Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Ergon ; 109: 103990, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36791557

RESUMO

BACKGROUND: Training clinicians on the use of hospital-based patient monitoring systems (PMS) is vital to mitigate the risk of use errors and of frustration using these devices, especially when used in ICU settings. PMS training is typically delivered through face-to-face training sessions in the hospital. However, it is not always feasible to deliver training in this format to all clinical staff given some constraints (e.g., availability of staff and trainers to attend in-person training sessions and the costs associated with face-to-face training). OBJECTIVE: The literature indicates that E-learning has the potential to mitigate barriers associated with time restrictions for trainers and trainees and evidence shows it to be more flexible, and convenient for learners in healthcare settings. This study aimed to develop and carry out a preliminary evaluation via a case study of an e-learning training platform designed for a novel neonatal sepsis risk monitor system (Digi-NewB). METHODS: A multi-modal qualitative research case study approach was used, including the analysis of three qualitative data sources: (i) audio/video recordings of simulation sessions in which participants were asked to operate the system as intended (e.g., update the clinical observations and monitor the sepsis risk), (ii) interviews with the simulation participants and an attending key opinion leader (KOL), who observed all simulation sessions, and (iii) post-simulation survey. RESULTS: After receiving ethical approval for the study, nine neonatal intensive care unit (NICU) nurses completed the online training and participated in the simulation and follow-up interview sessions. The KOL was also interviewed, and seven out of the nine NICU nurses answered the post-simulation survey. The video/audio analysis of the simulations revealed that participants were able to use and interpret the Digi-NewB interface. Interviews with simulation participants and the KOL, and feedback extracted from the survey, revealed that participants were overall satisfied with the training platform and perceived it as an efficient and effective method to deliver medical device training. CONCLUSIONS: This study developed an online training platform to train clinicians in the use of a critical care medical device and carried out a preliminary evaluation of the platform via a case study. The e-learning platform was designed to supplement and enhance other training approaches. Further research is required to evaluate the effectiveness of this approach.


Assuntos
Instrução por Computador , Sepse Neonatal , Recém-Nascido , Humanos , Aprendizagem , Inquéritos e Questionários , Unidades de Terapia Intensiva
2.
JMIR Hum Factors ; 8(2): e16491, 2021 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-34032574

RESUMO

BACKGROUND: Continuous monitoring of the vital signs of critical care patients is an essential component of critical care medicine. For this task, clinicians use a patient monitor (PM), which conveys patient vital sign data through a screen and an auditory alarm system. Some limitations with PMs have been identified in the literature, such as the need for visual contact with the PM screen, which could result in reduced focus on the patient in specific scenarios, and the amount of noise generated by the PM alarm system. With the advancement of material science and electronic technology, wearable devices have emerged as a potential solution for these problems. This review presents the findings of several studies that focused on the usability and human factors of wearable devices designed for use in critical care patient monitoring. OBJECTIVE: The aim of this study is to review the current state of the art in wearable devices intended for use by clinicians to monitor vital signs of critical care patients in hospital settings, with a focus on the usability and human factors of the devices. METHODS: A comprehensive literature search of relevant databases was conducted, and 20 studies were identified and critically reviewed by the authors. RESULTS: We identified 3 types of wearable devices: tactile, head-mounted, and smartwatch displays. In most cases, these devices were intended for use by anesthesiologists, but nurses and surgeons were also identified as potentially important users of wearable technology in critical care medicine. Although the studies investigating tactile displays revealed their potential to improve clinical monitoring, usability problems related to comfort need to be overcome before they can be considered suitable for use in clinical practice. Only a few studies investigated the usability and human factors of tactile displays by conducting user testing involving critical care professionals. The studies of head-mounted displays (HMDs) revealed that these devices could be useful in critical care medicine, particularly from an ergonomics point of view. By reducing the amount of time the user spends averting their gaze from the patient to a separate screen, HMDs enable clinicians to improve their patient focus and reduce the potential of repetitive strain injury. CONCLUSIONS: Researchers and designers of new wearable devices for use in critical care medicine should strive to achieve not only enhanced performance but also enhanced user experience for their users, especially in terms of comfort and ease of use. These aspects of wearable displays must be extensively tested with the intended end users in a setting that properly reflects the intended context of use before their adoption can be considered in clinical settings.

3.
JMIR Hum Factors ; 7(3): e15052, 2020 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-32618574

RESUMO

BACKGROUND: The patient monitor (PM) is one of the most commonly used medical devices in hospitals worldwide. PMs are used to monitor patients' vital signs in a wide variety of patient care settings, especially in critical care settings, such as intensive care units. An interesting observation is that the design of PMs has not significantly changed over the past 2 decades, with the layout and structure of PMs more or less unchanged, with incremental changes in design being made rather than transformational changes. Thus, we believe it well-timed to review the design of novel PM interfaces, with particular reference to usability and human factors. OBJECTIVE: This paper aims to review innovations in PM design proposed by researchers and explore how clinicians responded to these design changes. METHODS: A literature search of relevant databases, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, identified 16 related studies. A detailed description of the interface design and an analysis of each novel PM were carried out, including a detailed analysis of the structure of the different user interfaces, to inform future PM design. The test methodologies used to evaluate the different designs are also presented. RESULTS: Most of the studies included in this review identified some level of improvement in the clinician's performance when using a novel display in comparison with the traditional PM. For instance, from the 16 reviewed studies, 12 studies identified an improvement in the detection and response times, and 10 studies identified an improvement in the accuracy or treatment efficiency. This indicates that novel displays have the potential to improve the clinical performance of nurses and doctors. However, the outcomes of some of these studies are weakened because of methodological deficiencies. These deficiencies are discussed in detail in this study. CONCLUSIONS: More careful study design is warranted to investigate the user experience and usability of future novel PMs for real time vital sign monitoring, to establish whether or not they could be used successfully in critical care. A series of recommendations on how future novel PM designs and evaluations can be enhanced are provided.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...