Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Innovations (Phila) ; 17(2): 102-110, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35275496

RESUMO

Objective: Adverse events following left ventricular assist device (LVAD) implantation are more common in women than in men, but the impact of gender differences on right ventricular (RV) failure is not well defined. Therefore, we calculated RV strain before and after LVAD implantation in matched groups of men and women to determine if gender differences in RV failure after LVAD might account for the gender differences in overall outcomes. Methods: RV free wall longitudinal strain (FWS) and fractional area change were calculated preoperatively and 3 months postoperatively using speckle-tracking echocardiography analysis. A total of 172 patients (86 women, 86 men) were then propensity score matched (1:1) for comparison. Results: Although women had higher preoperative CHA2DS2-VASc scores and more frequent moderate mitral regurgitation than men (P = 0.018), the preoperative hemodynamic parameters were similar. Preoperative RV-FWS was -6.7% in women and -6.0% in men (P = 0.65). Postoperatively, women had more progression to severe tricuspid regurgitation (TR) than men (15% vs 7%, P = 0.06). At 3 months the RV-FWS was -7.7% in women and -7.0% in men (P = 0.59). Postoperative TR was moderate-severe in 20% of women and in 9% of men (P = 0.001). Women had a higher incidence of venous thromboembolism, cardiac arrhythmias, and bleeding compared with men. Women also had higher mortality rates at discharge and 30 days after surgery, but the survival rates at 5 years were similar. Conclusions: RV strain measurements track standard hemodynamic and echocardiographic parameters and confirm that gender differences in outcomes following LVAD implantation are not related to gender differences in RV failure rates.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Feminino , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pontuação de Propensão , Estudos Retrospectivos , Insuficiência da Valva Tricúspide/complicações , Disfunção Ventricular Direita/epidemiologia
2.
Anesthesiology ; 131(5): 1063-1076, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31490294

RESUMO

BACKGROUND: Nitrous oxide can induce neurotoxicity. The authors hypothesized that exposure to nitrous oxide impairs axonal regeneration and functional recovery after central nervous system injury. METHODS: The consequences of single and serial in vivo nitrous oxide exposures on axon regeneration in four experimental male rat models of nervous system injury were measured: in vitro axon regeneration in cell culture after in vivo nitrous oxide administration, in vivo axon regeneration after sharp spinal cord injury, in vivo axon regeneration after sharp optic nerve injury, and in vivo functional recovery after blunt contusion spinal cord injury. RESULTS: In vitro axon regeneration 48 h after a single in vivo 70% N2O exposure is less than half that in the absence of nitrous oxide (mean ± SD, 478 ± 275 um; n = 48) versus 210 ± 152 um (n = 48; P < 0.0001). A single exposure to 80% N2O inhibits the beneficial effects of folic acid on in vivo axonal regeneration after sharp spinal cord injury (13.4 ± 7.1% regenerating neurons [n = 12] vs. 0.6 ± 0.7% regenerating neurons [n = 4], P = 0.004). Serial 80% N2O administration reverses the benefit of folic acid on in vivo retinal ganglion cell axon regeneration after sharp optic nerve injury (1277 ± 180 regenerating retinal ganglion cells [n = 7] vs. 895 ± 164 regenerating retinal ganglion cells [n = 7], P = 0.005). Serial 80% N2O exposures reverses the benefit of folic acid on in vivo functional recovery after blunt spinal cord contusion (estimate for fixed effects ± standard error of the estimate: folic acid 5.60 ± 0.54 [n = 9] vs. folic acid + 80% N2O 5.19 ± 0.62 [n = 7], P < 0.0001). CONCLUSIONS: These data indicate that nitrous oxide can impair the ability of central nervous system neurons to regenerate axons after sharp and blunt trauma.


Assuntos
Anestésicos Inalatórios/efeitos adversos , Regeneração Nervosa/efeitos dos fármacos , Óxido Nitroso/efeitos adversos , Traumatismos do Sistema Nervoso/patologia , Anestésicos Inalatórios/administração & dosagem , Animais , Células Cultivadas , Masculino , Regeneração Nervosa/fisiologia , Óxido Nitroso/administração & dosagem , Ratos , Ratos Sprague-Dawley , Traumatismos do Sistema Nervoso/fisiopatologia
3.
Ann Thorac Surg ; 103(6): 1858-1865, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28017337

