Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 485
Filtrar
1.
Indian J Ophthalmol ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38990629

RESUMO

PURPOSE: To assess the safety and efficacy of bent ab interno needle goniectomy (BANG) in moderate to severe primary open angle glaucoma (POAG) eyes undergoing phacoemulsification (phaco). DESIGN: Single-arm, prospective, interventional study. METHODS: POAG patients with medically uncontrolled intraocular pressure (IOP), >15 mmHg for moderate and >12 mmHg for severe POAG, with visually significant cataract were recruited. All patients underwent BANG using a 26-gauge needle to excise 30° of the trabecular meshwork, along with phaco. Primary outcome was IOP. Secondary outcomes were success rate, percentage reduction in IOP/antiglaucoma medications (AGMs), and intraoperative complications. Success at 12 months was defined as: criterion A: IOP <15 mmHg for moderate glaucoma or <12 mm Hg for severe glaucoma with or without AGMs OR criterion B reduction in number of AGMs by >1. RESULTS: Thirty-two eyes of 32 patients underwent BANG + phaco. Mean age of the participants was 62.7 ± 8.4 years and there were 25 males and seven females. At 12 months, a significant decrease was noted in both IOP (from 17.6 ± 3.6 to 12 ± 1.6 mmHg, 31.8%; P < 0.001) and AGMs (from 3.7 ± 0.9 to 2.8 ± 0.8, 24.3%; P < 0.001). Twenty percent or more reduction in IOP was achieved in 62.5% (20/32) of eyes. Overall success (meeting either of the criteria A or B) at 12 months was achieved in 87.5% eyes. Mild postoperative hyphema was noted in 10 (31.2%) eyes, and two eyes (6.2%) required additional filtration surgery at 7 months. CONCLUSION: A 30-degree BANG with phaco in patients of POAG appears to be a safe, effective and affordable MIGS for developing countries.

2.
J Occup Environ Hyg ; 21(7): 485-493, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38901026

RESUMO

This study compared the effectiveness of N95 FFRs in providing respiratory protection for healthcare staff in a residential aged care facility (RACF) and tertiary teaching hospital (TTH) who had previously passed their occupational respiratory protection program fit test. A total of 126 healthcare workers who were regularly using N95 FFRs and who had previously passed a fit test participated in this comparative study. In this study, participants were again fit tested with the PortaCount machine, and their self-assessed tolerability of wearing an N95 FFR was assessed using a standardized questionnaire. The main outcome measures included the pass rate of the fit test and the assessment of tolerability and comfort of the N95 FFR. Across all participants, the fit test pass rate was low (27%), indicating persistent gaps in respiratory protection programs for healthcare workers during the ongoing COVID-19 pandemic. Hospital workers were 3.7 times more likely to pass the test compared to their counterparts in RACFs (p < 0.001). It was also found that workers in RACFs reported higher levels of discomfort and overall dissatisfaction with N95 FFRs compared to hospital staff. These findings highlight the need for targeted interventions and improvements in respiratory protection practices beyond annual fit testing, particularly in RACFs, to ensure the safety of healthcare workers and the vulnerable population they serve.


Assuntos
COVID-19 , Pessoal de Saúde , Respiradores N95 , Exposição Ocupacional , Centros de Atenção Terciária , Humanos , COVID-19/prevenção & controle , Masculino , Feminino , Exposição Ocupacional/prevenção & controle , Adulto , Pessoa de Meia-Idade , SARS-CoV-2 , Instituição de Longa Permanência para Idosos , Sistemas Automatizados de Assistência Junto ao Leito
3.
Appl Opt ; 63(16): E10-E17, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38856587

RESUMO

The dynamic fluctuations in the atmospheric refractive index, commonly referred to as optical turbulence, cause phase distortions of the electromagnetic waves propagating through the atmosphere. The consequent scintillations have large implications for free-space optical communication, laser remote sensing, and directed energy applications. The refractive index structure parameter (C n2), quantifying the strength of these fluctuations, is usually estimated using high-frequency micrometeorological measurements, employing sonic anemometer-thermometers or scintillometers. Despite providing highly accurate information, these systems are immensely complex and costly, especially for frequent field applications and remote locations. In this study, we have developed an empirical multinomial model for estimating C n2 using three-year macrometeorological data and validated it against collocated and concurrent micrometeorological measurements, from a tropical semi-arid location. This simpler model would be handy for applications in remote locations having weather station measurements alone.

