Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neurol Sci ; 33(3): 673-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22080394

RESUMO

Central pontine myelinolysis and extrapontine myelinolysis are rare demyelinating diseases of the central nervous system. These diseases are related frequently to rapid correction of hyponatremia. They have also been described in association with other underlying conditions such as alcoholism and malnutrition. In the present study, we report a case of central pontine and extrapontine myelinolysis with acute hepatic dysfunction. The patient had no apparent evidence of hyponatremia and no history of alcohol abuse. On admission, the patient was lethargic; dysphagia, dysarthria, and quadriplegia were noted. Laboratory examination showed significantly increased transaminase without hyponatremia. Magnetic resonance imaging revealed abnormal signal intensities in the pons and thalamus. Consciousness level and clinical symptoms improved gradually within a week. We suggest that acute hepatic dysfunction may play an important role in the development of central pontine myelinolysis and extrapontine myelinolysis.


Assuntos
Hepatopatias/complicações , Mielinólise Central da Ponte/etiologia , Ponte/patologia , Idoso , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Mielinólise Central da Ponte/patologia
2.
Chin Med J (Engl) ; 124(3): 380-4, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21362337

RESUMO

BACKGROUND: Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. METHODS: CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. RESULTS: CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. CONCLUSIONS: The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico , Colonografia Tomográfica Computadorizada/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...