Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Vet Med Int ; 2022: 9112961, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36465855

RESUMO

Background: Glucometers or portable sensors are used to quickly measure blood glucose at low cost. They are used in veterinary practice and by guardians to monitor diseases that require, as in diabetes mellitus. However, not all commercially available glucometers (human and veterinary) are suitable for this purpose. Hypotheses/Objectives. The objective was to evaluate the analytical and clinical precision of three human-use portable glucometers. Animals. This study evaluated 115 samples in three glycemic ranges (hypoglycemia, normoglycemia, and hyperglycemia) from 82 dogs recruited from veterinary services. Methods: The portable glucometers are the FreeStyle Freedom Lite®, FreeStyle Optium Neo®, and On Call Plus® models. Glucometer results were compared with the enzymatic colorimetric glucose oxidase laboratory reference method. Using descriptive and comparative statistical analysis, there were correlations between these devices and the standard method, ISO 15197 : 2003 and ISO 15197 : 2013 standards, and error grid analysis. Results: Only the Freedom Lite® device observed a statistical difference when compared with the reference method. Despite the underestimated glucose concentrations assessed with humane devices, all three tested herein showed a positive coefficient. However, none of these achieved all ISO guidelines. Conclusion and Clinical Importance. Although there was wide use of portable humane devices for dog glucose measurements on routine, the results are generally inferior when compared to the reference method. The FreeStyle Optium Neo® glucometer obtained the best result and is therefore the best option among the glucometers evaluated; however, for the first attendance on veterinary routine, all three glucometers had a satisfactory glucose measurement until the reference method availability.

2.
Food Res Int ; 107: 314-324, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29580491

RESUMO

The present study demonstrates the need to conduct an integrative quality control of teas marketed as Plantago major. In the present study, quality control checks were performed through macroscopic, microscopic and chemical analyses of commercial brands. Leaves with parts not allowed for consumption were found in all brands. Six brands showed histological similarity <50% with the authentic P. major. Eight brands demonstrated low chemical similarity (40 to 60%), indicating that they do not have the same compounds from the authentic P. major. All commercial samples are contaminated with aflatoxins, indicative of fungicide contamination and consequent degradation of phenolic compounds and reduction of antioxidant activity from the commercial samples. The difference in the present study is the integrative application of methods for success in the quality control of P. major, which can be applied to other species. Thus, more rigorous inspection actions in the production of teas to guarantee the therapeutic benefit of these products.


Assuntos
Folhas de Planta/química , Plantago/química , Controle de Qualidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Chá/química , Fenóis/análise , Fenóis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA