Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Mater ; 36(16): e2304724, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37653576

RESUMO

Fluorescence-guided surgery (FGS) is poised to revolutionize surgical medicine through near-infrared (NIR) fluorophores for tissue- and disease-specific contrast. Clinical open and laparoscopic FGS vision systems operate nearly exclusively at NIR wavelengths. However, tissue-specific NIR contrast agents compatible with clinically available imaging systems are lacking, leaving nerve tissue identification during prostatectomy a persistent challenge. Here, it is shown that combining drug-like molecular design concepts and fluorophore chemistry enabled the production of a library of NIR phenoxazine-based fluorophores for intraoperative nerve-specific imaging. The lead candidate readily delineated prostatic nerves in the canine and iliac plexus in the swine using the clinical da Vinci Surgical System that has been popularized for minimally invasive prostatectomy procedures. These results demonstrate the feasibility of molecular engineering of NIR nerve-binding fluorophores for ready integration into the existing surgical workflow, paving the path for clinical translation to reduce morbidity from nerve injury for prostate cancer patients.


Assuntos
Tecido Nervoso , Oxazinas , Neoplasias da Próstata , Masculino , Humanos , Animais , Cães , Suínos , Corantes Fluorescentes/química , Prostatectomia/métodos
2.
Eur Urol Oncol ; 7(1): 63-72, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37516587

RESUMO

BACKGROUND: Men with high-risk prostate cancer undergoing surgery likely recur due to failure to completely excise regional and/or local disease. OBJECTIVE: The first-in-human evaluation of safety, pharmacokinetics, and exploratory efficacy of IS-002, a novel near-infrared prostate-specific membrane antigen (PSMA)-targeted fluorescence imaging agent, designed for intraoperative prostate cancer visualization. DESIGN, SETTING, AND PARTICIPANTS: A phase 1, single-center, dose-escalation study was conducted in 24 men with high-risk prostate cancer scheduled for robotic-assisted radical prostatectomy with (extended) pelvic lymph node dissection using the da Vinci surgical system. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Adverse events (AEs), vital signs, complete blood count, complete metabolic panel, urinalysis, and electrocardiogram were assessed over a 14-d period and compared with baseline. The pharmacokinetic profile of IS-002 was determined. Diagnostic accuracy was assessed for exploratory efficacy. RESULTS AND LIMITATIONS: AEs predominantly included discoloration of urine (n = 22/24; expected, related, grade 1). There were no grade ≥2 AEs. IS-002 Cmax and area under the curve increased with increasing dose. Plasma concentrations declined rapidly in a biphasic manner, with the median terminal half-lives ranging from 5.0 to 7.6 h, independent of dose and renal function. At 25 µg/kg, the exploratory efficacy readouts for the negative and positive predictive values were, 97% and 45% for lymph nodes, and 100% and 80% for residual/locoregional disease detection, respectively. CONCLUSIONS: IS-002 is safe and well tolerated, and has the potential to enable intraoperative tumor detection that could not be identified using standard imaging. PATIENT SUMMARY: IS-002 is a new imaging agent that specifically targets the prostate-specific membrane antigen receptor. In this study, we tested IS-002 for the first time in men with high-risk prostate cancer undergoing surgery and found that IS-002 is safe, is cleared from the body quickly, and potentially allows identification of prostate cancer in areas that would not be identified by conventional white light imaging.


Assuntos
Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Próstata/patologia , Recidiva Local de Neoplasia/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Prostatectomia/métodos
3.
Biomaterials ; 284: 121490, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35395454

RESUMO

Iatrogenic nerve injury significantly affects surgical outcomes. Although intraoperative neuromonitoring is utilized, nerve identification remains challenging and the success of nerve sparing is strongly correlated with surgeon experience levels. Fluorescence guided surgery (FGS) offers a potential solution for improved nerve sparing by providing direct visualization of nerve tissue intraoperatively. However, novel probes for FGS face a long regulatory pathway to achieve clinical translation. Herein, we report on the development of a clinically-viable, gel-based formulation that enables direct administration of nerve-specific probes for nerve sparing FGS applications, facilitating clinical translation via the exploratory investigational new drug (eIND) guidance. The developed formulation possesses unique gelling characteristics, allowing it to be easily spread as a liquid followed by rapid gelling for subsequent tissue hold. Optimization of the direct administration protocol with our gel-based formulation enabled a total staining time of 1-2 min for compatibility with surgical procedures and successful clinical translation.


