.
J Invest Surg ; 20(2): 121-33, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17454397

RESUMO

Magnetic resonance imaging (MRI) and magnetic resonance (MR) relaxometry were used to assess noninvasively the tissue response of a new uncoated hybrid braided suture made from a combination of ultra-high-molecular-weight polyethylene (UHMWPE) and polyester (polyethylene terephthalate) (PET) yarns in comparison to a silicone impregnated braided 100% polyester (PET) control suture (Ticron). Both biomaterials were monitored for a period of 30 days following implantation in both incised and nonincised paravertebral rabbit muscles. In all cases, MR images and relaxometry demonstrated that the hybrid suture elicited either a milder or a similar tissue and cellular response compared to the control suture. These findings were confirmed by conventional histological analysis of the surrounding tissues. They also demonstrated that the hybrid suture promoted faster healing in terms of collagen infiltration between the yarns and individual filaments. This milder inflammatory reaction and improved biocompatibility represent a real advantage in the healing performance of sutures for cardiac and vascular surgery, and support the need for continued research and development of hybrid structures. This study also demonstrated the ability of MRI techniques to noninvasively evaluate the biocompatibility of biomaterials. By extending the capacity of MR diagnostic tools from patients to experimental animals, it is now possible to validate the healing performance of foreign materials with statistical reliability and fewer animals.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Teste de Materiais/métodos , Suturas/efeitos adversos , Animais , Lubrificantes , Imageamento por Ressonância Magnética , Músculo Esquelético , Coelhos , Âncoras de Sutura , Resultado do Tratamento , Cicatrização
6.
IEEE Trans Med Imaging ; 23(1): 122-9, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14719693

RESUMO

This paper presents a newly developed method to estimate, in magnetic resonance (MR) images, the temperatures reached within the volume of an iceball produced by a cryogenic probe. Building on the direct measurements of the MR signal intensity and its correlation with independent temperature variations at the phase transition from liquid to solid, the thermal information embedded in the images was accessed. The volume and diameter of the growing iceball were estimated from a time series of MR images. Using regressions over the volume in the time and thermal domains, this method predicted the cryogenic temperatures beyond the range of sensitivity of the MR signal itself. We present a validation of this method in samples of gelatin and ex vivo pig liver. Temperature predictions are shown to agree with independent thermosensor readings over a range extending from 20 degrees C down to -65 degrees C, with an average error of less than 6 degrees C.


Assuntos
Algoritmos , Temperatura Corporal , Criocirurgia/métodos , Gelo , Fígado/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Termografia/métodos , Animais , Interpretação de Imagem Assistida por Computador/métodos , Técnicas In Vitro , Fígado/cirurgia , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Termografia/instrumentação
7.
Magn Reson Imaging ; 21(6): 609-15, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12915191

RESUMO

The present study was undertaken to measure the gain observed in the liver-to-tumor contrast of perioperative images when using mangafodipir trisodium, a liver-specific contrast agent, during percutaneous cryosurgery of the liver performed under the guidance of magnetic resonance images. Retrospective quantitative analyses of MR images were performed on eleven patients having a total of 30 liver tumors treated by MR-guided percutaneous cryosurgery. An initial group of four patients were treated with no contrast agent, and was compared with a second group of 7 patients who received an intravenous injection of 5 microM/kg of mangafodipir for their cryosurgery. The percutaneous cryosurgery was monitored under the near-real-time-imaging mode of a 0.5T open-configuration MRI system using a T(1)-weighted Gradient-recalled echo pulse sequence. A significant improvement in the liver-to-tumor contrast-to-noise ratio was observed with mangafodipir (p < 0.05, paired t test) in 0.5T preoperative images. Along with the stability of the mangafodipir contrast enhancement during the entire cryosurgical procedure, the resulting gain in contrast allowed for better visualizing the presence of residual untreated tumor margins at the periphery of the cryosurgery iceball directly from perioperative images acquired with patients under narcosis. Consequently, it not only became easier for the interventionalist to determine the need for an additional cryoprobe to increase the size of the iceball during the procedure, but also to decide on the appropriate end point of the cryosurgery.


Assuntos
Meios de Contraste , Criocirurgia , Ácido Edético/análogos & derivados , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Fosfato de Piridoxal/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Manganês , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...