Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Muscle Nerve ; 51(4): 592-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25131376

RESUMO

INTRODUCTION: We assessed the yield of high-resolution ultrasonography (HRUS) in patients with clinically definite carpal tunnel syndrome (CTS) and normal nerve conduction studies (NCS). METHODS: This blinded, prospective, cross-sectional study involved 35 patients (60 hands) with clinically definite CTS and normal NCS, and 20 controls (40 hands). Cross-sectional area (CSAs) of the median nerve at the level of the pisiform bone and flexor retinaculum thickness (FRT) were measured. RESULTS: CSA was abnormal in 48.6% of patients (confidence interval 32.0-65.2%, P = 0.95). FRT was increased in only 34.3% (18.3-49.7%), but was independently abnormal in 2 patients. CSA abnormalities correlated with positive provocative tests and sensory loss. The HRUS changes were mild. CONCLUSIONS: HRUS confirms clinically diagnosed CTS in about half of the patients with normal NCS.


Assuntos
Síndrome do Túnel Carpal/diagnóstico por imagem , Mãos/diagnóstico por imagem , Nervo Mediano/diagnóstico por imagem , Condução Nervosa/fisiologia , Adulto , Estudos Transversais/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia , Adulto Jovem
2.
Radiother Oncol ; 112(1): 128-32, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24997990

RESUMO

PURPOSE: To propose single-isocenter dynamic conformal arcs (SIDCA), a novel technique for radiosurgery of multiple brain metastases, and to compare SIDCA with volumetric modulated arc therapy (VMAT) and multiple-isocenter dynamic conformal arcs (MIDCA) for plan quality. METHODS AND MATERIALS: SIDCA, MIDCA, and VMAT plans were created on 6 patients with 3-5 metastases. Plans were evaluated using Radiation Therapy Oncology Group conformity index (RCI), Paddick conformity index (PCI), gradient index (GI), volumes that received more than 100% (V(100%)), 50% (V(50%)), 25% (V(25%)) and 10% (V(10%)) of prescription dose, total monitor units (MUs), and delivery time (DT). RESULTS: SIDCA achieved conformal plans (RCI = 1.38 ± 0.12, PCI = 0.72 ± 0.06) with steep dose fall-off (GI = 3.97 ± 0.51). MIDCA plans had comparable plan quality and MUs as SIDCA, but 52% longer DT. The VMAT plans had better conformity (RCI = 1.15 ± 0.09, p < 0.01 and PCI = 0.86 ± 0.06, p < 0.01) than SIDCA, worse GI (4.34 ± 0.46, p < 0.01), higher V(25%) (p = 0.05) and V(10%) (p = 0.02), 49% less MUs and 46% shorter DT. CONCLUSIONS: All three techniques achieved conformal plans with steep dose fall-off from targets. SIDCA plans had similar plan quality as MIDCA but more efficient to delivery. SIDCA plans had lower peripheral dose spread than VMAT; VMAT plans had better conformity and faster delivery time than SIDCA.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/radioterapia , Humanos , Estudos Retrospectivos
3.
Int J Radiat Oncol Biol Phys ; 85(1): 230-6, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22554583

RESUMO

PURPOSE: To study the impact of daily rotations and translations of the prostate on dosimetric coverage during radiation therapy (RT). METHODS AND MATERIALS: Real-time tracking data for 26 patients were obtained during RT. Intensity modulated radiation therapy plans meeting RTOG 0126 dosimetric criteria were created with 0-, 2-, 3-, and 5-mm planning target volume (PTV) margins. Daily translations and rotations were used to reconstruct prostate delivered dose from the planned dose. D95 and V79 were computed from the delivered dose to evaluate target coverage and the adequacy of PTV margins. Prostate equivalent rotation is a new metric introduced in this study to quantify prostate rotations by accounting for prostate shape and length of rotational lever arm. RESULTS: Large variations in prostate delivered dose were seen among patients. Adequate target coverage was met in 39%, 65%, and 84% of the patients for plans with 2-, 3-, and 5-mm PTV margins, respectively. Although no correlations between prostate delivered dose and daily rotations were seen, the data showed a clear correlation with prostate equivalent rotation. CONCLUSIONS: Prostate rotations during RT could cause significant underdosing even if daily translations were managed. These rotations should be managed with rotational tolerances based on prostate equivalent rotations.


