Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Environ Res ; 181: 108959, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31784080

RESUMO

The Brazilian coast of the Rio de Janeiro State has bays of great economic, ecological and social importance. However, these ecosystems have been suffering intense anthropogenic influence, mainly due to the contamination by polycyclic aromatic hydrocarbons (PAHs) from urban-industrial activities. Moreover, PAHs are organic pollutants of high toxicity and carcinogenicity causing global concern to human and environmental health. This study evaluated on catfish (Genidens genidens) a set of key parameters (sex, morphometric traits, condition factor (K), PAH metabolites in gallbladder, frequency of micronucleus (MN) and erythrocytic nuclear abnormalities (ENA) in blood. In addition we also evaluated histopathological hepatic effects, Ethoxyresorufin-O-deethylase (EROD) activity and Benzo(a)pyrene diol epoxide (BPDE)-DNA adducts) in liver samples, in order to indicate the fish health status and environmental pollution levels of three main Bays (Guanabara, Sepetiba and Ilha Grande) of the Rio de Janeiro State, in the Southeast of Brazil. In general, the worst physical and metabolic conditions in catfishes were evidenced in Guanabara Bay, possibly indicating the highest level of contamination by PAHs. Contrary evidence was observed in Ilha Grande Bay, showing lower biological changes in G. genidens. However in Sepetiba Bay, the influence of PAHs contamination showed the highest hepatic lesions in catfishes, prevailing foci of cellular alterations, megalocytic hepatosis and hydropic vacuolations. The employability of a set of biomarkers on catfish was efficient for screening pollution for PAHs in tropical environments. This reinforces the need for effective actions of monitoring and conservation strategies of bays of the Rio de Janeiro State (Brazil), in order to ensure quality and health to both human and environment.


Assuntos
Peixes-Gato , Monitoramento Ambiental , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Animais , Baías , Brasil , Ecossistema
2.
J Appl Oral Sci ; 20(4): 467-71, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23032210

RESUMO

OBJECTIVE: The aim of this study was to evaluate, by PCR-RFLP and real-time PCR, the yield and quality of genomic DNA collected from buccal cells by mouthwash after different storage times at room temperature. MATERIAL AND METHODS: A group of volunteers was recruited to collect buccal cells using a mouthwash solution. The collected solution was divided into 3 tubes, one tube were used for immediate extraction and the remaining received ethanol and were kept at room temperature for 4 and 8 days followed by dna extraction. The concentration, purity and integrity of the dna were determined using spectrophotometry and electrophoresis. DNA quality differences among the three incubation times were also evaluated for genotyping EGF +61 a/g (rs 4444903) polymorphism by PCR-RFLP and for IRF6 polymorphism (rs 17015215) using real-time PCR. RESULTS: There was no significant difference of dna yield (p=0.75) and purity (p=0.86) among the three different incubation times. DNA obtained from different incubation times presented high-molecular weight. The PCR-RFLP and real time pcr reactions were successfully performed for all DNA samples, even those extracted after 8 days of incubation. All samples genotyped by real-time pcr presented c allele for irf6 gene polymorphism (homozygous: cc; heterozygous: Ct) and the C allele was used as a reference for Ct values. The samples presented the same genotype for the different times in both techniques. CONCLUSION: We demonstrated that the method described herein is simple and low cost, and that DNA can be extracted and pcr amplified after storage in mouthwash solution at room temperature.


Assuntos
DNA/isolamento & purificação , Técnicas de Genotipagem/métodos , Boca/citologia , Polimorfismo de Fragmento de Restrição/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Adulto , Análise de Variância , Eletroforese , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Saliva , Espectrofotometria , Fatores de Tempo
3.
J. appl. oral sci ; 20(4): 467-471, July-Aug. 2012. ilus, graf
Artigo em Inglês | LILACS | ID: lil-650625

RESUMO

OBJECTIVE: The aim of this study was to evaluate, by PCR-RFLP and real-time PCR, the yield and quality of genomic DNA collected from buccal cells by mouthwash after different storage times at room temperature. MATERIAL AND METHODS: A group of volunteers was recruited to collect buccal cells using a mouthwash solution. The collected solution was divided into 3 tubes, one tube were used for immediate extraction and the remaining received ethanol and were kept at room temperature for 4 and 8 days followed by dna extraction. The concentration, purity and integrity of the dna were determined using spectrophotometry and electrophoresis. DNA quality differences among the three incubation times were also evaluated for genotyping EGF +61 a/g (rs 4444903) polymorphism by PCR-RFLP and for IRF6 polymorphism (rs 17015215) using real-time PCR. RESULTS: There was no significant difference of dna yield (p=0.75) and purity (p=0.86) among the three different incubation times. DNA obtained from different incubation times presented high-molecular weight. The PCR-RFLP and real time pcr reactions were successfully performed for all DNA samples, even those extracted after 8 days of incubation. All samples genotyped by real-time pcr presented c allele for irf6 gene polymorphism (homozygous: cc; heterozygous: Ct) and the C allele was used as a reference for Ct values. The samples presented the same genotype for the different times in both techniques. CONCLUSION: We demonstrated that the method described herein is simple and low cost, and that DNA can be extracted and pcr amplified after storage in mouthwash solution at room temperature.