Assuntos
Corantes Fluorescentes , Tecido Nervoso , Géis , Humanos , Doença Iatrogênica
4.
Adv Ther (Weinh) ; 4(7)2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34423111

RESUMO

Nerves are extremely difficult to identify and are often accidently damaged during surgery, leaving patients with lasting pain and numbness. Herein, a novel near-infrared (NIR) nerve-specific fluorophore, LGW01-08, was utilized for enhanced nerve identification using fluorescence guided surgery (FGS), formulated using clinical translatable strategies. Formulated LGW01-08 was examined for toxicology, pharmacokinetics (PK), and pharmacodynamics (PD) parameters in preparation for future clinical translation. Optimal LGW01-08 imaging doses were identified in each formulation resulting in a 10x difference between the toxicity to imaging dose window. Laparoscopic swine surgery completed using the da Vinci surgical robot (Intuitive Surgical) demonstrated the efficacy of formulated LGW01-08 for enhanced nerve identification. NIR fluorescence imaging enabled clear identification of nerves buried beneath ~3 mm of tissue that were unidentifiable by white light imaging. These studies provide a strong basis for future clinical translation of NIR nerve-specific fluorophores for utility during FGS to improve patient outcomes.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36053248

RESUMO

Nerve damage is a major complication of surgery, causing pain and loss of function. We have identified novel near-infrared nerve-specific fluorophores that provide excellent nerve contrast with the ability to identify buried nerve tissue.

6.
Sci Transl Med ; 12(542)2020 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-32376766

RESUMO

Nerve-binding fluorophores with near-infrared (NIR; 650 to 900 nm) emission could reduce iatrogenic nerve injury rates by providing surgeons precise, real-time visualization of the peripheral nervous system. Unfortunately, current systemically administered nerve contrast agents predominantly emit at visible wavelengths and show nonspecific uptake in surrounding tissues such as adipose, muscle, and facia, thus limiting detection to surgically exposed surface-level nerves. Here, a focused NIR fluorophore library was synthesized and screened through multi-tiered optical and pharmacological assays to identify nerve-binding fluorophore candidates for clinical translation. NIR nerve probes enabled micrometer-scale nerve visualization at the greatest reported tissue depths (~2 to 3 mm), a feat unachievable with previous visibly emissive contrast agents. Laparoscopic fluorescent surgical navigation delineated deep lumbar and iliac nerves in swine, most of which were invisible in conventional white-light endoscopy. Critically, NIR oxazines generated contrast against all key surgical tissue classes (muscle, adipose, vasculature, and fascia) with nerve signal-to-background ratios ranging from ~2 (2- to 3-mm depth) to 25 (exposed nerve). Clinical translation of NIR nerve-specific agents will substantially reduce comorbidities associated with surgical nerve damage.


Assuntos
Tecido Nervoso , Espectroscopia de Luz Próxima ao Infravermelho , Animais , Corantes Fluorescentes , Imagem Óptica , Suínos
7.
Adv Mater ; 32(11): e1907365, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32022975