Assuntos
Campos Eletromagnéticos , Movimento , Próstata/efeitos da radiação , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Próstata/anatomia & histologia , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Rotação , Carga Tumoral
4.
J Appl Clin Med Phys ; 12(3): 3398, 2011 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-21844848

RESUMO

The purpose of this study was to determine the dosimetric impact of density variations observed in water-equivalent solid slabs. Measurements were performed using two 30 cm × 30 cm water-equivalent slabs, one being 4 cm think and the other 5 cm thick. The location and extent of density variations were determined by computed tomography (CT) scans. Additional imaging measurements were made with an amorphous silicon megavoltage portal imaging device and an ultrasound unit. Dosimetric measurements were conducted with a 2D ion chamber array, and a scanned diode in water. Additional measurements and calculations were made of small rectilinear void inhomogeneities formed with water-equivalent slabs, using a 2D ion chamber array and the convolution superposition algorithm. Two general types of density variation features were observed on CT images: 1) regions of many centimeters across, but typically only a few millimeters thick, with electron densities a few percent lower than the bulk material, and 2) cylindrical regions roughly 0.2 cm in diameter and up to 20 cm long with electron densities up to 5% lower than the surrounding material. The density variations were not visible on kilovoltage, megavoltage or ultrasound images. The dosimetric impact of the density variations were not detectable to within 0.1% using the 2D ion chamber array or the scanning photon diode at distances 0.4 cm to 2 cm beyond the features. High-resolution dosimetric calculations using the convolution-superposition algorithm with density corrections enabled on CT-based datasets showed no discernable dosimetric impact. Calculations and measurements on simulated voids place the upper limit on possible dosimetric variations from observed density variations at much less than 0.6%. CT imaging of water-equivalent slabs may reveal density variations which are otherwise unobserved with kV, MV, or ultrasound imaging. No dosimetric impact from these features was measureable with an ion chamber array or scanned photon diode. Consequently, they were determined to be acceptable for all clinical use.


Assuntos
Fótons , Radiometria/métodos , Água/química , Algoritmos , Humanos , Íons , Imagens de Fantasmas , Efeitos da Radiação , Radiometria/instrumentação , Radioterapia de Alta Energia , Silício/química , Tomografia Computadorizada por Raios X , Ultrassonografia , Ecrans Intensificadores para Raios X
5.
Eur J Nucl Med Mol Imaging ; 38(5): 874-83, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21174088

RESUMO

PURPOSE: Improved data collection methods have improved absorbed dose estimation by tracking activity distributions and tumor extent at multiple time points, allowing individualized absorbed dose estimation. Treatment with tositumomab and (131)I-tositumomab anti-CD20 radioimmunotherapy (BEXXAR) yields a cold antibody antitumor response (cold protein effect) and a radiation response. Biologically effective contributions, including the cold protein effect, are included in an equivalent biological effect model that was fit to patient data. METHODS: Fifty-seven tumors in 19 patients were followed using 6 single proton emission computed tomography (SPECT)/CT studies, 3 each post tracer (5 mCi) and therapy (∼100 mCi) injections with tositumomab and (131)I-tositumomab. Both injections used identical antibody mass, a flood dose of 450 mg plus 35 mg of (131)I tagged antibody. The SPECT/CT data were used to calculate absorbed dose rate distributions and tumor and whole-body time-activity curves, yielding a space-time dependent absorbed dose rate description for each tumor. Tumor volume outlines on CT were used to derive the time dependence of tumor size for tracer and therapy time points. A combination of an equivalent biological effect model and an inactivated cell clearance model was used to fit absorbed dose sensitivity and cold effect sensitivity parameters to tumor shrinkage data, from which equivalent therapy values were calculated. RESULTS: Patient responses were categorized into three groups: standard radiation sensitivity with no cold effect (7 patients), standard radiation sensitivity with cold effect (11 patients), and high radiation sensitivity with cold effect (1 patient). CONCLUSION: Fit parameters can be used to categorize patient response, implying a potential predictive capability.