4.
Circ Arrhythm Electrophysiol ; : e012684, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38939983

RESUMO

BACKGROUND: Atrial fibrillation (AF) and ventricular fibrillation (VF) episodes exhibit varying durations, with some spontaneously ending quickly while others persist. A quantitative framework to explain episode durations remains elusive. We hypothesized that observable self-terminating AF and VF episode lengths, whereby durations are known, would conform with a power law based on the ratio of system size and correlation length ([Formula: see text]. METHODS: Using data from computer simulations (2-dimensional sheet and 3-dimensional left-atrial), human ischemic VF recordings (256-electrode sock, n=12 patients), and human AF recordings (64-electrode basket-catheter, n=9 patients; 16-electrode HD-grid catheter, n=42 patients), conformance with a power law was assessed using the Akaike information criterion, Bayesian information criterion, coefficient of determination (R2, significance=P<0.05) and maximum likelihood estimation. We analyzed fibrillatory episode durations and [Formula: see text], computed by taking the ratio between system size ([Formula: see text], chamber/simulation size) and correlation length ([Formula: see text], measured from pairwise correlation coefficients over electrode/node distance). RESULTS: In all computer models, the relationship between episode durations and [Formula: see text] was conformant with a power law (Aliev-Panfilov R2: 0.90, P<0.001; Courtemanche R2: 0.91, P<0.001; Luo-Rudy R2: 0.61, P<0.001). Observable clinical AF/VF durations were also conformant with a power law relationship (VF R2: 0.86, P<0.001; AF basket R2: 0.91, P<0.001; AF grid R2: 0.92, P<0.001). [Formula: see text] also differentiated between self-terminating and sustained episodes of AF and VF (P<0.001; all systems), as well as paroxysmal versus persistent AF (P<0.001). In comparison, other electrogram metrics showed no statistically significant differences (dominant frequency, Shannon Entropy, mean voltage, peak-peak voltage; P>0.05). CONCLUSIONS: Observable fibrillation episode durations are conformant with a power law based on system size and correlation length.

5.
Heliyon ; 10(11): e32206, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38933962

RESUMO

The study assesses the mechanical efficiency, long-lasting characteristics, microstructure, and sustainability of sustainable concrete (SC) samples through several optimization methods, emphasizing the significance of the 3Rs (recycle, reuse, reduce) approach in the construction sector. The study uses advanced techniques like the Taguchi method, grey relational analysis (GRA), analysis of variance (ANOVA), and signal-noise ratio (SNR) to optimize parameters affecting the performance of SC. In this study, the properties of SC are assessed by considering various parameters. These parameters include the use of 10 %, 20 %, and 30 % of ground granulated blast furnace slag (GGBFS) as a replacement for fly ash (FA). Additionally, six different binder contents ranging from 300 kg/m3 to 600 kg/m3 are examined. The study also investigates three different molarities of sodium hydroxide (NaOH) (8 M, 12 M, and 16 M), three different ratios of alkaline activators (AA) (1.5, 2.0, and 2.5), three different AA to-binder ratios (0.30, 0.35, and 0.40), and curing temperature (CT) of 30 °C, 60 °C, and 90 °C. The study includes fresh properties such as fresh density (FD) and slump, mechanical properties such as tensile strength (TS), flexural strength (FS), modulus of elasticity (MOE), and compressive strength (CS), and durability studies such as dry density (DD), impact strength, water absorption (WA), and sorptivity. The blended proportions were obtained using the Taguchi method. The study shows that GGBFS accelerates geopolymerization in FA-based concrete, reducing setting time and early-age CS. FA is crucial for setting time, workability, and CS enhancement. GGBFS increases the densities of fresh and hardened concrete, with a highly correlated increase, allowing accurate hardened density prediction with a coefficient of 0.9057. The CS of the cube SC surpassed 40 MPa, irrespective of variables such as the AA ratio, CT, and NaOH molarity. The trail mix with a binder concentration of 600 kg/m3, 30 % GGBFS content, 12 M NaOH molarity, 1.5 AA ratio, 0.35 AA to binder ratio, and 90 °C CT exhibited the greatest strength. Mixtures containing 10 % GGBFS can attain a CS above 30 MPa after 28 days, making them suitable for structural purposes. The T18 mix exhibited a compact Calcium (alumino) silicate hydrate (C-A-S-H) and N-A-S-H gel, whereas the T3 mix displayed a varied and permeable structure. The study used GRA, ANOVA, and SNR methods to analyze properties varying by six variables, finding GGBFS content as the most influencing parameter. The study found that the SC had a lower sustainability score than the OPC mix, but had better energy efficiency.

