Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Res ; 87(7): 1273, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32242143

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

2.
Pediatr Res ; 87(7): 1244-1250, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31935747

RESUMO

BACKGROUND: Tissue oximeters are not interchangeable. Two instruments with sensors dedicated to preterm infants-INVOS 5100C and Nonin SenSmart X-100-have not yet been compared. METHODS: By measuring cerebral oxygenation in ten preterm infants with spontaneous apneic episodes defined by pulse oximeter readings (SpO2) below 80%, as well as tissue oxygenation during vascular occlusion on the forearm of ten adults, simultaneously we compared performance in the hypoxic range. RESULTS: We found the mean conversion equations to be StO2,SenSmart X-100 = 0.34 × StO2,INVOS 5100C + 44.8% during apnea in infants and StO2,SenSmart X-100 = 0.59 × StO2,INVOS 5100C + 34.4% during vascular occlusion. The individual regressions displayed large and statistically significant variations in both infants and adults. In three infants the INVOS sensor showed very little reaction to decreases in SpO2. CONCLUSIONS: These findings confirm that different NIRS devices give very different estimates when the oxygenation is low. The large variation when compared to SpO2 suggest that the sensor placement is very important in preterm infants.


Assuntos
Apneia/fisiopatologia , Monitorização Fisiológica/instrumentação , Oximetria/instrumentação , Adulto , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Espectroscopia de Luz Próxima ao Infravermelho
3.
J Cereb Blood Flow Metab ; 40(10): 2055-2065, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31665953

RESUMO

Diffuse correlation spectroscopy (DCS) can non-invasively and continuously asses regional cerebral blood flow (rCBF) at the cot-side by measuring a blood flow index (BFI) in non-traditional units of cm2/s. We have validated DCS against positron emission tomography using 15O-labeled water (15O-water PET) in a piglet model allowing us to derive a conversion formula for BFI to rCBF in conventional units (ml/100g/min). Neonatal piglets were continuously monitored by the BabyLux device integrating DCS and time resolved near infrared spectroscopy (TRS) while acquiring 15O-water PET scans at baseline, after injection of acetazolamide and during induced hypoxic episodes. BFI by DCS was highly correlated with rCBF (R = 0.94, p < 0.001) by PET. A scaling factor of 0.89 (limits of agreement for individual measurement: 0.56, 1.39)×109× (ml/100g/min)/(cm2/s) was used to derive baseline rCBF from baseline BFI measurements of another group of piglets and of healthy newborn infants showing an agreement with expected values. These results pave the way towards non-invasive, cot-side absolute CBF measurements by DCS on neonates.


Assuntos
Circulação Cerebrovascular/fisiologia , Tomografia por Emissão de Pósitrons/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Acetazolamida/farmacologia , Animais , Animais Recém-Nascidos , Diuréticos/farmacologia , Humanos , Hipóxia/fisiopatologia , Processamento de Imagem Assistida por Computador , Recém-Nascido , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Suínos
4.
Pediatr Res ; 86(4): 515-521, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31234195

RESUMO

BACKGROUND: The BabyLux device is a prototype optical neuro-monitor of cerebral oxygenation and blood flow for neonatology integrating time-resolved reflectance spectroscopy and diffuse correlation spectroscopy. METHODS: Here we report the variability of six consecutive 30 s measurements performed in 27 healthy term infants at rest. Poor data quality excluded four infants. RESULTS: Mean cerebral oxygenation was 59.6 ± 8.0%, with intra-subject standard deviation of 3.4%, that is, coefficient of variation (CV) of 5.7%. The inter-subject CV was 13.5%. Mean blood flow index was 2.7 × 10-8 ± 1.56 × 10-8 (cm2/s), with intra-subject CV of 27% and inter-subject CV of 56%. The variability in blood flow index was not reduced by the use of individual measures of tissue scattering, nor accompanied by a parallel variability in cerebral oxygenation. CONCLUSION: The intra-subject variability for cerebral oxygenation variability was improved compared to spatially resolved spectroscopy devices, while for the blood flow index it was comparable to that of other modalities for estimating cerebral blood flow in newborn infants. Most importantly, the simultaneous measurement of oxygenation and flow allows for interpretation of the high inter-subject variability of cerebral blood flow as being due to error of measurement rather than to physiological instability.