RESUMO

Tumor-lymph node (LN) metastasis is the dominant prognostic factor for tumor staging and therapeutic decision-making. However, concurrently visualizing metastasis and performing imaging-guided lymph node surgery is challenging. Here, a multiplexed-near-infrared-II (NIR-II) in vivo imaging system using nonoverlapping NIR-II probes with markedly suppressed photon scattering and zero-autofluorescence is reported, which enables visualization of the metastatic tumor and the tumor metastatic proximal LNs resection. A bright and tumor-seeking donor-acceptor-donor (D-A-D) dye, IR-FD, is screened for primary/metastatic tumor imaging in the NIR-IIa (1100-1300 nm) window. This optimized D-A-D dye exhibits greatly improved quantum yield of organic D-A-D fluorophores in aqueous solutions (≈6.0%) and good in vivo performance. Ultrabright PbS/CdS core/shell quantum dots (QDs) with dense polymer coating are used to visualize cancer-invaded sentinel LNs in the NIR-IIb (>1500 nm) window. Compared to clinically used indocyanine green, the QDs show superior brightness and photostability (no obvious bleaching even after continuous laser irradiation for 5 h); thus, only a picomolar dose is required for sentinel LNs detection. This combination of dual-NIR-II image-guided surgery can be performed under bright light, adding to its convenience and appeal in clinical use.


Assuntos
Corantes Fluorescentes/química , Metástase Linfática/diagnóstico por imagem , Imagem Óptica/métodos , Pontos Quânticos/química , Linfonodo Sentinela/diagnóstico por imagem , Animais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Compostos de Cádmio/química , Linhagem Celular Tumoral , Feminino , Chumbo/química , Metástase Linfática/terapia , Camundongos , Polímeros/química , Compostos de Selênio/química , Linfonodo Sentinela/cirurgia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Cirurgia Assistida por Computador/métodos
8.
Sci Adv ; 5(9): eaaw0672, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31548981

RESUMO

NIR-II fluorescence imaging greatly reduces scattering coefficients for nearly all tissue types at long wavelengths, benefiting deep tissue imaging. However, most of the NIR-II fluorophores suffer from low quantum yields and/or short circulation time that limit the quality of NIR-II imaging. Here, we engineered a supramolecular assembly of protein complex with lodged cyanine dyes to produce a brilliant NIR-II fluorophore, providing a NIR-II quantum yield of 21.2% with prolonged circulation time. Computational modeling revealed the mechanism for fluorescence enhancement and identified key parameters governing albumin complex for NIR-II fluorophores. Our complex afforded high-resolution microvessel imaging, with a 3-hour imaging window compared to 2 min for free dye alone. Furthermore, the complexation strategy was applied to an antibody-derived assembly, offering high-contrast tumor imaging without affecting the targeting ability of the antibody. This study provides a facile strategy for producing high-performance NIR-II fluorophores by chaperoning cyanine dyes with functional proteins.


Assuntos
Meios de Contraste , Corantes Fluorescentes , Neoplasias Experimentais , Imagem Óptica , Soroalbumina Bovina , Animais , Bovinos , Meios de Contraste/química , Meios de Contraste/farmacocinética , Meios de Contraste/farmacologia , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Corantes Fluorescentes/farmacologia , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias Experimentais/irrigação sanguínea , Neoplasias Experimentais/diagnóstico por imagem , Soroalbumina Bovina/química , Soroalbumina Bovina/farmacocinética , Soroalbumina Bovina/farmacologia
9.
Adv Mater ; 31(24): e1900321, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31025403

RESUMO

Fluorescence bioimaging affords a vital tool for both researchers and surgeons to molecularly target a variety of biological tissues and processes. This review focuses on summarizing organic dyes emitting at a biological transparency window termed the near-infrared-II (NIR-II) window, where minimal light interaction with the surrounding tissues allows photons to travel nearly unperturbed throughout the body. NIR-II fluorescence imaging overcomes the penetration/contrast bottleneck of imaging in the visible region, making it a remarkable modality for early diagnosis of cancer and highly sensitive tumor surgery. Due to their convenient bioconjugation with peptides/antibodies, NIR-II molecular dyes are desirable candidates for targeted cancer imaging, significantly overcoming the autofluorescence/scattering issues for deep tissue molecular imaging. To promote the clinical translation of NIR-II bioimaging, advancements in the high-performance small molecule-derived probes are critically important. Here, molecules with clinical potential for NIR-II imaging are discussed, summarizing the synthesis and chemical structures of NIR-II dyes, chemical and optical properties of NIR-II dyes, bioconjugation and biological behavior of NIR-II dyes, whole body imaging with NIR-II dyes for cancer detection and surgery, as well as NIR-II fluorescence microscopy imaging. A key perspective on the direction of NIR-II molecular dyes for cancer imaging and surgery is also discussed.


