Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Indian Soc Periodontol ; 19(4): 440-3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26392695

RESUMO

Autogenous bone grafts have been considered the gold standard for bone grafting procedures. This case report describes the management of a two wall defect by utilizing the autogenous bone graft obtained during removal of ledges as a part of osteoplasty procedure. The bone was removed with a sickle scaler, and sufficient amounts of bone graft material were obtained to fill a two wall defect distal to left mandibular first molar.

2.
J Indian Soc Periodontol ; 19(1): 32-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25810590

RESUMO

BACKGROUND: The aim of this study was to evaluate the mechanical properties of the platelet-rich fibrin (PRF) membrane and to compare these properties with that of commercially available collagen membranes used for guided tissue regeneration (GTR) procedures. Scanning electron microscopic (SEM) examination of PRF membrane was also performed to determine the cell distribution pattern within the different regions of the membrane. MATERIALS AND METHODS: Modulus of elasticity and hardness of (i) PRF membrane (ii) bovine collagen membrane and (iii) fish collagen membrane were assessed by performing surface indentation test using T1 950 Triboindenter. The in vitro degradation tests were conducted by placing the (i) PRF membrane (ii) bovine collagen membrane and (iii) fish collagen membrane of equal sizes (10 mm × 5 mm) in 5 ml of pH 7.4 phosphate buffer solution on a shaker set at 40 rpm for 1-week. The degradation profiles were expressed as the accumulated weight losses of the membrane. SEM evaluation of the PRF membrane was done under both low and high magnification. RESULTS: Young's Modulus of elasticity was found to be 0.35 GPa for PRF membrane, 2.74 GPa for bovine collagen membrane and 1.92 GPa for fish collagen. The hardness was 10.67 MPa for PRF membrane, 110.7 MPa for bovine collagen membrane and 90.5 MPa for fish collagen membrane. PRF membrane degraded by about 36% of initial weight after a 1-week in vitro shaking test. Fish collagen membrane degraded by about 8% of initial weight, bovine collagen membrane degraded by about 3% of initial weight. Dense clusters of platelets formed due to extensive aggregation, and few leukocytes were observed in buffy coat area. CONCLUSIONS: The preliminary findings from the assessment of the mechanical properties of PRF membrane showed that it was lacking in several desired properties when compared to commercially available collagen membranes. Lack of rigidity and faster degradation may limit its application in GTR procedures.

3.
J Clin Diagn Res ; 8(11): ZC43-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25584315

RESUMO

BACKGROUND: Horizontal bone loss is the most common periodontal problem confronting the clinician but has received little attention. Platelet rich fibrin (PRF) is a second generation platelet concentrate. The platelets, leucocytes, growth factors and cytokines contained within PRF make it a healing biomaterial with tremendous potential for bone and soft tissue regeneration. AIM: This interventional clinical trial evaluates the clinical effectiveness of Autologous Platelet Rich Fibrin (PRF) in the management of horizontal bony defects. SETTINGS AND DESIGN: Department of Periodontics. Design was Non Randomized Clinical Trial with split mouth design. MATERIALS AND METHODS: A total of 45 sites with horizontal bone loss in 15 patients were studied, 15 sites were treated with PRF gel (experimental group I) and 15 sites were treated with PRF gel and PRF membrane (experimental group II). Control group (15 sites) were treated with open flap debridement. STATISTICAL ANALYSIS: All the parameters were assessed at baseline and after nine months which included Pocket Depth (PD), Clinical Attachment level (CAL), Gingival Recession (REC) and Relative Crest Height (RCH). The mean changes at baseline and after 9 months within each group were compared using Wilcoxon Signed Ranks Test. The mean changes for each parameter between groups were compared using Kruskal Wallis Test. RESULTS: Re-evaluation at nine months revealed that all groups showed a significant reduction in probing depth (1.1±0.38 mm in control, 1.73±0.53 mm in group I, 1.7±0.45 mm in group II)(p<0.05) and clinical attachment gain (0.86±0.58 mm in control, 1.56±0.62 mm in group I, 1.7±0.52 in group II)(p<0.05) as compared to baseline. Intergroup comparisons of reduction in probing depth and clinical attachment gain showed significant differences in the experimental groups as compared to control (p<0.05), but there was no significant difference between the experimental groups (p>0.05). There was no significant difference in gingival recession and radiographic bone levels at 9 months post surgery (p>0.05) in all the three groups. CONCLUSION: Within the limitations of this study, it can be concluded that, clinically the use of PRF in both gel and membrane form is more effective than open flap debridement alone in the management of horizontal periodontal defects at nine months post surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...