Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Infect Control ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38825239

RESUMO

We report a cluster of 9 isolates of Parengyodontium album recovered from 4 patients who had surgical tissue specimens processed after dilution with a multiuse diluent saline solution. P album was also identified from a nonclinical sample on agar prepared with the same lot number of saline solution. Our epidemiological investigation revealed this to represent a pseudo-outbreak related to contaminated saline used to process specimens in the microbiology laboratory.

2.
Hosp Top ; 100(2): 69-76, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34470597

RESUMO

The 2019 SARS-CoV2 virus presented a capacity demand scenario for Yale New Haven Hospital. The response was created with a focus on clinical needs, but was also driven by the unique characteristics of the buildings within our institution. These physical characteristics were considered in the response as a safety measure as little was known about the transmissibility risk in the acute hospital setting of SARS-CoV2 at the time of response. The lessons learned in capacity expansion to meet the potentially catastrophic demand for acute care services due to a novel, poorly understood pathogen are discussed here.


Assuntos
COVID-19 , Hospitais , Humanos , Pacientes Internados , Pandemias/prevenção & controle , RNA Viral , SARS-CoV-2
4.
Infect Control Hosp Epidemiol ; 41(2): 181-186, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31694731

RESUMO

OBJECTIVE: Healthcare-associated bloodstream infections (HABSIs) are a significant cause of mortality and morbidity in the neonatal intensive care unit (NICU) population. Our objectives were to review the epidemiology of HABSIs in our NICU and to examine the applicability of National Healthcare Safety Network (NHSN) definitions to the NICU population. METHODS: We performed a retrospective review of all neonates admitted to the 54-bed, level IV NICU at Yale-New Haven Children's Hospital with a HABSI between January 1, 2013, and December 31, 2018. Clinical definitions per NICU team and NHSN site-specific definitions used for source identification were compared using the McNemar χ2 test. RESULTS: We identified 86 HABSIs with an incidence rate of 0.80 per 1,000 patient days. Only 13% of these were CLABSIs. Both CLABSIs and non-catheter-related bloodstream infections occurred primarily in preterm neonates, but the latter were associated with a significantly higher incidence of comorbidities and the need for respiratory support. The NHSN definitions were less likely to identify a source compared to the clinical definitions agreed upon by our NICU treating team (P < .001). Furthermore, 50% of patients without an identified source of infection by NHSN definitions were bacteremic with a mucosal barrier injury organism, likely from gut translocation. CONCLUSIONS: HABSIs occur primarily in premature infants with comorbidities, and CLABSIs account for a small proportion of these infections. With the increasing focus on HABSI prevention, there is a need for better NHSN site-specific definitions for the NICU population to prevent misclassification and direct prevention efforts.


Assuntos
Bacteriemia/epidemiologia , Infecção Hospitalar/epidemiologia , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Bacteriemia/microbiologia , Bacteriemia/mortalidade , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/mortalidade , Connecticut/epidemiologia , Infecção Hospitalar/microbiologia , Infecção Hospitalar/mortalidade , Hospitais Pediátricos , Humanos , Incidência , Recém-Nascido , Análise de Regressão , Estudos Retrospectivos
5.
Nephrol Nurs J ; 46(6): 587-590, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31872988

RESUMO

Central venous catheter (CVC) vascular access is common among patients on hemodialysis. CVC use carries a substantial risk of central line-associated bloodstream infections (CLABSIs), costly events that place patients at a high risk of mortality. Our hospital and dialysis organization developed a cooperative strategy to reduce the rate of CLABSI among hospitalized patients on hemodialysis with a CVC. The program included the use of training and reporting tools to guide hospital staff with CLABSI prevention, as well as leadership committees to oversee the process. Fourteen CLABSIs were reported in the 17-month period prior to the implementation of the program, while no new CLABSIs occurred in the 30 months following implementation of the program. This prevention program effectively reduced the frequency of CLABSIs. Broader implementation of such programs may result in better outcomes and lower costs for hospitalized patients on hemodialysis.


Assuntos
Bacteriemia , Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Bacteriemia/prevenção & controle , Infecções Relacionadas a Cateter/prevenção & controle , Humanos , Diálise Renal
6.
Infect Control Hosp Epidemiol ; 37(6): 667-72, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27004524

RESUMO

OBJECTIVE To evaluate ultraviolet C (UV-C) irradiance, UV-C dosage, and antimicrobial effect achieved by a mobile continuous UV-C device. DESIGN Prospective observational study. METHODS We used 6 UV light sensors to determine UV-C irradiance (W/cm2) and UV-C dosage (µWsec/cm2) at various distances from and orientations relative to the UV-C device during 5-minute and 15-minute cycles in an ICU room and a surgical ward room. In both rooms, stainless-steel disks inoculated with methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores were placed next to sensors, and UV-C dosages and log10 reductions of target organisms achieved during 5-minute and 15-minute cycles were determined. Mean irradiance and dosage readings were compared using ANOVA. RESULTS Mean UV-C irradiance was nearly 1.0E-03 W/cm2 in direct sight at a distance of 1.3 m (4 ft) from the device but was 1.12E-05 W/cm2 on a horizontal surface in a shaded area 3.3 m (10 ft) from the device (P4 to 1-3 for MRSA, >4 to 1-2 for VRE and >4 to 0 log10 for C. difficile spores, depending on the distance from, and orientation relative to, the device with 5-minute and 15-minute cycles. CONCLUSION UV-C irradiance, dosage, and antimicrobial effect received from a mobile UV-C device varied substantially based on location in a room relative to the UV-C device. Infect Control Hosp Epidemiol 2016;37:667-672.


Assuntos
Desinfecção/métodos , Quartos de Pacientes , Raios Ultravioleta , Clostridioides difficile/efeitos da radiação , Relação Dose-Resposta à Radiação , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Estudos Prospectivos , Enterococos Resistentes à Vancomicina/efeitos da radiação
7.
J Clin Microbiol ; 53(1): 113-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25355767

RESUMO

Outbreaks and pseudo-outbreaks of infection related to bronchoscopy typically involve Gram-negative bacteria, Mycobacterium species or Legionella species. We report an unusual bronchoscopy-related pseudo-outbreak due to Actinomyces graevenitzii. Extensive epidemiological and microbiological investigation failed to identify a common source. Strain typing revealed that the cluster was comprised of heterogeneous strains of A. graevenitzii. A change in laboratory procedures for Actinomyces cultures was coincident with the emergence of the pseudo-outbreak, and we determined that A. graevenitzii isolates more readily adopted a white, dry, molar tooth appearance on anaerobic colistin nalidixic acid (CNA) agar which likely facilitated its detection and identification in bronchoscopic specimens. This unusual pseudo-outbreak was related to frequent requests of bronchoscopists for Actinomyces cultures combined with a change in microbiology laboratory practices.


Assuntos
Actinomyces/classificação , Actinomicose/epidemiologia , Actinomicose/microbiologia , Broncoscopia/efeitos adversos , Infecção Hospitalar , Contaminação de Equipamentos , Actinomyces/genética , Carga Bacteriana , Estudos de Casos e Controles , Surtos de Doenças , Humanos , Reação em Cadeia da Polimerase , Centros de Atenção Terciária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...