6.
IEEE Open J Eng Med Biol ; 5: 198-204, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606401

RESUMO

OBJECTIVE: This study addressed the problem of objectively detecting leaks in P2 respirators at point of use, an essential component for healthcare workers' protection. To achieve this, we explored the use of infra-red (IR) imaging combined with machine learning algorithms on the thermal gradient across the respirator during inhalation. RESULTS: The study achieved high accuracy in predicting pass or fail outcomes of quantitative fit tests for flat-fold P2 FFRs. The IR imaging methods surpassed the limitations of self fit-checking. CONCLUSIONS: The integration of machine learning and IR imaging on the respirator itself demonstrates promise as a more reliable alternative for ensuring the proper fit of P2 respirators. This innovative approach opens new avenues for technology application in occupational hygiene and emphasizes the need for further validation across diverse respirator styles. SIGNIFICANCE STATEMENT: Our novel approach leveraging infra-red imaging and machine learning to detect P2 respirator leaks represents a critical advancement in occupational safety and healthcare workers' protection.

7.
J Curr Glaucoma Pract ; 18(1): 23-27, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38585163

RESUMO

Aims and background: Delayed suprachoroidal hemorrhage (DSCH) is a vision-threatening complication of intraocular surgeries with a higher prevalence in postglaucoma filtering surgeries. Through these case series of trabeculectomy complicated with DSCH, we aim to emphasize that correction of hypotony (inciting factor) is fundamental for complete resolution and prevention of recurrence. Case description: All three glaucoma patients underwent trabeculectomy surgery followed by DSCH on postoperative day 1. Drainage of DSCH using a 23 gauge trocar cannula within 48 hours of onset was performed along with exploration for the cause of hypotony. All three patients had satisfactory visual and anatomical outcomes. Conclusion: Early drainage using 23 gauge trocar cannulas gives good results in DSCH. The cause of hypotony must simultaneously be corrected during the drainage of DSCH. Preventive measures against hypotony should be taken while doing glaucoma filtering surgery. Clinical significance: Surgical exploration for the cause of hypotony must simultaneously be performed during drainage of DSCH. Primary preventive measures against hypotony and bleeding during glaucoma filtering surgeries, like the use of releasable sutures, viscoelastic in the anterior chamber, and discontinuation of anticoagulants, can be done. Early drainage using trocar cannulas gives satisfactory results in DSCH postglaucoma surgeries. How to cite this article: Beri N, Verma S, Bukke AN, et al. Early Drainage of Suprachoroidal Hemorrhage Combined with Surgical Correction of Hypotony after Trabeculectomy. J Curr Glaucoma Pract 2024;18(1):23-27.

8.
J Cardiovasc Electrophysiol ; 35(6): 1229-1231, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38654418

RESUMO

BACKGROUND: Real-time signal processing has to date been difficult to implement in the clinical electrophysiology laboratory. To date, no open access software solutions are available in electrophysiology (EP) laboratories to facilitate real-time intraprocedural signal analysis. We aimed to develop an open access, scalable Python plug-in to allow real-time signal processing during human EP procedures. METHODS AND RESULTS: A Python-based plug in for the widely available EnsiteX mapping system was developed. This plug-in utilized the LiveSync feature of the system to allow real-time signal analysis. An open access library was developed to allow end-users to implement real-time signal analysis using this platform, implemented in the Python programming language https://github.com/anand9176/WaveWatch5000Public. CONCLUSION: We have developed and demonstrated the feasibility of a readily scalable and open-access Python-based plug in to an electroanatomic mapping system (EnSiteX) to allow real-time processing and display of electrogram (EGM) based information for the procedural electrophysiologist to view intraprocedurally in the electrophysiology laboratory. The availability, to the clinician, of traditional and novel EGM-based metrics at the time of intervention, such as atrial fibrillation ablation, allows for key mechanistic insights into critical unresolved questions regarding arrhythmia mechanism.


