1.
Eur J Cardiothorac Surg ; 28(1): 174-5, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15982602

RESUMO

Functional separation of the lungs may be accomplished by several methods. Patient with restricted mouth opening has limited options for one-lung ventilation. We report the use of wire-guided endobronchial blockade, a new tool for achieving one-lung ventilation in a patient with restricted mouth opening requiring nasotracheal, fiberoptic intubation for esophagectomy and reconstruction with gastric tube substitution.


Assuntos
Esofagectomia/métodos , Respiração Artificial/instrumentação , Idoso , Humanos , Intubação Intratraqueal/métodos , Masculino , Boca , Cavidade Nasal