Assuntos
Circulação Cerebrovascular , Neonatologia/instrumentação , Consumo de Oxigênio , Oxigênio/sangue , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Encéfalo/fisiologia , Desenho de Equipamento , Hemodinâmica , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Monitorização Fisiológica/instrumentação , Reprodutibilidade dos Testes
5.
Arch Dis Child Fetal Neonatal Ed ; 104(6): F648-F653, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31085677

RESUMO

OBJECTIVES: A new device that combines, for the first time, two photonic technologies (time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy) was provided and tested within the BabyLux project. Aim was to validate the expected changes in cerebral oxygenation and blood flow. METHODS: A pulse oximeter and the BabyLux device were held in place (right hand/wrist and frontoparietal region, respectively) for 10 min after birth in healthy term infants delivered by elective caesarean section. Pulse oximeter saturation (SpO2), cerebral tissue oxygen saturation (StO2) and blood flow index (BFI) were measured over time. Tissue oxygen extraction (TOE) and cerebral metabolic rate of oxygen index (CMRO2I) were calculated. RESULTS: Thirty infants were enrolled in two centres. After validity check of data, 23% of infants were excluded from TOE and CMRO2I calculation due to missing data. As expected, SpO2 (estimate 3.05 %/min; 95% CI 2.78 to 3.31 %/min) and StO2 (estimate 3.95 %/min; 95% CI 3.63 to 4.27 %/min) increased in the first 10 min after birth, whereas BFI (estimate -2.84×10-9 cm2/s/min; 95% CI -2.50×10-9 to -3.24×10-9 cm2/s/min) and TOE (estimate -0.78 %/min; 95% CI -1.12 to -0.45 %/min) decreased. Surprisingly, CMRO2I decreased (estimate -7.94×10-8/min; 95% CI -6.26×10-8 to -9.62×10-8/min). CONCLUSIONS: Brain oxygenation and BFI during transition were successfully and simultaneously obtained by the BabyLux device; no adverse effects were recorded, and the BabyLux device did not limit the standard care. The preliminary results from clinical application of the BabyLux device are encouraging in terms of safety and feasibility; they are consistent with previous reports on brain oxygenation during transition, although the interpretation of the decreasing CMRO2I remains open. TRIAL REGISTRATION NUMBER: NCT02815618.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Oxigênio/sangue , Análise Espectral/instrumentação , Encéfalo/metabolismo , Cesárea , Feminino , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Oximetria , Espectroscopia de Luz Próxima ao Infravermelho
6.
Adv Exp Med Biol ; 1072: 375-379, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30178374

RESUMO

Several cerebral oximeters based on near-infrared spectroscopy (NIRS) are commercially available that determine tissue oxygen saturation (StO2). One problem is an inconsistency of StO2 readings between different brands of instruments. Liquid blood phantoms mimicking optical properties of the neonatal head enable quantitative device comparisons. However, occasionally, the reduced scattering coefficient (µs') of these phantoms decreases over time. AIM: To investigate whether this decrease in µs' affects the validity of comparison of these devices. StO2 was measured by several NIRS oximeters simultaneously on a phantom, which exhibited a particularly strong decrease in µs'. We found that a decrease in µs' by ≤16% from baseline led to deviations in StO2 of ≤3%.