Assuntos
Corantes/metabolismo , Raios Infravermelhos , Neoplasias/diagnóstico , Neoplasias/cirurgia , Imagem Óptica/métodos , Humanos , Neoplasias/metabolismo
10.
Theranostics ; 8(15): 4141-4151, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30128042

RESUMO

Significantly reduced photon scattering and minimal tissue autofluorescence levels in the second biological transparency window (NIR-II; 1000-1700 nm) facilitate higher resolution in vivo biological imaging compared to tradition NIR fluorophores (~700-900 nm). However, the existing palette of NIR-II fluorescent agents including semiconducting inorganic nanomaterials and recently introduced small-molecule organic dyes face significant technical and regulatory hurdles prior to clinical translation. Fortunately, recent spectroscopic characterization of NIR-I dyes (e.g., indocyanine green (ICG), IRDye800CW and IR-12N3) revealed long non-negligible emission tails reaching past 1500 nm. Repurposing the most widely used NIR dye in medicine, in addition to those in the midst of clinical trials creates an accelerated pathway for NIR-II clinical translation. This review focuses on the significant advantage of imaging past 1000 nm with NIR-I fluorophores from both a basic and clinical viewpoint. We further discuss optimizing NIR-I dyes around their NIR-II/shortwave infrared (SWIR) emission, NIR-II emission tail characteristics and prospects of NIR-II imaging with clinically available and commercially available dyes.


Assuntos
Radiação Eletromagnética , Corantes Fluorescentes/metabolismo , Imagem Óptica/métodos , Benzenossulfonatos/metabolismo , Verde de Indocianina/metabolismo , Indóis/metabolismo
11.
Adv Mater ; : e1802546, 2018 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-29985542

RESUMO

The significantly reduced tissue autofluorescence and scattering in the NIR-II region (1000-1700 nm) opens many exciting avenues for detailed investigation of biological processes in vivo. However, the existing NIR-II fluorescent agents, including many molecular dyes and inorganic nanomaterials, are primarily focused on complicated synthesis routes and unknown immunogenic responses with limited potential for clinical translation. Herein, the >1000 nm tail emission of conventional biocompatible NIR cyanine dyes with emission peaks at 700-900 nm is systematically investigated, and a type of bright dye for NIR-II imaging with high potential for accelerating clinical translation is identified. The asymmetry of the π domain in the S1 state of NIR cyanine dyes is proven to result in a twisted intramolecular charge-transfer process and NIR-II emission, establishing a general rule to guide future NIR-I/II fluorophore synthesis. The screened NIR dyes are identified to possess a bright emission tail in the NIR-II region along with high quantum yield, high molar-extinction coefficient, rapid fecal excretion, and functional groups amenable for bioconjugation. As a result, NIR cyanine dyes can be used for NIR-II imaging to afford superior contrast and real-time imaging of several biological models, facilitating the translation of NIR-II bioimaging to clinical theranostic applications.

12.
Nat Commun ; 9(1): 1171, 2018 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-29563581

RESUMO

Fluorescence imaging of biological systems in the second near-infrared (NIR-II, 1000-1700 nm) window has shown promise of high spatial resolution, low background, and deep tissue penetration owing to low autofluorescence and suppressed scattering of long wavelength photons. Here we develop a bright organic nanofluorophore (named p-FE) for high-performance biological imaging in the NIR-II window. The bright NIR-II >1100 nm fluorescence emission from p-FE affords non-invasive in vivo tracking of blood flow in mouse brain vessels. Excitingly, p-FE enables one-photon based, three-dimensional (3D) confocal imaging of vasculatures in fixed mouse brain tissue with a layer-by-layer imaging depth up to ~1.3 mm and sub-10 µm high spatial resolution. We also perform in vivo two-color fluorescence imaging in the NIR-II window by utilizing p-FE as a vasculature imaging agent emitting between 1100 and 1300 nm and single-walled carbon nanotubes (CNTs) emitting above 1500 nm to highlight tumors in mice.