Assuntos
Potenciais de Ação , Técnicas Eletrofisiológicas Cardíacas , Processamento de Sinais Assistido por Computador , Humanos , Fatores de Tempo , Software , Valor Preditivo dos Testes , Frequência Cardíaca , Estudos de Viabilidade
9.
BMC Cancer ; 24(1): 308, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448839

RESUMO

BACKGROUND: Cancer incidence and mortality vary across the globe, with nearly two-thirds of cancer-related deaths occurring in low- and middle-income countries. The rural-urban disparity in socio-demographic, behavioural, and lifestyle-related factors, as well as in access to cancer care, is one of the contributing factors. Population-based cancer registries serve as a measure for understanding the burden of cancer. We aimed to evaluate the rural-urban disparity in cancer burden and care of patients registered by an Indian population-based cancer registry. METHODS: This study collected data from Varanasi, Uttar Pradesh, India, between 2017 and 2019. Sex and site-specific age-standardised rates for incidence and mortality per 100,000 population were calculated. Rural-urban disparities in cancer incidence and mortality were estimated through rate differences and standardised rate ratios (with 95% confidence intervals). Univariable and multivariable regressions were applied to determine any significant differences in socio-demographic and cancer-related variables according to place of residence (rural/urban). Crude and adjusted odds ratios with 95% confidence intervals were calculated. RESULTS: 6721 cancer patients were registered during the study duration. Urban patients were older and had better literacy and socioeconomic levels, while rural patients had higher odds of having unskilled or semi-skilled professions. Diagnostic and clinical confirmation for cancer was significantly higher in urban patients, while verbal autopsy-based confirmation was higher in rural patients. Rural patients were more likely to receive palliative or alternative systems of medicine, and urban patients had higher chances of treatment completion. Significantly higher incidence and mortality were observed for oral cancer among urban men and for cervical cancer among rural women. Despite the higher incidence of breast cancer in urban women, significantly higher mortality was observed in rural women. CONCLUSIONS: Low- and middle-income countries are facing dual challenges for cancer control and prevention. Their urban populations experience unhealthy lifestyles, while their rural populations lack healthcare accessibility. The distinctness in cancer burden and pattern calls for a re-evaluation of cancer control strategies that are tailor-made with an understanding of urban-rural disparities. Context-specific interventional programmes targeting risk-factor modifications, cancer awareness, early detection, and accessibility to diagnosis and care are essential.


Assuntos
Neoplasias da Mama , Neoplasias Bucais , Neoplasias do Colo do Útero , Masculino , Humanos , Feminino , População Rural , Sistema de Registros
10.
JACC Clin Electrophysiol ; 10(2): 306-315, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38206259