Assuntos
Oximetria/instrumentação , Imagens de Fantasmas , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Humanos , Técnicas In Vitro
7.
J Biomed Opt ; 22(2): 25001, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28152128

RESUMO

Tissue oxygenation estimated by near-infrared spectroscopy (NIRS) is a volume-weighted mean of the arterial and venous hemoglobin oxygenation. In vivo validation assumes a fixed arterial-to-venous volume-ratio (AV-ratio). Regulatory cerebro-vascular mechanisms may change the AV-ratio. We used hypotension to investigate the influence of blood volume distribution on cerebral NIRS in a newborn piglet model. Hypotension was induced gradually by inflating a balloon-catheter in the inferior vena cava and the regional tissue oxygenation from NIRS ( rStO 2 , NIRS ) was then compared to a reference ( rStO 2 , COX ) calculated from superior sagittal sinus and aortic blood sample co-oximetry with a fixed AV-ratio. Apparent changes in the AV-ratio and cerebral blood volume (CBV) were also calculated. The mean arterial blood pressure (MABP) range was 14 to 82 mmHg. PaCO 2 and SaO 2 were stable during measurements. rStO 2 , NIRS mirrored only 25% (95% Cl: 21% to 28%, p < 0.001 ) of changes in rStO 2 , COX . Calculated AV-ratio increased with decreasing MABP (slope: ? 0.007 · mmHg ? 1


Assuntos
Volume Sanguíneo , Circulação Cerebrovascular , Hipóxia Encefálica/diagnóstico por imagem , Oximetria , Espectroscopia de Luz Próxima ao Infravermelho , Humanos
8.
Neurophotonics ; 3(3): 031407, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27158632

RESUMO

Preterm birth constitutes a major cause of death before 5 years of age and it is a major cause of neurodevelopmental impairment across the world. Preterm infants are most unstable during the transition between fetal and newborn life during the first days of life and most brain damage occurs in this period. The brain of the preterm infant is accessible for tissue oximetry by near-infrared spectroscopy. Cerebral oximetry has the potential to improve the long-term outcome by helping to tailor the support of respiration and circulation to the individual infant's needs, but the evidence is still lacking. The goals for research include testing the benefit and harms of cerebral oximetry in large-scale randomized trials, improved definition of the hypoxic threshold, better understanding the effects of intensive care on cerebral oxygenation, as well as improved precision of oximeters and calibration among devices or standardization of values in the hypoxic range. These goals can be pursued in parallel.

9.
J Biol Chem ; 288(38): 27534-27544, 2013 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-23884410

RESUMO

The dopamine transporter (DAT) is responsible for sequestration of extracellular dopamine (DA). The psychostimulant amphetamine (AMPH) is a DAT substrate, which is actively transported into the nerve terminal, eliciting vesicular depletion and reversal of DA transport via DAT. Here, we investigate the role of the DAT C terminus in AMPH-evoked DA efflux using cell-permeant dominant-negative peptides. A peptide, which corresponded to the last 24 C-terminal residues of DAT (TAT-C24 DAT) and thereby contained the Ca(2+)-calmodulin-dependent protein kinase IIα (CaMKIIα) binding domain and the PSD-95/Discs-large/ZO-1 (PDZ)-binding sequence of DAT, was made membrane-permeable by fusing it to the cell membrane transduction domain of the HIV-1 Tat protein (TAT-C24WT). The ability of TAT-C24WT but not a scrambled peptide (TAT-C24Scr) to block the CaMKIIα-DAT interaction was supported by co-immunoprecipitation experiments in heterologous cells. In heterologous cells, we also found that TAT-C24WT, but not TAT-C24Scr, decreased AMPH-evoked 1-methyl-4-phenylpyridinium efflux. Moreover, chronoamperometric recordings in striatum revealed diminished AMPH-evoked DA efflux in mice preinjected with TAT-C24WT. Both in heterologous cells and in striatum, the peptide did not further inhibit efflux upon KN-93-mediated inhibition of CaMKIIα activity, consistent with a dominant-negative action preventing binding of CaMKIIα to the DAT C terminus. This was further supported by the ability of a peptide with perturbed PDZ-binding sequence, but preserved CaMKIIα binding (TAT-C24AAA), to diminish AMPH-evoked DA efflux in vivo to the same extent as TAT-C24WT. Finally, AMPH-induced locomotor hyperactivity was attenuated following systemic administration of TAT-C24WT but not TAT-C24Scr. Summarized, our findings substantiate that DAT C-terminal protein-protein interactions are critical for AMPH-evoked DA efflux and suggest that it may be possible to target protein-protein interactions to modulate transporter function and interfere with psychostimulant effects.