RESUMO

BACKGROUND: Controversy exists when performing surgical atrial fibrillation ablation whether there is an increase in postoperative complications using biatrial (BA) lesions compared with only left atrial (LA) lesions, and some studies indicate similar efficacy. This study compares the clinical outcomes of BA and LA ablation lesions in mitral valve surgery patients. METHODS: From 2004 through 2014, 2,137 patients had mitral valve surgery with or without other surgeries in a single center. Of those, 836 (39%) had preoperative atrial fibrillation, and of those, 724 (86%) underwent atrial fibrillation ablation surgery; 257 patients had BA lesion sets and 359 had LA lesion sets. Propensity score matching of BA and LA patients was performed. RESULTS: Baseline differences included more postoperative complications in the BA group, specifically, permanent pacemaker placement (13% versus 7%; p = 0.006). Freedom from atrial fibrillation off antiarrhythmic drugs (72% BA versus 75% LA; p = 0.50), postoperative ablation (7% BA versus 5% LA; p = 0.20), stroke (0.11 versus 0.11 per 10 person-years; p = 0.91), and survival were similar between the groups. After matching, patients in the LA group had a higher freedom from postoperative ablation (p = 0.015), but no difference in freedom from atrial fibrillation off antiarrhythmic drugs (79% BA versus 69% LA; p = 0.09), and no difference in permanent pacemaker placement (10% versus 12%; p = 0.57). CONCLUSIONS: Patients undergoing mitral surgery with LA or BA ablation had similar outcomes, survival, and complications. Limiting lesions to the LA is an effective alternative to BA ablation for patients undergoing ablation with concomitant mitral valve surgery.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Valva Mitral/cirurgia , Idoso , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ablação por Cateter/efeitos adversos , Feminino , Seguimentos , Doenças das Valvas Cardíacas/complicações , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Pontuação de Propensão , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
4.
Circ Cardiovasc Qual Outcomes ; 9(1): 48-54, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26646817

RESUMO

BACKGROUND: There is a reported association between high clinical volume and improved outcomes. Whether this relationship is true for outpatients with coronary artery disease (CAD), heart failure (HF), and atrial fibrillation (AF) remains unknown. METHODS AND RESULTS: Using the PINNACLE Registry (2009-2012), average monthly provider and practice volumes were calculated for CAD, HF, and AF. Adherence with 4 American Heart Association CAD, 2 HF, and 1 AF performance measure were assessed at the most recent encounter for each patient. Hierarchical logistic regression models were used to assess the relationship between provider and practice volume and performance on eligible quality measures. Data incorporated patients from 1094 providers at 71 practices (practice level analyses n=654 535; provider level analyses n=529 938). Median monthly provider volumes were 79 (interquartile range [IQR], 51-117) for CAD, 27 (16-45) for HF, and 37 (24-54) for AF. Median monthly practice volumes were 923 (IQR, 476-1455) for CAD, 311 (145-657) for HF, and 459 (185-720) for AF. Overall, 55% of patients met all CAD measures, 72% met all HF measures, and 58% met the AF measure. There was no definite relationship between practice volume and concordance for CAD, AF, or HF (P=0.56, 0.52, and 0.79, respectively). In contrast, higher provider volume was associated with increased concordance for CAD and AF performance measures (P<0.001 for both), but not for HF (P=0.36). CONCLUSIONS: In the PINNACLE registry, performance was modest and variable. Higher provider volume was positively associated with quality, whereas practice volume was not.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Cardiologia/normas , Doença da Artéria Coronariana/tratamento farmacológico , Fidelidade a Diretrizes , Insuficiência Cardíaca/tratamento farmacológico , Padrões de Prática Médica/estatística & dados numéricos , Carga de Trabalho , Idoso , Fibrilação Atrial/epidemiologia , Fármacos Cardiovasculares/uso terapêutico , Doença da Artéria Coronariana/epidemiologia , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Modelos Logísticos , Masculino , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde , Melhoria de Qualidade , Sistema de Registros , Estados Unidos/epidemiologia
5.
J Thorac Cardiovasc Surg ; 150(1): 118-24.e2, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25896462

RESUMO

OBJECTIVES: A hemiarch reconstruction, using deep hypothermic circulatory arrest, is the conventional approach for proximal aortic arch reconstruction, but it carries risks of neurologic events and coagulopathy. The addition of a hemiarch reconstruction to an aortic root replacement may prevent future aortic arch pathology. Outcomes of this approach at a tertiary care institution were examined to determine whether the addition of a hemiarch reconstruction to an aortic root replacement conferred any additional risk. METHODS: A total of 384 patients underwent an aortic root replacement between April 2004 and June 2012. Of them, 177 (46%) had hemiarch replacement. Propensity score matching yielded 133 pairs of patients receiving hemiarch and non-hemiarch. RESULTS: Sinus segment diameter was similar between groups; ascending aortic diameter was greater in the hemiarch group (median 50 vs 44 mm; P < .001). The hemiarch group had longer perfusion (median 186 vs 120.5 minutes; P < .001) and crossclamp times (median 140 vs 104 minutes; P < .001); median circulatory arrest was 13 minutes. There was no difference, hemiarch versus no hemiarch, in 30-day mortality (3.0% vs 1.5%; P = .41), stroke (2.3% vs 4.5%; P = .31), reoperation for bleeding (11% vs 10%; P = .84), or overall survival (5-year 88.0% [95% confidence interval, 81.9-94.0] vs 91.4% [95% confidence interval, 85.8-96.9], P = .24). CONCLUSIONS: In this series, aortic root replacement ± hemiarch reconstruction had low mortality. Addition of hemiarch replacement extended perfusion times but not at the expense of safety. Hemiarch reconstruction should be performed when the aortic root aneurysm extends into the distal ascending aorta.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Terapia Combinada , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...