Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Cureus ; 13(6): e15964, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34336457

RESUMO

Afferent loop syndrome is an uncommon postoperative complication. Currently, we lack a therapeutic option for treatment of malignant afferent loop obstruction following procedures like Whipple's. Here we present a case of afferent loop obstruction in a known case of pancreatic carcinoma, status after Whipple's procedure, in which we used a percutaneous transhepatic approach to relieve the afferent loop obstruction using a self-expanding bare metal stent.

3.
Catheter Cardiovasc Interv ; 96(6): 1258-1265, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32840956

RESUMO

The society for cardiovascular angiography and interventions (SCAI) think tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community for high-level field-wide discussions. The 2020 think tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease (CHD). Each session was moderated by a senior content expert and co-moderated by a member of SCAI's emerging leader mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialogue from a broader base, and thereby aid SCAI and the industry community in developing specific action items to move these areas forward.


Assuntos
Cateterismo Cardíaco/tendências , Cardiologia/tendências , Angiografia Coronária/tendências , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Intervenção Coronária Percutânea/tendências , Difusão de Inovações , Cardiopatias/fisiopatologia , Humanos
5.
JAMA Neurol ; 77(7): 878-886, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32282016

RESUMO

Importance: Recent epidemiologic and therapeutic advances have transformed understanding of the role of and therapeutic approach to patent foramen ovale (PFO) in ischemic stroke. Patent foramen ovale is likely responsible for approximately 5% of all ischemic strokes and 10% of those occurring in young and middle-aged adults. Observations: Randomized clinical trials have demonstrated that, to prevent recurrent ischemic stroke in patients with PFO and an otherwise-cryptogenic index ischemic stroke, PFO closure is superior to antiplatelet medical therapy alone; these trials have provided some evidence that, among medical therapy options, anticoagulants may be more effective than antiplatelet agents. Conclusions and Relevance: These new data indicate a need to update classification schemes of causative mechanisms in stroke, developed in an era in which an association between PFO and stroke was viewed as uncertain. We propose a revised general nomenclature and classification framework for PFO-associated stroke and detailed revisions for the 3 major stroke subtyping algorithms in wide use.


Assuntos
Forame Oval Patente/complicações , AVC Isquêmico/classificação , AVC Isquêmico/etiologia , Humanos , Terminologia como Assunto
6.
Cardiol Young ; 30(3): 444-445, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32066513

RESUMO

We report a case of Figulla-II Occlutech septal occluder malposition with residual shunt at posteriosuperior margin of an atrial septal defect. Improvising its bioptome type delivery cable, same system was used to recapture the device and redeploy it successfully. This report highlights a potential malfunction of Figulla-II Occlutech disc and the advantage of its delivery system for retrieval of the device.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Falha de Prótese , Dispositivo para Oclusão Septal , Adolescente , Ecocardiografia Transesofagiana , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Desenho de Prótese , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 94(4): 598-606, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31441590
9.
Catheter Cardiovasc Interv ; 93(5): 859-874, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30896894

RESUMO

Until recently, evidence to support Patent Foramen Ovale (PFO) closure for secondary prevention of recurrent stroke has been controversial. Publication of high-quality evidence from randomized clinical trials and the subsequent FDA approval of two devices for percutaneous PFO closure is expected to increase the volume of PFO closure procedures not only in the United States but worldwide. As this technology is disseminated broadly to the public, ensuring the safe and efficacious performance of PFO closure is essential to mitigate risk and avoid unnecessary procedures. This document, prepared by a multi-disciplinary writing group convened by the Society for Cardiovascular Angiography and Interventions and including representatives from the American Academy of Neurology, makes recommendations for institutional infrastructure and individual skills necessary to initiate and maintain an active PFO/stroke program, with emphasis on shared decision making and patient-centered care.


Assuntos
Cateterismo Cardíaco , Educação de Pós-Graduação em Medicina , Embolia Paradoxal/prevenção & controle , Forame Oval Patente/terapia , Neurologistas/educação , Prevenção Secundária/educação , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Tomada de Decisão Clínica , Consenso , Embolia Paradoxal/diagnóstico por imagem , Embolia Paradoxal/etiologia , Embolia Paradoxal/fisiopatologia , Medicina Baseada em Evidências , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/fisiopatologia , Humanos , Segurança do Paciente , Recidiva , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Resultado do Tratamento
10.
Pediatr Cardiol ; 40(3): 664-667, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30758519

RESUMO

Extracorporeal membrane oxygenation complications involving vascular injury or intracardiac thrombosis in neonates are rare. We present a series of unique complications and describe their variable treatments.