RESUMO

BACKGROUND: Conduction system pacing (CSP) faces challenges in achieving reliable and safe deployments. Complex interactions between tissue and lead tip can result in endocardial entanglement, a drill effect that prevents penetration. No verified ex vivo model exists to quantitatively assess this relationship. OBJECTIVES: The purpose of this study was to quantitatively characterize CSP lead tip to tissue responses for 4 commonly used leads. METHODS: CSP leads (from Medtronic, Biotronik, Boston Scientific, and Abbott) were examined for helix rotation efficiency in ex vivo ovine right ventricular septa. A custom jig was utilized for rotation measurements. Fifteen turns were executed, documenting tissue-interface changes every 90° using high-resolution photography. Response curves (input rotation vs helix rotation) were evaluated using piecewise linear regression, with a focus on output vs input response slopes and torque breakpoint events. RESULTS: We analyzed 3,840 quarter-turn CSP insertions with 4 different lead types. Helix rotations were consistently less than input: Abbott Tendril = 0.21:1, Medtronic 3830 = 0.21:1, Biotronik Solia = 0.47:1, and Boston Scientific Ingevity = 0.56:1. Torque breakpoint events were observed on average 7.22 times per insertion (95% CI: 6.08-8.35; P = NS) across all leads. In 57.8% of insertions (37 of 64), uncontrolled torque breakpoint events occurred, signaling unexpected excess helix rotations. CONCLUSIONS: Using a robust ex vivo model, we revealed a muted helix rotation response compared with input turns on the lead, and frequent torque change events during insertion. This is critical for CSP implanters, emphasizing the potential for unexpected torque breakpoint events, and suggesting the need for novel lead designs or deployment methods to enhance CSP efficiency and safety.


Assuntos
Sistema de Condução Cardíaco , Humanos , Animais , Ovinos , Torque , Sistema de Condução Cardíaco/fisiologia , Boston
12.
Artigo em Inglês | MEDLINE | ID: mdl-38083259

RESUMO

Atrial fibrillation (AF) strikingly possesses the ability to abruptly transition into more organized electrical activity and spontaneously terminate, even after persisting for long periods. Despite being central to the clinical behavior and treatment of AF, these phenomena remain incompletely understood. In this paper, we hypothesized that the spontaneous termination of AF may represent a type of percolation phase transition, which is more likely to occur when a domain spanning cluster of refractory sites in the atrium are connected (called a 'percolation cluster'). This was assessed in n=50 computational simulations of AF developed using the Aliev-Panfilov (APV) 2-dimensional cell model. In self-terminating simulations of AF, it was found that the average refractory cluster size, χ(p) (median: 647.7), and the largest refractory cluster size, M1 (median: 1702.3), abruptly increased just prior to AF spontaneously terminating, indicating the onset of the formation of a domain spanning percolation cluster. In contrast, simulations of sustained AF did not demonstrate an increase in χ(p) (median: 463.0) and M1 (median: 1448.2). Self-terminating AF simulations also demonstrated hallmark properties characteristic of a percolation phase transition, such as an abrupt increase in χ(p) at the critical occupation probability pc. The cluster size distribution was also shown to obey a power law for various occupation probabilities p, also indicative of a percolation phase transition. Collectively, these properties suggests that the spontaneous termination of AF could be a form of percolation phase transition, which could provide new insights for AF treatment.


Assuntos
Fibrilação Atrial , Humanos , Projetos Piloto , Átrios do Coração
13.
J Cancer Res Ther ; 19(5): 1324-1329, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37787302

RESUMO

Background: Urinary bladder cancer (UBC) is a disease quite common in developed countries; however, its incidence is increasing in developing countries as well. The diagnosis of UBC is generally based on a number of methods, of which urinary cytology is a very commonly used one. But it is not very reliable. Therefore many new markers and methods are being investigated to make non-invasive diagnosis of UBC easy and reliable. Objective: This study was carried out to find the usefulness of microRNA (miRNA)-10a as a diagnostic and prognostic marker in non-muscle-invasive urinary bladder carcinoma. Material and Method: Twenty patients with UBC were taken as cases with 20 controls. Urine cytological examination was done, as well as histopathological examination of tumor tissue of cases. Urinary miRNA-10a estimation of both the cases and controls were done. Result and Conclusion: It was found that miRNA-10a is significantly high in urine of patients with UBC. Its value also significantly correlated with the grade and stage of the tumor. Hence it can be concluded that urinary miRNA-10a is a potential candidate in the diagnosis and prognosis of UBC.


