1.
Enzyme Microb Technol ; 133: 109457, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31874687

RESUMO

Highly sensitive in situ-synthesized cadmium sulfide (CdS) nanowires (NWs) for the detection of chemiluminescence in immunoassays with a photoresist (PR) layer to stabilize the CdS NWs before and after coating with a parylene film were developed. The thickness of the PR layer was controlled by adjusting the viscosity of the PR solution used for spin-coating. PR2005 was the optimal PR for passivation of the NW surface. After the addition of a parylene coating on the CdS NWs, the photocurrent increased by as much as 50% over a broad range of light intensities, and the additional PR layer increased the photoresponse over the whole range of light intensities. When the photoresponses of the CdS NWs with and without the parylene film were compared after the addition of a PR layer, significant differences were observed in the photocurrent behavior after the incident light was turned off. For the CdS NWs with a parylene film and PR layer, the photocurrent reached the baseline within milliseconds of the incident light being turned off. However, the CdS NWs without a parylene film but with a PR layer required >60 s to reach the baseline level. This difference was due to the capacitance arising from the contact between the NWs. The in situ-synthesized CdS NW photosensor passivated by the parylene film and a PR layer was used in a chemiluminescence-based immunoassay. Finally, the detection of human immunodeficiency virus antibodies was demonstrated via a chemiluminescent enzyme-linked immunosorbent assay based on the CdS NW photosensor in comparison with the optical-density measurement for the chromogenic reaction of TMB(3,3',5,5'-Tetramethylbenzidine).


Assuntos
Compostos de Cádmio/química , Imunoensaio/instrumentação , Luminescência , Nanofios/química , Sulfetos/química , Polímeros/química , Xilenos/química
2.
Biosens Bioelectron ; 92: 221-228, 2017 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-28219030

RESUMO

The direct in situ synthesis of cadmium sulfide (CdS) nanowires (NWs) was presented by direct synthesis of CdS NWs on the gold surface of an interdigitated electrode (IDE). In this work, we investigated the effect of a strong oxidant on the surfaces of the CdS NWs using X-ray photoelectron spectroscopy, transmission electron microscopy, and time-of-flight secondary ion mass spectrometry. We also fabricated a parylene-C film as a surface passivation layer for in situ-synthesized CdS NW photosensors and investigated the influence of the parylene-C passivation layer on the photoresponse during the coating of parylene-C under vacuum using a quartz crystal microbalance and a photoanalyzer. Finally, we used the in situ-synthesized CdS NW photosensor with the parylene-C passivation layer to detect the chemiluminescence of horseradish peroxidase and luminol and applied it to medical detection of carcinoembryonic antigen.


Assuntos
Técnicas Biossensoriais/instrumentação , Compostos de Cádmio/química , Antígeno Carcinoembrionário/sangue , Medições Luminescentes/instrumentação , Nanofios/química , Polímeros/química , Sulfetos/química , Xilenos/química , Desenho de Equipamento , Peroxidase do Rábano Silvestre/química , Humanos , Imunoensaio/instrumentação , Substâncias Luminescentes/química , Luminol/química , Nanofios/ultraestrutura , Oxirredução
3.
Anal Chim Acta ; 927: 99-106, 2016 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-27237842

RESUMO

A hypersensitive CdS nanowire (NW) photosensor was fabricated by an in-situ synthesis process that involved the direct synthesis of CdS NWs on an interdigitated electrode (IDE). Analysis of the photoresponse properties showed that the newly synthesized photosensor had enhanced sensitivity and a highly reproducible photoresponse compared to photosensors prepared from CdS NW suspensions. The NW photosensor was applied to measure the chemiluminescence of luminol, and the sensitivity was compared to a commercial photosensing system. Finally, the feasibility of the CdS NW photosensor for the application to the medical diagnosis of the human hepatitis B surface antigen (hHBsAg) was demonstrated using a lateral-flow immunoassay with a chemiluminescent signal band.


Assuntos
Compostos de Cádmio/química , Imunoensaio/métodos , Luz , Luminol/química , Nanofios , Compostos de Selênio/química , Antígenos de Superfície da Hepatite B/análise , Limite de Detecção , Luminescência , Reprodutibilidade dos Testes