Assuntos
Linfoma não Hodgkin/radioterapia , Modelos Biológicos , Radioimunoterapia/métodos , Anticorpos Monoclonais/uso terapêutico , Humanos , Radioisótopos do Iodo/uso terapêutico , Linfoma não Hodgkin/patologia , Linfoma não Hodgkin/terapia , Falha de Tratamento , Carga Tumoral/efeitos da radiação
6.
J Nucl Med ; 51(7): 1155-62, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20554734

RESUMO

UNLABELLED: For optimal treatment planning in radionuclide therapy, robust tumor dose-response correlations must be established. Here, fully 3-dimensional (3D) dosimetry was performed coupling SPECT/CT at multiple time points with Monte Carlo-based voxel-by-voxel dosimetry to examine such correlations. METHODS: Twenty patients undergoing (131)I-tositumomab for the treatment of refractory B-cell lymphoma volunteered for the study. Sixty tumors were imaged. Activity quantification and dosimetry were performed using previously developed 3D algorithms for SPECT reconstruction and absorbed dose estimation. Tumors were outlined on CT at multiple time points to obtain absorbed dose distributions in the presence of tumor deformation and regression. Equivalent uniform dose (EUD) was calculated to assess the biologic effects of the nonuniform absorbed dose, including the cold antibody effect. Response for correlation analysis was determined on the basis of the percentage reduction in the product of the largest perpendicular tumor diameters on CT at 2 mo. Overall response classification (as complete response, partial response, stable disease, or progressive disease) used for prediction analysis was based on criteria that included findings on PET. RESULTS: Of the evaluated tumor-absorbed dose summary measures (mean absorbed dose, EUD, and other measures from dose-volume histogram analysis), a statistically significant correlation with response was seen only with EUD (r = 0.36 and P = 0.006 at the individual tumor level; r = 0.46 and P = 0.048 at the patient level). The median value of mean absorbed dose for stable disease, partial response, and complete response patients was 196, 346, and 342 cGy, respectively, whereas the median value of EUD for each of these categories was 170, 363, and 406 cGy, respectively. At a threshold of 200 cGy, both mean absorbed dose and EUD had a positive predictive value for responders (partial response + complete response) of 0.875 (14/16) and a negative predictive value of 1.0 (3/3). CONCLUSION: Improved dose-response correlations were demonstrated when EUD incorporating the cold antibody effect was used instead of the conventionally used mean tumor-absorbed dose. This work demonstrates the importance of 3D calculation and radiobiologic modeling when estimating absorbed dose for correlation with outcome.


Assuntos
Algoritmos , Anticorpos Monoclonais/uso terapêutico , Antineoplásicos/uso terapêutico , Neoplasias/radioterapia , Radioimunoterapia/métodos , Radiometria/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Proliferação de Células/efeitos dos fármacos , Relação Dose-Resposta à Radiação , Humanos , Modelos Biológicos , Método de Monte Carlo , Radiometria/estatística & dados numéricos , Tomografia Computadorizada de Emissão , Tomografia Computadorizada de Emissão de Fóton Único
7.
J Nucl Med ; 51(4): 654-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20237032

RESUMO

UNLABELLED: A 3-dimensional (3D) imaging-based patient-specific dosimetry methodology incorporating antitumor biologic effects using biologically effective dose (BED) and equivalent uniform dose (EUD) was developed in this study. The methodology was applied to the dosimetry analysis of 6 non-Hodgkin lymphoma patients with a total of 10 tumors. METHODS: Six registered SPECT/CT scans were obtained for each patient treated with (131)I-labeled antibody. Three scans were obtained after tracer administration and 3 after therapy administration. The SPECT/CT scans were used to generate 3D images of cumulated activity. The cumulated activity images and corresponding CT scans were used as input to Monte Carlo dose-rate calculations. The dose-rate distributions were integrated over time to obtain 3D absorbed dose distributions. The time-dependent 3D cumulative dose distributions were used to generate 3D BED distributions. Techniques to incorporate the effect of unlabeled antibody (cold protein) in the BED analysis were explored. Finally, BED distributions were used to estimate an EUD for each tumor volume. Model parameters were determined from optimal fits to tumor regression data. The efficiency of dose delivery to tumors--the ratio of EUD to cumulative dose--was extracted for each tumor and correlated with patient response parameters. RESULTS: The model developed in this study was validated for dosimetry of non-Hodgkin lymphoma patients treated with (131)I-labeled antibody. Correlations between therapy efficiency generated from the model and tumor response were observed using averaged model parameters. Model parameter determination favored a threshold for the cold effect and typical magnitude for tumor radiosensitivity parameters. CONCLUSION: The inclusion of radiobiologic effects in the dosimetry modeling of internal emitter therapy provides a powerful platform to investigate correlations of patient outcome with planned therapy.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Imageamento Tridimensional , Linfoma não Hodgkin/radioterapia , Medicina de Precisão , Radiometria/métodos , Humanos , Linfoma não Hodgkin/patologia , Linfoma não Hodgkin/terapia , Dosagem Radioterapêutica , Resultado do Tratamento , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...