Assuntos
MicroRNAs , Neoplasias da Bexiga Urinária , Humanos , Antígenos de Neoplasias , Biomarcadores Tumorais/urina , MicroRNAs/genética , Prognóstico , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/genética , Neoplasias da Bexiga Urinária/patologia
14.
Trop Med Int Health ; 28(8): 629-640, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37430444

RESUMO

OBJECTIVES: To describe utilisation of verbal autopsy as one of the data collection approaches in cancer registration in an Indian setting. We aimed to estimate the proportion and epidemiological characteristics of malignancies identified by the Varanasi population-based cancer registry (PBCR) using verbal autopsy between 2017 and 2019 and to develop a thematic network for implementing verbal autopsy. METHODS: This was a cross-sectional mixed-methods study. Quantitative methods were applied to analyse information from PBCR proforma of the verbal autopsy-confirmed cancers; qualitative methods were applied to evaluate verbal autopsy conducted by field staff from key informants. In-depth interviews of field staff for the challenges and potential solutions during verbal autopsy were assessed. RESULTS: Of 6466 registered cancers, 1103 (17.1%) were verbal autopsy-confirmed cancers, which had no other source of information. The majority of verbal autopsy cases were from vulnerable populations who were aged >50 years (721, 65.4%), female (607, 55.1%), from rural backgrounds (853, 77.3%), illiterate or just able to read and write (636, 57.7%), and from lower and middle-income groups (823, 74.6%). Verbal autopsy helped provide information about symptoms and site of disease, diagnostic and treatment details, and disease status. Major challenges during verbal autopsy described by field staff were incomplete cancer treatment, destruction of medical records and non-cooperation by the community and lack of support from the local workforce as cancer is not notifiable. CONCLUSION: Verbal autopsy helped identify cancers that would have been missed during active case finding from available resources. The majority of verbal autopsy-confirmed patients belonged to vulnerable populations. Non-cooperation from community and local health systems was major challenge during verbal autopsy. Developing robust cancer awareness, patient navigation, and social support programmes will strengthen verbal autopsy. Integration of standardised and reproducible methods of verbal autopsy in cancer registry and digitalization of health information, especially in limited-resource settings with weak vital registration, will facilitate completeness in cancer registration.


Assuntos
Neoplasias , Humanos , Feminino , Causas de Morte , Autopsia/métodos , Estudos Transversais , Inquéritos e Questionários , Índia/epidemiologia , Neoplasias/epidemiologia , Sistema de Registros
15.
ACS Omega ; 8(23): 20404-20411, 2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37323413

RESUMO

Porous polymeric microspheres are an emerging class of materials, offering stimuli-responsive cargo uptake and release. Herein, we describe a new approach to fabricate porous microspheres based on temperature-induced droplet formation and light-induced polymerization. Microparticles were prepared by exploiting the partial miscibility of a thermotropic liquid crystal (LC) mixture composed of 4-cyano-4'-pentylbiphenyl (5CB, unreactive mesogens) with 2-methyl-1,4-phenylene bis4-[3-(acryloyloxy)propoxy] benzoate (RM257, reactive mesogens) in methanol (MeOH). Isotropic 5CB/RM257-rich droplets were generated by cooling below the binodal curve (20 °C), and the isotropic-to-nematic transition occurred after cooling below 0 °C. The resulting 5CB/RM257-rich droplets with radial configuration were subsequently polymerized under UV light, resulting in nematic microparticles. Upon heating the mixture, the 5CB mesogens underwent a nematic-isotropic transition and eventually became homogeneous with MeOH, while the polymerized RM257 preserved its radial configuration. Repeated cycles of cooling and heating resulted in swelling and shrinking of the porous microparticles. The use of a reversible materials templating approach to obtain porous microparticles provides new insights into binary liquid manipulation and potential for microparticle production.