Assuntos
Adulto , Feminino , Humanos , Pessoa de Meia-Idade , DNA , Técnicas de Genotipagem/métodos , Boca/citologia , Polimorfismo de Fragmento de Restrição/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Análise de Variância , Eletroforese , Reprodutibilidade dos Testes , Saliva , Espectrofotometria , Fatores de Tempo
4.
Sci Total Environ ; 370(2-3): 382-90, 2006 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16914185

RESUMO

Sugarcane workers in Brazil are exposed to various genotoxic compounds, including polycyclic aromatic hydrocarbons (PAHs), derived from an incomplete combustion process of burnt sugarcane fields. The effects of the occupational exposure to sugarcane fields burning were measured in urine samples of sugarcane workers from the northwest of the State of São Paulo when exposed (harvesting) and when non-exposed (non-harvesting). The urinary levels of 1-hydroxypyrene (1-OHP) and the influence of the genetic polymorphisms CYP1A1, GSTM1, GSTT1 and GSTP1 were evaluated. Our results showed that the 1-OHP levels were significantly higher (P<0.0000) in the exposed sugarcane workers (0.318 mumol mol(-1) creatinine) than in the non-exposed workers (0.035 mumol mol(-1) creatinine). In an unvaried analysis, no influence regarding the polymorphisms was observed. However, multivariate regression analysis showed that the CYP1A1()4 polymorphism in the exposed group, and age and the GSTP1 polymorphism in the non-exposed group significantly influenced urinary 1-OHP excretion levels (P<0.10). The same group of sugarcane workers was significantly more exposed to PAHs during the harvesting period than during the non-harvesting period.


Assuntos
Exposição Ocupacional , Polimorfismo Genético , Pirenos/metabolismo , Saccharum , Adulto , Idoso , Agricultura , Biomarcadores/urina , Brasil , Citocromo P-450 CYP1A1/genética , Monitoramento Ambiental , Feminino , Glutationa S-Transferase pi/genética , Glutationa Transferase/genética , Humanos , Masculino , Pessoa de Meia-Idade , Urinálise
5.
Mutat Res ; 547(1-2): 35-40, 2004 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-15013696

RESUMO

CYP1A1 polymorphisms have been associated with a higher risk to develop lung cancer, particularly in Japanese. The type and the frequency of the polymorphisms can vary according to the ethnicity. In the present study, we aimed to determine the frequency of CYP1A1(*)2B and (*)4, and to look for other possible polymorphisms that may happen in exon 7 in individuals from Rio de Janeiro, an ethnic mixed population from Brazil. We developed a PCR-SSCP method for screening the genomic polymorphic region from 2289 to 2645 bp. Seven different migration patterns were found among 405 individuals, 130 healthy blood donors and 275 outpatients from Hospital Universitário Pedro Ernesto located in Rio de Janeiro. Five of the migration patterns corresponded to the genotypes: (*)1/(*)1 (the wild type); (*)1/(*)2B; (*)1/(*)4, (*)2B/(*)4 (heterozygous polymorphic) and (*)2B/(*)2B (homozygous polymorphic). Two other patterns corresponded to gene alterations not yet published: a C > T transition localized at the position 2461, and a C > T transition localized at position 2445. The genotype frequencies of the studied polymorphisms were: for CYP1A1(*)2B - 83.7% to (*)1/(*)1, 15.1% to (*)1/(*)2B and 1.2% to (*)2B/(*)2B; for CYP1A1(*)4 - 93.1% to (*)1/(*)1, 6.9% to (*)1/(*)4. The distribution of CYP1A1(*)2B and (*)4 genotypes combined were similar between white and non-white individuals. However, when the non-white individuals were stratified between blacks and mulattos, and then compared with white, black individuals showed a higher frequency of the wild type genotype (P = 0.008) and a lower frequency of genotype (*)1/(*)4 (P = 0.026). Additionally, when black and mulatto individuals were compared, blacks had a higher frequency of the wild type genotype (P = 0.008) and a lower frequency of the(*)1/(*)2B genotype (P = 0.0008), showing a different ethnic distribution of CYP1A1 polymorphisms.


Assuntos
Citocromo P-450 CYP1A1/genética , Éxons , Variação Genética , Reação em Cadeia da Polimerase , Polimorfismo Genético , Polimorfismo Conformacional de Fita Simples , Pareamento de Bases , População Negra , Brasil/etnologia , Frequência do Gene , Genética Populacional , Humanos , População Branca
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...