Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 15(16)2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-36013625

RESUMO

The paper's aim is the assessment of corrosion behaviour of a CrNx-coated 310 H stainless steel under simulated supercritical water conditions (550 °C and 25 MPa) for up to 2160 h. The CrNx coating was obtained by the thermionic vacuum arc (TVA) method. The oxides grown on this coating were characterized using metallographic and gravimetric analysis, SEM with EDS, and grazing incidence X-ray diffraction (GIXRD). A diffusion mechanism drives oxidation kinetics because it follows a parabolic law. By XRD analysis, the presence of Cr2O3 and Fe3O4 on the surface of the autoclaved CrNx-coated 310 H samples were highlighted. Corrosion susceptibility assessment was performed by electrochemical impedance spectroscopy (EIS) and linear potentiodynamic polarization. EIS impedance spectra show the presence of two capacitive semicircles in the Nyquist diagram, highlighting both the presence of the CrNx coating and the oxide film formed during autoclaving on the 310 H stainless steel. Very low corrosion rates, with values up to 11 nm × year-1, obtained in the case of autoclaved for 2160 h, CrNx-coated samples indicated that the oxides formed on these samples are protective and provide better corrosion resistance. The determination of micro hardness Vickers completed the above investigation.

2.
Anal Bioanal Chem ; 412(17): 4135-4141, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32296903

RESUMO

Nanolayer and nanolayer by nanolayer deposition of nanofilms of Ag and C using cold plasma in sequences (Ag, Ag-C, Ag-Ag-C), on porous paper, were used to design three disposable stochastic sensors for the assay of amyloid polypeptide from whole blood. The nanofilms were modified with α-cyclodextrin. The test developed using the nanofilm-based disposable stochastic sensors is used for early detection of diabetes. The wider linear concentration range (1.00 × 10-6-1.00 ng mL-1) and the lower limit of quantification (1.00 × 10-6ng mL-1) were obtained using the disposable stochastic sensors based on Ag-C and Ag-Ag-C, while the highest sensitivity (3.19 × 104 s-1/µg mL-1) was recorded using the disposable stochastic sensor based on Ag-Ag-C. The screening methods were fully validated using whole blood samples from confirmed patients, when the recovery of the islet amyloid polypeptide was higher than 98.00%. Graphical abstract.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Técnicas Eletroquímicas/instrumentação , Polipeptídeo Amiloide das Ilhotas Pancreáticas/sangue , Nanoestruturas/química , Técnicas Eletroquímicas/economia , Desenho de Equipamento , Humanos , Limite de Detecção , Papel , Gases em Plasma/química , Porosidade , Prata/química , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...