Assuntos
Oxigenação por Membrana Extracorpórea/efeitos adversos , Procedimentos Cirúrgicos Vasculares/métodos , Angiografia/métodos , Ecocardiografia/métodos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino
11.
Catheter. cardiovasc. interv ; 92(7): 1323-1328, Dec. 2018. ilus, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247634

RESUMO

BACKGROUND: Variable patent ductus arteriosus (PDA) morphology and the need to close PDAs in small size patients has led physicians to use Amplatzer Vascular Plugs (AVP) and recently available Amplatzer Duct Occluder II - Additional Sizes (ADO II AS). The purpose of this study was to analyze the safety, efficacy, and complication rates of the ADO II AS and AVPs, specifically AVP II. METHODS: All patients undergoing PDA closure with an AVP or ADO II AS from 2011 to 2016 were included. Clinical, echocardiographic, and angiographic data were collected and reviewed. RESULTS: Four hundred and sixty-nine patients were included. Median age was 27 months (0.75­852) and the median weight was 11.4 kg (1­92). There were 51 patients ≤5 kg. Type A PDA was most common in 48% (n = 225), followed by type E (27.5%, n = 129), type D (13%, n = 61), type C (10.2%, n = 48), and type B (1.3%, n = 6). Devices included AVP II (n = 421), ADO II AS (n = 30), and AVP IV (n = 18), left pulmonary artery stenosis occurred in 4.3% (n = 20). One patient required surgery for severe stenosis; the remaining cases were mild and required no intervention. Device embolization occurred in 3 patients (10%) with the ADO II AS. Successful device closure was achieved in 98.9% of cases. CONCLUSIONS: The AVP II was highly effective for closing PDAs in smaller babies with varying morphologies and is safe when used in small sized patients with relatively low risk of complications. More studies are warranted to clarify the risks of ADO II AS.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Permeabilidade do Canal Arterial , Cardiopatias Congênitas
12.
Catheter Cardiovasc Interv ; 92(7): 1323-1328, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30196542

RESUMO

BACKGROUND: Variable patent ductus arteriosus (PDA) morphology and the need to close PDAs in small size patients has led physicians to use Amplatzer Vascular Plugs (AVP) and recently available Amplatzer Duct Occluder II - Additional Sizes (ADO II AS). The purpose of this study was to analyze the safety, efficacy, and complication rates of the ADO II AS and AVPs, specifically AVP II. METHODS: All patients undergoing PDA closure with an AVP or ADO II AS from 2011 to 2016 were included. Clinical, echocardiographic, and angiographic data were collected and reviewed. RESULTS: Four hundred and sixty-nine patients were included. Median age was 27 months (0.75-852) and the median weight was 11.4 kg (1-92). There were 51 patients ≤5 kg. Type A PDA was most common in 48% (n = 225), followed by type E (27.5%, n = 129), type D (13%, n = 61), type C (10.2%, n = 48), and type B (1.3%, n = 6). Devices included AVP II (n = 421), ADO II AS (n = 30), and AVP IV (n = 18), left pulmonary artery stenosis occurred in 4.3% (n = 20). One patient required surgery for severe stenosis; the remaining cases were mild and required no intervention. Device embolization occurred in 3 patients (10%) with the ADO II AS. Successful device closure was achieved in 98.9% of cases. CONCLUSIONS: The AVP II was highly effective for closing PDAs in smaller babies with varying morphologies and is safe when used in small sized patients with relatively low risk of complications. More studies are warranted to clarify the risks of ADO II AS.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
Cardiol Young ; 28(7): 968-969, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29779503

RESUMO

Percutaneous pulmonary valve placement in patients with an anomalous coronary artery is rare and can be complicated by coronary artery compression. We report successful implantation of a percutaneous pulmonary valve in a patient with an anomalous left anterior descending artery.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Implante de Prótese de Valva Cardíaca , Criança , Angiografia Coronária , Vasos Coronários/cirurgia , Feminino , Humanos , Valva Pulmonar/cirurgia
15.
Catheter Cardiovasc Interv ; 92(5): 915-920, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-28303658

