Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Echocardiography ; 39(5): 732-734, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35342973

RESUMO

We present a case of a 61-year-old female who, after undergoing frozen elephant trunk surgery, was found to have an unexpected left ventricular pseudoaneurysm on transthoracic echocardiogram. The pseudoaneurysm was caused by the left ventricular vent catheter constantly impinging the LV wall of the beating heart during surgery. Contrast echocardiography, cardiac magnetic resonance imaging and computed tomography (CT) imaging confirmed the diagnosis and served for follow-up demonstrating the narrow neck and outpouching structure on the apical lateral wall. The patient remains asymptomatic two years after the operation and is being followed up with echocardiography and CT imaging.


Assuntos
Falso Aneurisma , Falso Aneurisma/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
2.
J Ultrasound ; 24(4): 529-533, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32141044

RESUMO

The clinical success of uterine artery embolization is determined by its endpoint. An aggressive UAE could lead to endometritis and increases the risk of unintended embolization of other organs. Conversely, an incomplete procedure may result in a poor clinical outcome due to regrowth of the fibroids. We present a case with innovative use of intraoperative contrast-enhanced ultrasonography (CEUS) for the assessment of vascularity of the targeted fibroid to determine the endpoint of embolization perioperatively. We aim to report a case of the use of intraoperative CEUS during UAE to highlight the potential pitfall of its use and provide a review of its application in the literature. Our case affirms the reported usefulness and the practical feasibility to assess the vascularity of fibroids during UAE and highlights that caution should be made by operators in cases of multiple fibroids.


Assuntos
Leiomioma , Embolização da Artéria Uterina , Feminino , Humanos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Resultado do Tratamento , Ultrassonografia
5.
Indian J Radiol Imaging ; 26(2): 249-53, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27413275

RESUMO

PURPOSE: The OUTBACK(®) catheter is a reentry device that enables reentry into a vessel lumen from the subintimal space during subintimal angioplasty. It is reserved for cases where reentry has not been possible using conventional wire and catheter techniques. We report a two-center experience in recanalization of the chronic total occlusions of the common iliac (CIA) and the superficial femoral artery (SFA) using the OUTBACK(®) catheter in cases where other techniques were unsuccessful. MATERIAL AND METHODS: All cases where recanalization was performed using the OUTBACK(®) reentry catheter between January 2010 to January 2015 were retrospectively identified and included in this study. 21 patients were identified. The indication for intervention in these cases included claudication and critical leg ischemia. In all cases, conventional recanalization could not be successfully achieved. RESULTS: The OUTBACK(®) catheter was used to recanalize 10 SFA occlusion and 9 CIA occlusions. In 19 patients (90%), reentry into true arterial lumen was successfully achieved. 17 patients had their recanalization through the transfemoral approach whereas 2 patients had a transpopliteal artery approach. In 2 patients, reentry into the true lumen could not be achieved using the OUTBACK(®) catheter due to patient's intolerability for the procedure and severe atherosclerotic calcified plaques. There was 100% patency of the vessel intervened on Duplex ultrasound at 24 months of follow up. 16 patients (84%) remained asymptomatic and 2 patients (10.5%) reported worsening of their symptoms due to the development of new lesions within the arterial system. CONCLUSION: The OUTBACK(®) catheter is an effective and safe technique for reentry into the vessel lumen when conventional techniques fail.

7.
J Intensive Care Soc ; 16(1): 71-74, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28979378

RESUMO

An extensive caval thrombus was incidentally detected in a neurosurgical patient by clinician-delivered critical care echocardiography. Recent intracranial haemorrhage prevented therapeutic anticoagulation; the very proximal nature of the thrombus precluded standard deployment of an inferior vena cava filter. We describe the novel radiological technique employed to manage the thrombus, and examine whether a thermoregulatory central venous catheter inserted as part of standard neuro-critical care may have contributed to the risk and extent of the caval thrombus.

8.
Semin Intervent Radiol ; 31(4): 307-12, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25435655

RESUMO

Because of the severe morbidity and mortality associated with diabetes, diabetic foot care is an essential component of a peripheral vascular service. The goal of this article is to describe the vascular diabetic foot care pathway and how the coordinated foot care service for diabetic patients is delivered at King's College Hospital, London.

9.
Cardiovasc Intervent Radiol ; 33(3): 590-5, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19937022

RESUMO

Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, with modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.


Assuntos
Esclerose Lateral Amiotrófica/fisiopatologia , Esclerose Lateral Amiotrófica/cirurgia , Gastrostomia/instrumentação , Implantação de Prótese/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia Intervencionista , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...