Assuntos
Encéfalo/diagnóstico por imagem , Corantes Fluorescentes/farmacocinética , Imageamento Tridimensional/métodos , Nanotubos de Carbono/química , Imagem Óptica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/fisiologia , Encéfalo/irrigação sanguínea , Linhagem Celular Tumoral , Circulação Cerebrovascular/fisiologia , Feminino , Corantes Fluorescentes/síntese química , Imageamento Tridimensional/instrumentação , Injeções Subcutâneas , Glândulas Mamárias Animais/irrigação sanguínea , Glândulas Mamárias Animais/diagnóstico por imagem , Glândulas Mamárias Animais/patologia , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Transplante de Neoplasias , Imagem Óptica/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação
13.
Adv Mater ; 30(13): e1705799, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29446156

RESUMO

Greatly reduced scattering in the second near-infrared (NIR-II) region (1000-1700 nm) opens up many new exciting avenues of bioimaging research, yet NIR-II fluorescence imaging is mostly implemented by using nontargeted fluorophores or wide-field imaging setups, limiting the signal-to-background ratio and imaging penetration depth due to poor specific binding and out-of-focus signals. A newly developed high-performance NIR-II bioconjugate enables targeted imaging of a specific organ in the living body with high quality. Combined with a home-built NIR-II confocal set-up, the enhanced imaging technique allows 900 µm-deep 3D organ imaging without tissue clearing techniques. Bioconjugation of two hormones to nonoverlapping NIR-II fluorophores facilitates two-color imaging of different receptors, demonstrating unprecedented multicolor live molecular imaging across the NIR-II window. This deep tissue imaging of specific receptors in live animals allows development of noninvasive molecular imaging of multifarious models of normal and neoplastic organs in vivo, beyond the traditional visible to NIR-I range. The developed NIR-II fluorescence microscopy will become a powerful imaging technique for deep tissue imaging without any physical sectioning or clearing treatment of the tissue.

14.
Nat Commun ; 8(1): 737, 2017 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-28963467

RESUMO

In vivo fluorescence imaging in the near-infrared region between 1500-1700 nm (NIR-IIb window) affords high spatial resolution, deep-tissue penetration, and diminished auto-fluorescence due to the suppressed scattering of long-wavelength photons and large fluorophore Stokes shifts. However, very few NIR-IIb fluorescent probes exist currently. Here, we report the synthesis of a down-conversion luminescent rare-earth nanocrystal with cerium doping (Er/Ce co-doped NaYbF4 nanocrystal core with an inert NaYF4 shell). Ce doping is found to suppress the up-conversion pathway while boosting down-conversion by ~9-fold to produce bright 1550 nm luminescence under 980 nm excitation. Optimization of the inert shell coating surrounding the core and hydrophilic surface functionalization minimize the luminescence quenching effect by water. The resulting biocompatible, bright 1550 nm emitting nanoparticles enable fast in vivo imaging of blood vasculature in the mouse brain and hindlimb in the NIR-IIb window with short exposure time of 20 ms for rare-earth based probes.Fluorescence imaging in the near-infrared window between 1500-1700 nm (NIR-IIb window) offers superior spatial resolution and tissue penetration depth, but few NIR-IIb probes exist. Here, the authors synthesize rare earth down-converting nanocrystals as promising fluorescent probes for in vivo imaging in this spectral region.