Assuntos
Anfetamina/farmacologia , Peptídeos Penetradores de Células/farmacologia , Estimulantes do Sistema Nervoso Central/farmacologia , Corpo Estriado/metabolismo , Proteínas da Membrana Plasmática de Transporte de Dopamina/farmacologia , Dopamina/metabolismo , Anfetamina/efeitos adversos , Animais , Benzilaminas/farmacologia , Peptídeos Penetradores de Células/metabolismo , Estimulantes do Sistema Nervoso Central/efeitos adversos , Proteínas da Membrana Plasmática de Transporte de Dopamina/farmacocinética , Humanos , Masculino , Camundongos , Atividade Motora/efeitos dos fármacos , Domínios PDZ , Proteína Quinase C-alfa/antagonistas & inibidores , Proteína Quinase C-alfa/metabolismo , Inibidores de Proteínas Quinases/farmacologia , Sulfonamidas/farmacologia
10.
Nat Commun ; 4: 1580, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23481388

RESUMO

The dopamine transporter mediates reuptake of dopamine from the synaptic cleft. The cellular mechanisms controlling dopamine transporter levels in striatal nerve terminals remain poorly understood. The dopamine transporters contain a C-terminal PDZ (PSD-95/Discs-large/ZO-1) domain-binding sequence believed to bind synaptic scaffolding proteins, but its functional significance is uncertain. Here we demonstrate that two different dopamine transporter knock-in mice with disrupted PDZ-binding motifs (dopamine transporter-AAA and dopamine transporter+Ala) are characterized by dramatic loss of dopamine transporter expression in the striatum, causing hyperlocomotion and attenuated response to amphetamine. In cultured dopaminergic neurons and striatal slices from dopamine transporter-AAA mice, we find markedly reduced dopamine transporter surface levels and evidence for enhanced constitutive internalization. In dopamine transporter-AAA neurons, but not in wild-type neurons, surface levels are rescued in part by expression of a dominant-negative dynamin mutation (K44A). Our findings suggest that PDZ-domain interactions are critical for synaptic distribution of dopamine transporter in vivo and thereby for proper maintenance of dopamine homoeostasis.


Assuntos
Proteínas da Membrana Plasmática de Transporte de Dopamina/química , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Neostriado/metabolismo , Domínios PDZ , Sequência de Aminoácidos , Anfetamina/farmacologia , Animais , Comportamento Animal/efeitos dos fármacos , Sítios de Ligação , Transporte Biológico/efeitos dos fármacos , Proteínas de Transporte/metabolismo , Proteínas de Ciclo Celular , Dopamina/metabolismo , Neurônios Dopaminérgicos/efeitos dos fármacos , Neurônios Dopaminérgicos/metabolismo , Endocitose/efeitos dos fármacos , Retículo Endoplasmático/efeitos dos fármacos , Retículo Endoplasmático/metabolismo , Imuno-Histoquímica , Locomoção/efeitos dos fármacos , Camundongos , Camundongos Knockout , Mutação/genética , Neostriado/efeitos dos fármacos , Proteínas Nucleares/metabolismo , Fenótipo , Terminações Pré-Sinápticas/efeitos dos fármacos , Terminações Pré-Sinápticas/metabolismo , Ligação Proteica/efeitos dos fármacos , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...