Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthop Surg ; 15(2): 606-616, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36482875

RESUMO

OBJECTIVE: Adolescent idiopathic scoliosis (AIS) is a three-dimensional structural deformity of the spine caused by the disruption of the biomechanical balance of the spine. However, the current biomechanical modeling and analysis methods of scoliosis cannot really describe the real state of the spine. This study aims to propose a high-precision biomechanical modeling and analysis method that can reflect the spinal state under gravity and provide a theoretical basis for therapeutics. METHODS: Combining CT and X-ray images of AIS patients, this study constructed an adjusted three-dimensional model and FE model of the spine corresponding to the patient's gravity position, including vertebral bodies, intervertebral discs, ribs, costal cartilage, ligaments, and facet cartilage. Then, the displacement and stress of the spine under gravity were analyzed. RESULTS: A model of the T1-Sacrum with 1.7 million meshes was constructed. After adding the gravity condition, the maximum displacement point was at T1 of thoracic vertebra (20.4 mm). The analysis indicates that the stress on the lower surface of the vertebral body in thoracolumbar scoliosis tended to be locally concentrated, especially on the concave side of the primary curvature's vertebral body (the maximum stress on the lower surface of T9 is 32.33 MPa) and the convex side of the compensatory curvature's vertebral body (the maximum stress on the lower surface of L5 is 41.97 MPa). CONCLUSION: This study provides a high-precision modeling and analysis method for scoliosis with full consideration of gravity. The reliability of the method was verified based on patient data. This model can be used to analyze the biomechanical characteristics of patients in the treatment plan design stage.


Assuntos
Disco Intervertebral , Cifose , Escoliose , Adolescente , Humanos , Escoliose/diagnóstico por imagem , Análise de Elementos Finitos , Reprodutibilidade dos Testes , Vértebras Torácicas/diagnóstico por imagem , Fenômenos Biomecânicos
2.
Orthop Surg ; 14(11): 3061-3069, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36177845

RESUMO

OBJECTIVE: To investigate the hip joint forces, Von Mises stress, contact pressure and micro-motion of hip prosthesis for developmental dysplasia of the hip (DDH) patients under different hip joint centers using musculoskeletal (MSK) multi-body dynamics and finite element analysis. METHODS: Both MSK multi-body dynamics model and finite element (FE) model were based on CT data of a young female DDH patient with total hip replacement and were developed to study the biomechanics of the S-ROM hip prosthesis. The same offset of hip joint center along all six orientations compared with the standard position was set to predict its effects on both MSK multi-body dynamics and contact mechanics during one gait cycle. RESULTS: The hip joint forces in the entire walking gait cycle showed two peak values and clear differences between them under different hip joint centers. The hip joint force increased when the hip joint center moved posteriorly (2101 N) and laterally (1969 N) to the anatomical center (1848 N) at the first peak by 13.7% and 6.6%, respectively. The hip joint force increased sharply when the hip center deviated laterally (2115 N) and anteriorly (2407 N), respectively, from the standard position (1742 N) at the second peak. For the sleeve of the S-ROM prosthesis, the maximum Von Mises stress and contact pressure of the sleeve increased if the hip joint center deviated from the anatomical center posteriorly at the first peak. However, the Von Mises stresses and contact pressure increased at anterior and lateral orientations, compared to that of the standard position at the second peak. Small changes were observed for the maximum relative sliding distance along most of the orientations at both peaks except in the lateral and medial orientations, in which an increase of 8.6% and a decrease of 13.6% were observed, respectively. CONCLUSION: The hip joint center obviously influenced the hip joint forces, stress, contact pressure and micro-motion of the hip implant for this female patient.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Feminino , Articulação do Quadril/cirurgia , Análise de Elementos Finitos , Marcha , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...