Assuntos
Metais Terras Raras/química , Nanopartículas/química , Animais , Vasos Sanguíneos/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Cério/química , Érbio/química , Luminescência , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/métodos
15.
Chem Sci ; 8(5): 3703-3711, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28626555

RESUMO

In vivo imaging of hormone receptors provides the opportunity to visualize target tissues under hormonal control in live animals. Detecting longer-wavelength photons in the second near-infrared window (NIR-II, 1000-1700 nm) region affords reduced photon scattering in tissues accompanied by lower autofluorescence, leading to higher spatial resolution at up to centimeter tissue penetration depths. Here, we report the conjugation of a small molecular NIR-II fluorophore CH1055 to a follicle stimulating hormone (FSH-CH) for imaging ovaries and testes in live mice. After exposure to FSH-CH, specific NIR-II signals were found in cultured ovarian granulosa cells containing FSH receptors. Injection of FSH-CH allowed live imaging of ovarian follicles and testicular seminiferous tubules in female and male adult mice, respectively. Using prepubertal mice, NIR-II signals were detected in ovaries containing only preantral follicles. Resolving earlier controversies regarding the expression of FSH receptors in cultured osteoclasts, we detected for the first time specific FSH receptor signals in bones in vivo. The present imaging of FSH receptors in live animals using a ligand-conjugated NIR-II fluorophore with low cell toxicity and rapid clearance allows the development of non-invasive molecular imaging of diverse hormonal target cells in vivo.

16.
Nat Commun ; 8: 15269, 2017 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-28524850

RESUMO

Fluorescence imaging in the second near-infrared window (NIR-II) allows visualization of deep anatomical features with an unprecedented degree of clarity. NIR-II fluorophores draw from a broad spectrum of materials spanning semiconducting nanomaterials to organic molecular dyes, yet unfortunately all water-soluble organic molecules with >1,000 nm emission suffer from low quantum yields that have limited temporal resolution and penetration depth. Here, we report tailoring the supramolecular assemblies of protein complexes with a sulfonated NIR-II organic dye (CH-4T) to produce a brilliant 110-fold increase in fluorescence, resulting in the highest quantum yield molecular fluorophore thus far. The bright molecular complex allowed for the fastest video-rate imaging in the second NIR window with ∼50-fold reduced exposure times at a fast 50 frames-per-second (FPS) capable of resolving mouse cardiac cycles. In addition, we demonstrate that the NIR-II molecular complexes are superior to clinically approved ICG for lymph node imaging deep within the mouse body.


Assuntos
Corantes Fluorescentes/química , Ionóforos/química , Imagem Óptica , Espectroscopia de Luz Próxima ao Infravermelho , Animais , Feminino , Fluorescência , Linfonodos/patologia , Camundongos , Camundongos Nus , Nanoestruturas/química , Nanotubos de Carbono/química , Compostos Orgânicos/química , Teoria Quântica , Semicondutores , Gravação em Vídeo
17.
Proc Natl Acad Sci U S A ; 114(5): 962-967, 2017 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-28096386

RESUMO

Fluorescence imaging multiplicity of biological systems is an area of intense focus, currently limited to fluorescence channels in the visible and first near-infrared (NIR-I; ∼700-900 nm) spectral regions. The development of conjugatable fluorophores with longer wavelength emission is highly desired to afford more targeting channels, reduce background autofluorescence, and achieve deeper tissue imaging depths. We have developed NIR-II (1,000-1,700 nm) molecular imaging agents with a bright NIR-II fluorophore through high-efficiency click chemistry to specific molecular antibodies. Relying on buoyant density differences during density gradient ultracentrifugation separations, highly pure NIR-II fluorophore-antibody conjugates emitting ∼1,100 nm were obtained for use as molecular-specific NIR-II probes. This facilitated 3D staining of ∼170-µm histological brain tissues sections on a home-built confocal microscope, demonstrating multicolor molecular imaging across both the NIR-I and NIR-II windows (800-1,700 nm).


