Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Glaucoma ; 32(11): 976-982, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37725790

RESUMO

PRCIS: Juvenile open angle glaucoma (JOAG) patients with thick central corneas and negative family history were more likely to undergo surgery, mainly trabeculectomy with half requiring additional surgery within 10 years. PURPOSE: To assess the characteristics and treatment outcomes of patients with JOAG in Thailand. PATIENTS AND METHODS: This retrospective, multicenter study included all patients diagnosed with JOAG over 12 years from 2 tertiary hospitals in Bangkok, Thailand. RESULTS: A total of 200 eyes from 104 patients were included in this study. The mean age of onset was 24.0±10.1 years (range: 5-40 y), with male predominance (60.5%). Over 90% of patients had bilateral JOAG and 25% had a positive family history. Negative family history (adjusted odds ratio=4.59, P =0.02) and thick central corneal thickness were surgical predictors (every 10 µm adjusted odds ratio=1.29, P =0.01). Over 70% of cases needed glaucoma surgery. Trabeculectomy with Mitomycin-C was performed on 131 eyes (65.5%) with a cumulative probability of complete success of 71.0%, 57.8%, 39.2%, and 26.9% and qualified success of 86.3%, 73.6%, 64.8%, and 45.7% at 1, 3, 5, and 10 years, respectively. The mean follow-up after surgery was 94.9 ± 69.8 months (range: 13-153 mo). There were no serious postoperative complications. Myopia and the number of baseline glaucoma medications were significantly associated with surgical failure. CONCLUSIONS: Trabeculectomy with mitomycin C was the most common primary surgery performed in Thai patients with JOAG, and successfully reduced intraocular pressure without significant complications. Patients with thicker corneas were more likely to undergo surgery. By 10 years, half of the patients required additional surgery and risk factors for failure included myopia and the number of medications.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Miopia , Trabeculectomia , Humanos , Masculino , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/epidemiologia , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Estudos Retrospectivos , Tailândia/epidemiologia , Seguimentos , Glaucoma/cirurgia , Resultado do Tratamento , Mitomicina/uso terapêutico , Córnea , Miopia/cirurgia
2.
BMJ Open Ophthalmol ; 7(1): e000931, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402728

RESUMO

Objective: To evaluate the diagnostic performance of manual grading of anterior segment optical coherence tomography (AS-OCT) in detection of plateau iris configuration (PIC) based on the presence of standardised ultrasound biomicroscopy (UBM) criteria in at least two quadrants; namely, clinical diagnosis of PIC (DxPIC). Methods and analysis: In this cross-sectional study, paired AS-OCT and UBM images were evaluated by three glaucoma specialists. AS-OCT was classified into two mechanisms, PIC versus non-PIC, of primary angle closure disease (PACD) and AS-OCT-PIC diagnostic performance was tested with DxPIC. Results: One hundred and seventy-nine eyes of 142 patients were enrolled for analysis, and DxPIC was found in 85 eyes (47.49%). Intraobserver agreement rates of AS-OCT classification by the graders were 0.77, 0.701 and 0.742 (all p<0.001), and interobserver agreement rates, between a senior glaucoma specialist and the other two glaucoma specialists, were 0.68 and 0.702 (all p<0.001). Plateau iris was classified in AS-OCT images by the three graders, rated 32.96%-39.1% and 24.58%-34.08% in the horizontal and vertical axes, respectively. Diagnostic performance was analysed, yielding sensitivity ranging from 56.47% to 77.78%, and specificity of 48.94% to 64.29%. We applied disease prevalence of 30%, revealing positive predictive values varying from 32.16% to 44.44%, and negative predictive values of 72.4% to 85.71%. Accuracy ranged from 51.2% to 65%. Agreement between the two devices was fair, kappa range 0.31-0.351. Conclusion: Performance of manual grading of AS-OCT in detection of DxPIC was relatively poor; therefore, unadjusted AS-OCT does not appear to be good for manual PIC screening in PACD patients and cannot serve as a substitute for UBM in PIC detection.


Assuntos
Glaucoma , Doenças da Íris , Estudos Transversais , Glaucoma/diagnóstico , Gonioscopia , Humanos , Iris/diagnóstico por imagem , Doenças da Íris/diagnóstico , Tomografia de Coerência Óptica/métodos
3.
Sci Rep ; 12(1): 3602, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-35246594

RESUMO

To evaluate the performance of a new swept source optical coherence tomography optical biometer, ANTERION, in ocular biometry and intraocular lens (IOL) calculation compared with the reference standard of Dual Scheimpflug Analyzer (GALILEI, G6). A prospective comparative study was conducted in a tertiary eye center. Cataract patients were scanned with both devices in a random fashion, and parameters from the devices were analyzed in terms of mean difference and intraclass correlation coefficient (ICC). Bland-Altman plots were performed to compare agreement between the devices. Ninety-six eyes from 96 patients were enrolled for evaluation. With the exception of ACD, all parameters were significantly different, but excellent agreement was revealed for all of them. The mean difference in axial length was 0.03 mm, and ICC was 0.999. Calculated IOL power with Barrett formula revealed that 93.75% were within 1 diopter and the prediction error was 0.03 diopter. Biometry of the devices were arithmetically different. However, the mean difference of the key factors in IOL calculation were small and appeared to be negligible for the purposes of clinical application. The performance of ANTERION was comparable to that of G6 in biometric measurement and IOL calculation; however, the devices cannot be used interchangeably.


Assuntos
Comprimento Axial do Olho , Tomografia de Coerência Óptica , Comprimento Axial do Olho/anatomia & histologia , Biometria/métodos , Humanos , Interferometria , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...