1.
Rev Sci Instrum ; 92(3): 035106, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33819998

RESUMO

Diffusion dynamics of water and oil are observed in real-time using video images. Savitzky-Golay derivative filtering ensures accurate localization of the liquid front. System identification demonstrates that a fractional-order model with only two parameters may be used to describe the dynamics of the diffusion process. The method paves the way for video-based cellulose filter paper microfluidics and lateral flow assays, which are low cost and have broad diagnostic applications.

2.
J Pharm Anal ; 9(3): 209-216, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31297299

RESUMO

In this work, lemon and onion biomasses commonly found in street markets are for the first time used to develop a facile, fast and low-cost one-step microwave-assisted carbonization method for synthesis of highly fluorescent carbon dots (CDs). The structure and optical properties of CDs were investigated by TEM, XRD, XRF, UV-Vis, FTIR, and fluorescence spectroscopy. CDs displayed satisfactory optical proprieties, a high quantum yield of 23.6%, and excellent water solubility, and the particle size was 4.23-8.22 nm with an average diameter of 6.15 nm. An efficient fluorescent resonance energy transfer (FRET) between the CDs and riboflavin was achieved with CDs acting as donor and riboflavin as acceptor. A linear relationship between FRET and the riboflavin concentration from 0.10 to 3.0 µg/mL was observed, allowing the development of an accurate and fast analytical method to determine this vitamin in multivitamin/mineral supplements. Despite the potential interferences in these supplements, CDs were selective for riboflavin under optimized conditions. A paired t-test at a 95% confidence level indicated no statistically significant difference between the proposed and the reference methods. Recovery test presented values ranged from 96.0% to 101.4%. The limit of detection and relative standard deviation were estimated at 1.0 ng/mL and <2.6% (n = 3), respectively. CDs were successfully synthesized in a domestic microwave oven (1450 W, 6 min), presenting satisfactory parameters when compared with results of other studies reported in the literature, suggesting that the proposed method is a potentially useful method for the synthesis of CDs and determination of riboflavin.

3.
Talanta ; 178: 384-391, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136838

RESUMO

A lab-made magnetic-mechanical robotic (MMR) system coupled to a flow-batch analyzer (FBA) for magnetic nanoparticles solid phase extraction (MSPE) is presented. As an illustrative application, an NMR-FBA couple was connected to a graphite furnace atomic absorption spectrometer (GFAAS) for quantification of trace cadmium in edible oils. Factors affecting MSPE, such as the amount of adsorbent, the type, concentration and volume of the eluent and elution time were studied. Under the optimized experimental conditions, the interferents studied did not reveal a significant change in the analytical response, indicating that proposed method is selective. The sampling rate, characteristic mass, working linear range, limits of detection (LOD), and sensitivity were 10h-1, 0.18pg, 0.05-1.0µgkg-1, 0.006µgL-1, and 0.4197, respectively. An enrichment factor of 9 was achieved using a 2.5mL oil sample. In order to evaluate the accuracy, a certified reference material was analyzed by the proposed and a reference method. The values obtained were compared with the one provided from the manufacturer and no statistically significant differences were observed among three values at a confidence level of 95% using paired t-test. In addition, the precision intra-day and inter day of the proposed method and the robustness were assessed and again no statistically significant differences were observed at a confidence level of 95%. The use of a microcolumn to immobilize the MNPs is not needed with the proposed MMR-FBA-GFAAS system, thus avoiding the well-known problem of non-uniform packing of the MNPs presented in previous flow-based automatic methods. Despite a high organic load of edible oils, the method developed is simple, robust and presents satisfactory analytical features when compared with others that have been reported in the literature, suggesting that it is a potentially useful alternative to determine trace analytes in viscous matrices without external pretreatment.


Assuntos
Cádmio/análise , Grafite/química , Nanopartículas de Magnetita/química , Óleos/química , Robótica , Extração em Fase Sólida/instrumentação , Espectrofotometria Atômica/métodos , Óxido de Alumínio/química , Cádmio/química , Cádmio/isolamento & purificação , Contaminação de Alimentos/análise , Limite de Detecção , Naftóis/química , Dodecilsulfato de Sódio/química
4.
Talanta ; 88: 717-23, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-22265564

RESUMO

Both turbidimetric and photometric determinations of total tannins in samples of green and black tea, using a micro-flow-batch analyzer (µFBA) were studied. The miniaturized system was formed using photocurable urethane-acrylate resin and ultraviolet lithography technique. The turbidimetric method was based on the precipitation reaction of Cu (II) with tannins in acetate medium at a pH of 4.5. The photometric method was based on the complexation reaction of tannins with ferrous tartrate. The turbidimetric µFBA was able to test 200 samples per hour. The photometric µFBA allowed 300 analyses per hour, generating 136µL of residue per analysis. The paired t test, at a 95% confidence level, showed no statistically significant differences between results obtained by both methods and the reference method. The urethane-acrylate µFBA maintained satisfactory physical and chemical properties, and represents an improvement over conventional flow-batch analyzer.


Assuntos
Taninos/análise , Chá/química , Acetatos/química , Resinas Acrílicas/química , Automação Laboratorial , Cobre/química , Concentração de Íons de Hidrogênio , Nefelometria e Turbidimetria , Processos Fotoquímicos , Fotometria , Poliuretanos/química , Raios Ultravioleta
5.
Talanta ; 86: 208-13, 2011 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-22063532

RESUMO

This study introduces the first micro-flow-batch analyzer (µFBA). A simple, low-cost, deep urethane-acrylate photo-resist ultraviolet-lithographic technique was used in its development. Details of the microfabrication process are presented including; the use of two superimposed photo-masks to improve the micro-channel and stop chamber border definition, as well as integration of an LED/phototransistor photometric pair, while using an open nylon-thread (fishing line) micro-mixing system for solutions homogenization. The system was used for photometric determination of Fe(II) in oral solution iron supplements employing the well-known 1,10-phenanthroline method, with instantaneously prepared micro-chamber calibration solutions. All analytical processes were accomplished by simply changing the timing parameters in the control software. It must be emphasized here that there was no outside preparation of the standard calibration solutions; the mixing was all done in-chamber/in-line, with all solutions maintained flowing while being proportioned for the measurement processes. The µFBA results were acceptable when compared to the reference method, and comparable to normal flow-batch systems. It was possible both to project and build a low-cost probe with high sample throughput (about 120 h(-1)), low relative standard deviations (about 1.1%), and reduced reagent consumption (30 times less than the reference method). The µFBA system based on urethane-acrylate presented satisfactory physical and chemical properties while keeping the flexibility, versatility, robustness, and multi-task characteristics of normal flow-batch analyzers. The µFBA system contributes to the advance of micro-analytical instrumentation, while realizing the basic principles of "Green Chemistry".