Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thorac Dis ; 10(Suppl 13): S1438-S1446, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29951295

RESUMO

In the last years, a great interest has arisen on immunotherapy for the treatment of advanced non-small cell lung cancer (NSCLC). Check-point inhibitor drugs are now considered clinical practice standard in different settings and their use is expected to increase significantly in the near future. As treatment options for lung cancer advance and vary, the different patterns of radiological response increase in number and heterogeneity. To correctly evaluate the radiological findings after and during these treatments is of paramount importance, both in the clinical and sperimental setting. In consideration of their peculiar mechanism, immunotherapies can determine unusual response patterns on imaging, that cannot be correctly evaluated with the traditional response criteria such as World Health Organization (WHO) and Response Evaluation Criteria in Solid Tumours (RECIST). Therefore, during these years, several response criteria [immune-related response criteria (irRC), irRECIST and iRECIST] were proposed and applied in clinical trials on immunotherapies. The aim of this review is to describe the radiological findings after immunotherapy, to critically discuss the different response criteria and the imaging of immune-related adverse events.

2.
Oncol Lett ; 14(2): 1602-1608, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28789385

RESUMO

The identification of cystic lesions within the retroperitoneal space is a rare event that poses clinicians the challenge of a difficult diagnosis and disease management. Retroperitoneal cystic lesions account for a group of lesions that range from common benign lesions (e.g., lymphoceles developing as a surgical complication) to rare aggressive malignant neoplasms. Currently, in the majority of cases, image-guided procedures allow for a pathological diagnosis to be achieved in these challenging lesions, thus offering the chance of an appropriate treatment; however, the overall clinical assessment of retroperitoneal cysts is highly demanding. The present study reports the management of a representative clinical case, presenting with a voluminous cystic mass able to dislocate cave vein, whose diagnosis was preceded by a deep vein thrombosis. Computed tomography-scan and ultrasound guided percutaneous drainage were performed to achieve the diagnosis. Following the discussion of the current case report, a review of the pathological and radiological characteristics of retroperitoneal cystic lesions is presented.

3.
Cardiovasc Intervent Radiol ; 40(6): 930-936, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28127631

RESUMO

PURPOSE: To prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook® Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle. MATERIALS AND METHODS: Study was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration. RESULTS: The technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/µl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively). CONCLUSIONS: Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.


Assuntos
Desenho de Equipamento , Neoplasias Pulmonares/patologia , Idoso , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Estudos de Viabilidade , Feminino , Humanos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
4.
J Belg Soc Radiol ; 101(1): 3, 2017 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-30038995
5.
Clin Case Rep ; 3(11): 960-1, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26576282

RESUMO

While acute arterial occlusion causes life-threatening ischemia and organ damage requiring urgent revascularization, the incidental identification of arterial occlusions in asymptomatic patients represents a therapeutic dilemma in clinicians. Does chronic asymptomatic artery occlusion require specific treatment?

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...