Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 111(3): 186-94, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24210732

RESUMO

STATEMENT OF PROBLEM: In the past 5 years, the use of intraoral digitizers has increased. However, data are lacking on the accuracy of scanning implant restorative platforms for prosthodontics with intraoral digitizers. PURPOSE: The purpose of this clinical pilot study was to assess the applicability and accuracy of intraoral scans by using abutments designed for scanning (scan abutments) in edentulous mandibles. MATERIAL AND METHODS: Twenty-five participants with complete mandibular overdentures retained by 2 implants and frameworks were included in this study. Scan abutments were placed on the implants intraorally and scanned with the iTero intraoral scanner. Also, scan abutments were placed on the implant analogs of the definitive casts and scanned with an extraoral laboratory scanner (Lava Scan ST scanner). Two 3-dimensional computer-aided design models of the scan abutments with predetermined center lines were subsequently imported and registered, together with each of the scanned equivalents. The distance between the centers of the top of the scan abutments and the angulations between the scan abutments was assessed. These values were compared with the measurements made on the 3-dimensional scans of the definitive casts, which were the participants' original definitive casts used for fabrication of soldered bars. The threshold for distance error was established to be 100 µm. RESULTS: Four of the 25 intraoral scans were not suitable for research because the intraoral scanner was not able to stitch the separate scans together. Five of the 21 suitable scans demonstrated an interimplant distance error >100 µm. Three of the 25 intraoral scans showed interimplant angulation errors >0.4 degrees. Only 1 scan showed both an acceptable interimplant distance (<100 µm) and an acceptable angulation error (<0.4 degrees). CONCLUSIONS: Based on the intraoral scans obtained in this study, distance and angulation errors were too large to fabricate well-fitting frameworks on implants in edentulous mandibles. The main reason for the unreliable scans seemed to be the lack of anatomic landmarks for scanning.


Assuntos
Implantes Dentários , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Arcada Edêntula/patologia , Mandíbula/patologia , Desenho Assistido por Computador , Dente Suporte , Prótese Total Inferior , Revestimento de Dentadura , Precisão da Medição Dimensional , Humanos , Modelos Dentários , Projetos Piloto , Propriedades de Superfície
2.
PLoS One ; 7(8): e43312, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22937030

RESUMO

UNLABELLED: Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. MATERIALS AND METHODS: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three intra-oral scanners: the CEREC (Sirona), the iTero (Cadent) and the Lava COS (3M). In software the digital files were imported and the distance between the centres of the cylinders and the angulation between the cylinders was assessed. These values were compared to the measurements made on a high accuracy 3D scan of the master model. RESULTS: The distance errors were the smallest and most consistent for the Lava COS. The distance errors for the Cerec were the largest and least consistent. All the angulation errors were small. CONCLUSIONS: The Lava COS in combination with a high accuracy scanning protocol resulted in the smallest and most consistent errors of all three scanners tested when considering mean distance errors in full arch impressions both in absolute values and in consistency for both measured distances. For the mean angulation errors, the Lava COS had the smallest errors between cylinders 1-2 and the largest errors between cylinders 1-3, although the absolute difference with the smallest mean value (iTero) was very small (0,0529°). An expected increase in distance and/or angular errors over the length of the arch due to an accumulation of registration errors of the patched 3D surfaces could be observed in this study design, but the effects were statistically not significant. CLINICAL RELEVANCE: For making impressions of implant cases for digital workflows, the most accurate scanner with the scanning protocol that will ensure the most accurate digital impression should be used. In our study model that was the Lava COS with the high accuracy scanning protocol.


Assuntos
Técnica de Moldagem Odontológica/instrumentação , Materiais para Moldagem Odontológica , Humanos , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...