Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
World J Gastrointest Endosc ; 14(10): 636-641, 2022 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-36303813

RESUMO

BACKGROUND: Esophageal cancer is a common type of cancer and serious bleeding from esophageal tumors can occur in routine clinical practice. The arrest of bleeding from esophageal tumor is not a trivial task, which can sometimes require nonstandard solutions. We report a case of successful hemostasis of massive bleeding from esophageal tumor performed by a novel two-balloon catheter inserted endoscopically, with a local hemostatic treatment applied. CASE SUMMARY: A 36-years old male patient with advanced esophageal cancer developed bleeding from the tumor following endoscopic stenting with a self-expanding metal stent. Due to the ineffectiveness of standard approaches, after a medical conference, the patient was treated with a novel method based on the use of a two-balloon catheter creating an isolated area in esophagus and locally dispersing hemostatic polysaccharide powder inside the isolated interior. Hemostasis was successful and subsequent endoscopic examination revealed the presence of organized clot and localized defect, which was coagulated in a planned manner. CONCLUSION: The authors present a new catheter-based method of hemostasis of esophageal tumor bleeding.

2.
United European Gastroenterol J ; 5(2): 276-283, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28344796

RESUMO

BACKGROUND: The quality of colonoscopy has been related to a higher risk of interval cancer, and this issue has been addressed extensively in developed countries. The aim of our study was to explore the main quality indicators of colonoscopy in a large emerging country. METHODS: Consecutive patients referred for colonoscopy in 14 centres were prospectively included between July and October 2014. Before colonoscopy, several clinical and demographic variables were collected. Main quality indicators (i.e. caecal intubation rate, (advanced) adenoma detection rate, rate of adequate cleansing and sedation) were collected. Data were analysed at per patient and per centre level (only for those with at least 100 cases). Factors associated with caecal intubation rate and adenoma detection rate were explored at multivariate analysis. RESULTS: A total of 8829 (males: 35%; mean age: 57 + 14 years) patients were included, with 11 centres enrolling at least 100 patients. Screening (including non-alarm symptoms) accounted for 59% (5188/8829) of the indications. Sedation and split preparation were used in 26% (2294/8829) and 25% (2187/8829) of the patients. Caecal intubation was achieved in 7616 patients (86%), and it was ≥85% in 8/11 (73%) centres. Adenoma detection rate was 18% (1550/8829), and it was higher than 20% in five (45%) centres, whilst it was lower than 10% in four (33%) centres. At multivariate analysis, age (OR: 1.020, 95% CI: 1.015-1.024), male sex (OR: 1.2, 95% CI: 1.1-1.3), alarm symptoms (OR: 1.8, 95% CI: 1.7-2), split preparation (OR: 1.4, 95% CI: 1.2-1.6), caecal intubation rate (OR: 1.6, 95% CI: 1.3-1.9) and withdrawal time measurement (OR: 1.2, 95% CI: 1.6-2.1) were predictors of a higher adenoma detection rate, while adequate preparation (OR: 3.4: 95% CI: 2.9-3.9) and sedation (OR: 1.3; 95% CI: 1.1-1.6) were the strongest predictors of caecal intubation rate. CONCLUSIONS: According to our study, there is a substantial intercentre variability in the main quality indicators. Overall, the caecal intubation rate appears to be acceptable in most centres, whilst the overall level of adenoma detection appears low, with less than half of the centres being higher than 20%. Educational and quality assurance programs, including higher rates of sedation and split regimen of preparation, may be necessary to increase the key quality indicators.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...