RESUMO

Advances in surgical techniques in tetralogy of Fallot (TOF) patients have improved survival of these patients into adulthood. The procedure requires right ventricular outflow tract or trans-annular patch with resultant pulmonary stenosis and/or regurgitation. As such, adult patients seen with this condition may have increasing right ventricular hypertrophy and/or right ventricular dilation. Recently, the Sapien XT valve (Edwards Lifesciences, CA) was approved by the FDA for pulmonary implantation. In some cases, advancing the valve in right ventricular outflow tract is difficult. This is a case series of delivering Sapien XT valves in TOF patients with severe pulmonary regurgitation and/or stenosis, using the anchor balloon, buddy wire, and the novel, wire and sheath techniques. © 2017 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Adulto , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Resultado do Tratamento , Adulto Jovem
16.
J Am Soc Echocardiogr ; 31(4): 381-404, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29066081

RESUMO

This document is 1 of 2 companion appropriate use criteria (AUC) documents developed by the American College of Cardiology, American Association for Thoracic Surgery, American Heart Association, American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. This document addresses the evaluation and use of multimodality imaging in the diagnosis and management of valvular heart disease, whereas the second, companion document addresses this topic with regard to structural heart disease. Although there is clinical overlap, the documents addressing valvular and structural heart disease are published separately, albeit with a common structure. The goal of the companion AUC documents is to provide a comprehensive resource for multimodality imaging in the context of valvular and structural heart disease, encompassing multiple imaging modalities. Using standardized methodology, the clinical scenarios (indications) were developed by a diverse writing group to represent patient presentations encountered in everyday practice and included common applications and anticipated uses. Where appropriate, the scenarios were developed on the basis of the most current American College of Cardiology/American Heart Association guidelines. A separate, independent rating panel scored the 92 clinical scenarios in this document on a scale of 1 to 9. Scores of 7 to 9 indicate that a modality is considered appropriate for the clinical scenario presented. Midrange scores of 4 to 6 indicate that a modality may be appropriate for the clinical scenario, and scores of 1 to 3 indicate that a modality is considered rarely appropriate for the clinical scenario. The primary objective of the AUC is to provide a framework for the assessment of these scenarios by practices that will improve and standardize physician decision making. AUC publications reflect an ongoing effort by the American College of Cardiology to critically and systematically create, review, and categorize clinical situations where diagnostic tests and procedures are utilized by physicians caring for patients with cardiovascular diseases. The process is based on the current understanding of the technical capabilities of the imaging modalities examined.


Assuntos
American Heart Association , Cardiologia , Doenças das Valvas Cardíacas/diagnóstico , Imagem Multimodal/normas , Sociedades Médicas , Cirurgia Torácica , Angiografia/normas , Ecocardiografia/normas , Doenças das Valvas Cardíacas/cirurgia , Humanos , Imagem Cinética por Ressonância Magnética/normas , Tomografia Computadorizada por Raios X/normas , Estados Unidos
17.
Pediatr Cardiol ; 38(7): 1332-1336, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28639149

RESUMO

The aim of the study was to evaluate the safety, feasibility, and economic benefit of a high-volume operator performing common interventional procedures in a rural region of the United States (U.S.). Rural areas of the U.S., even with well-equipped cardiac catheterization laboratories, may not have a full-time pediatric interventional cardiologist (PIC); this requires patients to travel out of state even for simple interventions. Since 2005, we have adopted a policy of performing cardiac catheterizations and common interventional procedures with a visiting PIC. We reviewed data of all patients who underwent cardiac catheterizations from May 2005 through March 2015 at our center. Variables analyzed were type of procedure, results, and follow-up six months after procedure. 197 catheterizations were performed, of which 80 were for single atrial septal defect (ASD), 29 for fenestrated ASD, 49 for patent ductus arteriosus (PDA), and 39 for other procedures. Device closure of single ASD was successful in 75 of 79 attempts and in 27 of 28 attempts for fenestrated ASD. PDA closure was successful in 45 of 46 attempts. Follow-up data of 6 months or more were available for 127 patients. All but two patients had no cardiovascular symptoms at 6 months. There were four minor complications and no major complications. With a technical success rate of 94.9% for single ASD closure, 97.8% for PDA closure, and results comparable to those of multi-institutional registries, cardiac catheterization and interventions can be performed safely with excellent results. Performing procedures in such an arrangement is safe, feasible, and economically beneficial.


