Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microbiol Methods ; 123: 114-25, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26844886

RESUMO

Quantitative polymerase chain reaction (qPCR) has become a frequently used technique for quantifying enterococci in recreational surface waters, but there are several methodological options. Here we evaluated how three method permutations, type of mastermix, sample extract dilution and use of controls in results calculation, affect method reliability among multiple laboratories with respect to sample interference. Multiple samples from each of 22 sites representing an array of habitat types were analyzed using EPA Method 1611 and 1609 reagents with full strength and five-fold diluted extracts. The presence of interference was assessed three ways: using sample processing and PCR amplifications controls; consistency of results across extract dilutions; and relative recovery of target genes from spiked enterococci in water sample compared to control matrices with acceptable recovery defined as 50 to 200%. Method 1609, which is based on an environmental mastermix, was found to be superior to Method 1611, which is based on a universal mastermix. Method 1611 had over a 40% control assay failure rate with undiluted extracts and a 6% failure rate with diluted extracts. Method 1609 failed in only 11% and 3% of undiluted and diluted extracts analyses. Use of sample processing control assay results in the delta-delta Ct method for calculating relative target gene recoveries increased the number of acceptable recovery results. Delta-delta tended to bias recoveries from apparent partially inhibitory samples on the high side which could help in avoiding potential underestimates of enterococci--an important consideration in a public health context. Control assay and delta-delta recovery results were largely consistent across the range of habitats sampled, and among laboratories. The methodological option that best balanced acceptable estimated target gene recoveries with method sensitivity and avoidance of underestimated enterococci densities was Method 1609 without extract dilution and using the delta-delta calculation method. The applicability of this method can be extended by the analysis of diluted extracts to sites where interference is indicated but, particularly in these instances, should be confirmed by augmenting the control assays with analyses for target gene recoveries from spiked target organisms.


Assuntos
Enterococcus/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Microbiologia da Água , Enterococcus/genética , Laboratórios/normas , Reação em Cadeia da Polimerase em Tempo Real/normas , Estados Unidos
2.
Environ Sci Technol ; 46(2): 945-53, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22133009

RESUMO

The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized protocol requires information on the reproducibility and sources of variation associated with qPCR methodology across laboratories. This study examines interlaboratory variability in the measurement of enterococci and Bacteroidales concentrations from standardized, spiked, and environmental sources of DNA using the Entero1a and GenBac3 qPCR methods, respectively. Comparisons are based on data generated from eight different research facilities. Special attention was placed on the influence of the DNA isolation step and effect of simplex and multiplex amplification approaches on interlaboratory variability. Results suggest that a crude lysate is sufficient for DNA isolation unless environmental samples contain substances that can inhibit qPCR amplification. No appreciable difference was observed between simplex and multiplex amplification approaches. Overall, interlaboratory variability levels remained low (<10% coefficient of variation) regardless of qPCR protocol.


Assuntos
Bactérias/isolamento & purificação , DNA Bacteriano/classificação , DNA Bacteriano/isolamento & purificação , Fezes/microbiologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Microbiologia da Água , Monitoramento Ambiental/métodos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...