Assuntos
Química Encefálica , Encéfalo/ultraestrutura , Química Click , Técnica Direta de Fluorescência para Anticorpo/métodos , Corantes Fluorescentes/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , Biotinilação , Carcinoma de Células Escamosas/ultraestrutura , Cetuximab/análise , Imageamento Tridimensional , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Microscopia Confocal/métodos , Estrutura Molecular , Nanotubos , Ressonância Magnética Nuclear Biomolecular , Estreptavidina
18.
Biomaterials ; 103: 265-277, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27394161

RESUMO

The multimodality theranostic system, which can integrate two or more different therapeutic modalities and multimodal imaging agents into a nanoentity, shows great promising prospects for the cancer treatment. Herein, we developed an efficient and novel strategy to synthesize hybrid anisotropic nanoparticles (HANs) with intrinsic multimodal theranostic capability [chemotherapy, photothermal therapy, magnetic resonance imaging (MRI), and photoacoustic imaging (PAI)]. For the first time, under the guidance of MRI and PAI, the chemotherapy and thermotherapy induced by administration of multifunctional hybrid nanoprobes were applied simultaneously to the treatment of colon cancer-bearing mice in vivo.


Assuntos
Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/terapia , Hipertermia Induzida/métodos , Imageamento por Ressonância Magnética/métodos , Nanopartículas/química , Nanopartículas/uso terapêutico , Técnicas Fotoacústicas/métodos , Animais , Anisotropia , Linhagem Celular Tumoral , Terapia Combinada/métodos , Meios de Contraste/química , Tratamento Farmacológico/métodos , Feminino , Células HT29 , Humanos , Camundongos , Camundongos Nus , Imagem Multimodal/métodos , Nanomedicina Teranóstica/métodos , Resultado do Tratamento
19.
Adv Mater ; 28(32): 6872-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27253071

RESUMO

Traumatic brain injury (TBI) is a leading cause of death and disability worldwide. A bright, renal-excreted, and biocompatible near-infrared II fluorophore for in vivo imaging of TBI is designed. A transient hypoperfusion in the injured cerebral region, followed by fluorophore leakage, is observed. NIR-II fluorophores can provide noninvasive assessment of TBI.


Assuntos
Lesões Encefálicas Traumáticas/diagnóstico por imagem , Corantes Fluorescentes/análise , Animais , Modelos Animais de Doenças , Camundongos
20.
Nat Mater ; 15(2): 235-42, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26595119

RESUMO

Fluorescent imaging of biological systems in the second near-infrared window (NIR-II) can probe tissue at centimetre depths and achieve micrometre-scale resolution at depths of millimetres. Unfortunately, all current NIR-II fluorophores are excreted slowly and are largely retained within the reticuloendothelial system, making clinical translation nearly impossible. Here, we report a rapidly excreted NIR-II fluorophore (∼90% excreted through the kidneys within 24 h) based on a synthetic 970-Da organic molecule (CH1055). The fluorophore outperformed indocyanine green (ICG)-a clinically approved NIR-I dye-in resolving mouse lymphatic vasculature and sentinel lymphatic mapping near a tumour. High levels of uptake of PEGylated-CH1055 dye were observed in brain tumours in mice, suggesting that the dye was detected at a depth of ∼4 mm. The CH1055 dye also allowed targeted molecular imaging of tumours in vivo when conjugated with anti-EGFR Affibody. Moreover, a superior tumour-to-background signal ratio allowed precise image-guided tumour-removal surgery.


Assuntos
Benzopiranos/farmacologia , Carcinoma de Células Escamosas/patologia , Corantes Fluorescentes/farmacologia , Indóis/farmacologia , Neoplasias Experimentais/patologia , Fenilpropionatos/farmacologia , Tiadiazóis/farmacologia , Animais , Benzopiranos/química , Benzopiranos/urina , Linhagem Celular Tumoral , Diagnóstico por Imagem/métodos , Feminino , Humanos , Indóis/química , Indóis/urina , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Espectroscopia de Luz Próxima ao Infravermelho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...