Assuntos
Cateterismo Cardíaco/estatística & dados numéricos , Cardiopatias Congênitas/cirurgia , Preços Hospitalares/estatística & dados numéricos , Serviços de Saúde Rural/estatística & dados numéricos , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/economia , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Masculino , Sistema de Registros , Estudos Retrospectivos , Serviços de Saúde Rural/economia , Resultado do Tratamento , Estados Unidos , Adulto Jovem
18.
Front Surg ; 4: 9, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28321396

RESUMO

As surgical and catheter interventions advance, patients with congenital heart disease are now offered alternative treatment options that cater to their individual needs. Furthermore, collaboration between interventional cardiologists and cardiac surgeons have led to the development of hybrid procedures, using the best techniques of each respective field to treat these complex cardiac entities from initial treatment in the pediatric patient to repeat intervention in the adult. We present a review of the increased popularity and trend in hybrid procedures in congenital heart disease without the use of cardiopulmonary bypass.

19.
Pediatr Cardiol ; 38(3): 575-581, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27995292

RESUMO

Perventricular Melody valve placement has been described as a bailout approach or alternative RVOT approach in patients >30 kg. We present three patients <20 kg and two patients with limited venous access, where we electively performed the perventricular approach. Retrospective analysis of patients <30 kg and vascular access limitation undergoing elective hybrid pulmonary valve replacement were reviewed. The subcostal approach was performed without sternotomy with the sheath introduced through the diaphragmatic surface of the right ventricle. Diagnoses included tetralogy of Fallot (n = 3) and truncus arteriosus (n = 2). Mean weight was 16.2 kg (range 4.7-28.1 kg). Four patients had RV-PA conduits (size: 14-21 mm), and the fifth patient had a transannular patch. All patients met criteria for surgical valve replacement. Technical success was 100%. In two patients with absent pulmonary valve, the stent migrated during advancement of the delivery sheath. These stents were anchored in the distal main pulmonary artery (n = 1) or branch pulmonary artery (n = 1) without sequela. Tricuspid valve chordal injury occurred in one patient, where transesophageal echocardiogram (TEE) was not utilized. No patient required conversion to cardiopulmonary bypass. One patient with absent pulmonary valve died on follow-up as a consequence of severe airway compromise. Our initial experience demonstrates that the perventricular valve can be placed safely in small-sized patients. Advancement of the melody ensemble may be difficult and may cause stent migration. We conclude that the technique is feasible in small-sized patients and that prevention of complications includes placement of the stent at the time of the valve and TEE assistance in reducing tricuspid valve injury.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Tronco Arterial/cirurgia , Criança , Pré-Escolar , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas , Humanos , Lactente , Desenho de Prótese , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento
20.
Circulation ; 133(18): 1738-46, 2016 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-27002094

RESUMO

BACKGROUND: Transcatheter closure of secundum atrial septal defects (ASD) using the Amplatzer septal occluder is generally safe and effective, but erosion into the pericardial space or aorta has been described. Although the absolute risk of this complication is low, there has been no assessment of relative risk factors. METHODS AND RESULTS: All erosions reported to St. Jude Medical after ASD closure with an Amplatzer septal occluder (cases) were compared with controls (matched 2:1) who underwent ASD closure but did not develop an erosion. A total of 125 erosions were reported between 2002 and 2014, including 95 with an available echocardiogram. The median duration from implant to erosion was 14 days, but was >1 year in 16 patients. Nine patients (all age ≥17 years) who died were more likely to have an oversized device, and to have erosion into the aorta, than survivors. Aortic or superior vena cava rim deficiencies were more common in cases than in controls. In addition, larger balloon-sized ASD diameter, Amplatzer septal occluder device size, and device size-ASD diameter difference, and smaller weight:device size ratio were associated with erosion. On multivariable analysis, deficiency of any rim, device >5 mm larger than ASD diameter, and weight:device size ratio were associated with erosion. CONCLUSIONS: In addition to aortic rim deficiency, which was almost universal among erosion cases, there were several relative risk factors for erosion after ASD closure with the Amplatzer septal occluder device. To understand the mechanisms of and absolute risk factors for this uncommon but serious complication, an adequately powered prospective study with thorough echocardiographic evaluation will be critical.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Estudos de Casos e Controles , Criança , Estudos de Coortes , Feminino , Comunicação Interatrial/diagnóstico , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Fatores de Risco , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...