Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Glob Heart ; 17(1): 15, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35342698

RESUMO

Background: The alternative device to close perimembranous ventricular septal defect (pmVSD) has been searched for better result, less complications and applicable for infants. However, the ideal device is still unavailable. We aimed to evaluate the effectiveness and outcome of transcatheter pmVSD closure using the KONAR-multi functional occluder (MFO). Methods: Clinical, procedural, follow-up data of pmVSD patients with symptom of heart failure or evidence of significant left to right shunt, growth failure, recurrent respiratory tract infection, and history of endocarditis who underwent transcatheter closure using the MFO were prospectively evaluated. Results: Between January 2016 and December 2017, there were complete records of 132 pmVSD children closed using MFO from eleven centers in Indonesia. The median of age was 4.5 (0.3-17.4) years; weight 14.8 (3.5-57) kg, defect size at the smallest part 3.4 (1.0-8.1) mm, flow ratio 1.6 (1.3-4.9), mean pulmonary artery pressure 18 (7-79) mmHg, fluoroscopy time 18 (3.8-91) and procedural time 75 (26-290) minutes. A retrograde approach was done in 41 (31%) patients. Procedures succeeded in first attempt in 126 (95.4%), failed in three and migration in three patients. Six of eight infants with congestive heart failure were closed successfully. Of 126 patients with successful VSD closure, 12 months follow-up were completed in all patients. The rate of complete occlusion at 1 month, 3 months, 6 months and 12 months after intervention were 95.2%, 97.6%, 99.2%, and 99.2%, respectively. New-onset aortic regurgitation and moderate tricuspid regurgitation developed only in five and three patients. Neither complete atrioventricular block, nor other complications occurred. Conclusion: Transcatheter closure of pmVSD using the MFO is safe, effective, and feasible in infants and children.


Assuntos
Insuficiência Cardíaca , Comunicação Interventricular , Dispositivo para Oclusão Septal , Adolescente , Cateterismo Cardíaco , Criança , Pré-Escolar , Comunicação Interventricular/epidemiologia , Comunicação Interventricular/cirurgia , Humanos , Indonésia/epidemiologia , Lactente , Resultado do Tratamento
2.
Acta Med Indones ; 45(4): 295-301, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24448334

RESUMO

AIM: to assess for a correlation between T2*CMR with LV function and mass in thalassemic patients with iron overload. METHODS: a cross-sectional study on thalassemic patients was conducted between July and September 2010 at Cipto Mangunkusumo and Premier Hospitals, Jakarta, Indonesia. Clinical examinations, review of medical charts, electrocardiography, echocardiography, and T2*CMR were performed. Cardiac siderosis was measured by T2*CMR conduction time. Left ventricle diastolic and systolic functions, as well as LV mass index were measured using echocardiography. Correlations between T2*CMR and echocardiography findings, as well as serum ferritin were determined using Pearson's and Spearman's tests. RESULTS: thirty patients aged 13-41 years were enrolled, of whom two-thirds had -thalassemia major and one-third had HbE/-thalassemia. Diastolic dysfunction was identified in 8 patients, whereas systolic function was normal in all patients. Increased LV mass index was found in 3 patients. T2*CMR conduction times ranged from 8.98 to 55.04 ms and a value below 20 ms was demonstrated in 14 patients. There was a statistically significant moderate positive correlation of T2*CMR conduction time with E/A ratio (r = 0.471, P = 0.009), but no correlation was found with LV mass index (r=0.097, P=0.608). A moderate negative correlation was found between T2*CMR and serum ferritin (r = -0.514, P = 0.004), while a moderate negative correlation was found between serum ferritin and E/A ratio (r = -0.425, P = 0.019). CONCLUSION: T2*CMR myocardial conduction time has a moderate positive correlation with diastolic function, moderate negative correlation with serum ferritin, but not with LV mass index and systolic function.


Assuntos
Sobrecarga de Ferro , Imageamento por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda , Talassemia beta , Adolescente , Adulto , Estudos Transversais , Ecocardiografia/métodos , Eletrocardiografia/métodos , Feminino , Ferritinas/sangue , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Indonésia , Sobrecarga de Ferro/etiologia , Sobrecarga de Ferro/fisiopatologia , Masculino , Estatística como Assunto , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Talassemia beta/sangue , Talassemia beta/complicações , Talassemia beta/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...