16.
J Pediatr X ; 8: 100084, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37334030

RESUMO

Objective: To assess the association between the General Movement Assessment (GMA) findings, including Motor Optimality Scores-Revised (MOS-R) at 16 weeks, and neuromotor outcome assessed by the Amiel-Tison Neurological Assessment at 9 months of corrected age and the Developmental Assessment Scales for Indian Infants (DASII) at 1 year of corrected age in preterm ≤32 weeks. Study design: Serial GMA videos of infants born preterm ≤32 weeks were recorded on day 7, 35 weeks of postmenstrual age, 40 weeks of postmenstrual age, and 16 weeks of corrected age. The association between GMA findings, including MOS-R scores and GM trajectory between 35 to 40 weeks and the Amiel-Tison Neurological Assessment and DASII scores, was assessed by Spearman correlation, Fisher exact tests, and ordinal regression. Results: Moderate correlations were observed between MOS-R and the DASII motor DQ (Spearman r = 0.70, P < .001) and between MOS-R and DASII Mental DQ (r = 0.65, P < .001). The GMA trajectory at 35-40 weeks was associated with DASII motor DQ (Fisher exact, P = .002), and also with the Amiel-Tison Neurological Assessment at 9 months of corrected age (P < .01 by the Fisher exact test). On analysis by performing ordinal regression of predictive values of the general movements (GM) at 7 days of age, GM at 35 weeks, GM at 40 weeks, GM at 16 weeks, and MOS-R at 16 weeks, MOS-R alone was a statistically significant predictor of motor DQ at 1 year of age (OR -0.59; 95% CI -0.97 to -0.22; Wald statistics, P < .02). Conclusions: Consistent with findings in high-income countries, GMA including MOS-R scores performed in Indian infants born preterm during the neonatal period and early infancy is associated with neurodevelopmental outcomes in the first year of life. GMA can help initiate focused early intervention in low- and middle-income settings, where resources may be limited.

17.
Chaos ; 33(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37307158

RESUMO

Atrial and ventricular fibrillation (AF/VF) are characterized by the repetitive regeneration of topological defects known as phase singularities (PSs). The effect of PS interactions has not been previously studied in human AF and VF. We hypothesized that PS population size would influence the rate of PS formation and destruction in human AF and VF, due to increased inter-defect interaction. PS population statistics were studied in computational simulations (Aliev-Panfilov), human AF and human VF. The influence of inter-PS interactions was evaluated by comparison between directly modeled discrete-time Markov chain (DTMC) transition matrices of the PS population changes, and M/M/∞ birth-death transition matrices of PS dynamics, which assumes that PS formations and destructions are effectively statistically independent events. Across all systems examined, PS population changes differed from those expected with M/M/∞. In human AF and VF, the formation rates decreased slightly with PS population when modeled with the DTMC, compared with the static formation rate expected through M/M/∞, suggesting new formations were being inhibited. In human AF and VF, the destruction rates increased with PS population for both models, with the DTMC rate increase exceeding the M/M/∞ estimates, indicating that PS were being destroyed faster as the PS population grew. In human AF and VF, the change in PS formation and destruction rates as the population increased differed between the two models. This indicates that the presence of additional PS influenced the likelihood of new PS formation and destruction, consistent with the notion of self-inhibitory inter-PS interactions.


Assuntos
Fibrilação Atrial , Fibrilação Ventricular , Humanos , Átrios do Coração , Cadeias de Markov , Probabilidade
18.
J Occup Environ Hyg ; 20(7): 304-314, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37084394

RESUMO

Correctly fitting N95 filtering facepiece respirators (FFRs) have become increasingly important in health care throughout the COVID-19 pandemic. We evaluated the hypothesis that personalized 3D-printed frames could improve N95 FFRs quantitative fit test pass rates and test scores in health care workers (HCWs). HCWs were recruited at a tertiary hospital in Adelaide, Australia (ACTRN 12622000388718). A mobile iPhone camera + app was used to produce 3D scans of volunteers' faces, which were then imported into a software program to produce personalized virtual scaffolds suited to each user's face and their unique anatomical features. These virtual scaffolds were printed on a commercially available 3D printer, producing plastic (and then silicone-coated, biocompatible) frames that can be fitted inside existing hospital supply N95 FFR. The primary endpoint was improved pass rates on quantitative fit testing, comparing participants wearing an N95 FFR alone (control 1) with participants wearing the frame + N95 FFR (intervention 1). The secondary endpoint was the fit factor (FF) in these groups, and R-COMFI respirator comfort and tolerability survey scores. N = 66 HCWs were recruited. The use of intervention 1 increased overall fit test pass rates to 62/66 (93.8%), compared to 27/66 (40.9%) for controls. (OR for pFF pass 20.89 (95%CI: 6.77, 64.48, p < 0.001.) Average FF increased, with the use of intervention 1-179.0 (95%CI: 164.3,193.7), compared to 85.2 (95%CI: 70.4,100.0) with control 1. Pass rates and FF were improved with intervention 1 compared to control 1 for all stages of the fit-test: bending, talking, side-to-side, and up-down motion. (p < 0.001 all stages). Tolerability and comfort of the frame were evaluated with the validated R-COMFI respirator comfort score, showing improvement with the frame compared to N95 FFR alone (p = 0.006). Personalized 3D-printed face frames decrease leakage, improve fit testing pass rates and FF, and provide improved comfort compared to the N95 FFR alone. Personalized 3D-printed face frames represent a rapidly scalable new technology to decrease FFR leakage in HCW and potentially the wider population.


