Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 104: 174-187, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36463582

RESUMO

At the Photo Injector Test facility at DESY in Zeuthen (PITZ), an R&D platform for electron FLASH and very high energy electron radiation therapy and radiation biology is being prepared (FLASHlab@PITZ). The beam parameters available at PITZ are worldwide unique. They are based on experiences from 20 + years of developing high brightness beam sources and an ultra-intensive THz light source demonstrator for ps scale electron bunches with up to 5 nC bunch charge at MHz repetition rate in bunch trains of up to 1 ms length, currently 22 MeV (upgrade to 250 MeV planned). Individual bunches can provide peak dose rates up to 1014 Gy/s, and 10 Gy can be delivered within picoseconds. Upon demand, each bunch of the bunch train can be guided to a different transverse location, so that either a "painting" with micro beams (comparable to pencil beam scanning in proton therapy) or a cumulative increase of absorbed dose, using a wide beam distribution, can be realized at the tumor. Full tumor treatment can hence be completed within 1 ms, mitigating organ movement issues. With extremely flexible beam manipulation capabilities, FLASHlab@PITZ will cover the current parameter range of successfully demonstrated FLASH effects and extend the parameter range towards yet unexploited short treatment times and high dose rates. A summary of the plans for FLASHlab@PITZ and the status of its realization will be presented.


Assuntos
Elétrons , Neoplasias , Humanos , Radiobiologia
2.
Radiat Res ; 196(6): 658-667, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34478547

RESUMO

Recently, a new technology of low-energy ultrashort-pulsed electron beam (UPEB) accelerators has been developed opening new directions for radiobiology and biomedical research. The purpose of this study was to reveal the lethal dose, LD50 (lethal dose, 50%) delivered by low-energy UPEB whole-body exposure on an organismal level. Wistar rats were exposed to low-energy UPEB whole-body irradiation with different doses and pulse repetition rates to find the LD50 and in silico computer simulations were performed to conduct numerical dose calculations. Survival rate, body weight and water consumption were monitored over the 30-day observation period postirradiation. The LD50 was observed after a 2 Gy dose and pulse repetition rate of 2 Hz. In this group, 50% of the animals survived 30 days postirradiation. The groups of animals exposed to low-energy UPEB radiation at higher doses and pulse repetition rates demonstrated higher mortality rates. We demonstrated that the LD50 dose for the low-energy UPEB whole body irradiation in Wistar rats corresponds to 2 Gy with a pulse repetition rate of 2 Hz. Moreover, we showed that the pulse repetition rate is a very important parameter in the experiments with UPEB and should be assessed in the experiments with such kind of novel irradiation sources.


Assuntos
Lasers , Irradiação Corporal Total , Animais , Simulação por Computador , Elétrons , Dose Letal Mediana , Masculino , Ratos , Ratos Wistar
3.
Acta Crystallogr A Found Adv ; 71(Pt 3): 291-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25921497

RESUMO

A pair of enantiomer crystals is used to demonstrate how X-ray phase measurements provide reliable information for absolute identification and improvement of atomic model structures. Reliable phase measurements are possible thanks to the existence of intervals of phase values that are clearly distinguishable beyond instrumental effects. Because of the high susceptibility of phase values to structural details, accurate model structures were necessary for succeeding with this demonstration. It shows a route for exploiting physical phase measurements in the crystallography of more complex crystals.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...