Assuntos
COVID-19 , Exposição Ocupacional , Dispositivos de Proteção Respiratória , Humanos , Respiradores N95 , Pandemias , Estudos Cross-Over , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , COVID-19/prevenção & controle , Desenho de Equipamento , Impressão Tridimensional
19.
Indian J Cancer ; 2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36861723

RESUMO

Background: The cancer registry provides reliable data from the population. In this article, we provide cancer burden and its patterns from the Varanasi district. Methods: The method adopted by the Varanasi cancer registry is community interaction along with regular visits to more than 60 sources to collect data on cancer patients. The cancer registry was established by the Tata Memorial Centre, Mumbai, in 2017 covering 4 million population (57% rural and 43% urban population). Results: The registry has recorded 1,907 incidence cases (1,058 male and 849 female). The age-adjusted incidence rate per 100,000 population in male and female of Varanasi district is 59.2 and 52.1, respectively. One in 15 male and one in 17 female are at risk of developing the disease. Mouth and tongue cancers are the predominant cancers in male, whereas breast, cervix uteri, and gallbladder are the leading cancer sites among the female. In female, cervix uteri cancer is significantly higher (double) in rural areas when compared with urban areas (rate ratio [RR] 0.5, 95% confidence interval [CI; 0.36, 0.72]), whereas in male, mouth cancer is higher in urban areas when compared with rural areas (RR 1.4, 95% CI [1.11, 1.72]). More than 50% of cancer cases in male are due to tobacco consumption. There may be underreporting of the cases. Conclusion: The results of the registry warrant policies and activities related to early detection services for the mouth, cervix uteri, and breast cancers. The Varanasi cancer registry is the foundation for cancer control and will play an important role in the evaluation of the interventions.

20.
Curr Opin Pulm Med ; 29(2): 76-82, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36630203

RESUMO

PURPOSE OF REVIEW: Exposure to asbestos can cause both benign and malignant, pulmonary and pleural diseases. In the current era of low asbestos exposure, it is critical to be aware of complications from asbestos exposure; as they often arise after decades of exposure, asbestos-related pulmonary complications include asbestosis, pleural plaques, diffuse pleural thickening, benign asbestos-related pleural effusions and malignant pleural mesothelioma. RECENT FINDINGS: Multiple recent studies are featured in this review, including a study evaluating imaging characteristics of asbestos with other fibrotic lung diseases, a study that quantified pleural plaques on computed tomography imaging and its impact on pulmonary function, a study that examined the risk of lung cancer with pleural plaques among two large cohorts and a review of nonasbestos causes of malignant mesothelioma. SUMMARY: Asbestos-related pulmonary and pleural diseases continue to cause significant morbidity and mortality. This review summarizes the current advances in this field and highlights areas that need additional research.


Assuntos
Amianto , Asbestose , Pneumopatias , Neoplasias Pulmonares , Mesotelioma Maligno , Mesotelioma , Doenças Pleurais , Derrame Pleural , Humanos , Mesotelioma/etiologia , Mesotelioma/patologia , Amianto/toxicidade , Doenças Pleurais/diagnóstico por imagem , Doenças Pleurais/etiologia , Pneumopatias/complicações , Asbestose/complicações , Asbestose/diagnóstico por imagem , Asbestose/patologia , Derrame Pleural/etiologia , Neoplasias Pulmonares/induzido quimicamente , Mesotelioma Maligno/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...