Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 6: 6376, 2015 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-25757227

RESUMO

Owing to food scarcity and to the high densities that vertebrates often reach on islands, typical insect- and seed-eaters widen their feeding niche and interact with a greater fraction of species than their mainland counterparts. This phenomenon, coined here 'interaction release', has been previously reported for single species but never for an entire community. During 4 years, we gathered data on bird-flower visitation on 12 Galápagos islands. We show that all sampled land birds exploit floral resources and act as potential pollinators across the entire archipelago, in all major habitats and all year round. Although species and link composition varies among islands, strong interaction release takes place on all islands, making their bird-flower network highly generalized. Interaction release is crucial to the survival of native birds but simultaneously threatens the unique biodiversity of this archipelago, as the birds also visit invading plants, likely facilitating their integration into pristine native communities.


Assuntos
Aves/fisiologia , Flores/fisiologia , Dispersão Vegetal/fisiologia , Polinização/fisiologia , Animais , Biodiversidade , Comportamento Competitivo/fisiologia , Equador , Comportamento Alimentar/fisiologia , Cadeia Alimentar , Insetos/fisiologia , Espécies Introduzidas/tendências , Plantas
2.
Med Phys ; 40(1): 011721, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23298091

RESUMO

PURPOSE: The aim of this work is the application of the formalism for ionization chamber reference dosimetry of small and nonstandard fields [R. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjäll, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich, and S. Vatnitsky, "A new formalism for reference dosimetry of small and nonstandard fields," Med. Phys. 35, 5179-5186 (2008)] to the CyberKnife robotic radiosurgery system. Correction factors for intermediate calibration fields, a machine-specific reference field (msr) and two plan-class specific reference fields (pcsr), have been studied. Furthermore, the applicability of the new formalism to clinical dosimetry has been analyzed through the investigation of two clinical treatments. METHODS: PTW31014 and Scanditronix-Wellhofer CC13 ionization chamber measurements were performed for the fields under investigation. Absorbed dose to water was determined using alanine reference dosimetry, and experimental correction factors were calculated from alanine to ionization chamber readings ratios. In addition, correction factors were calculated for the intermediate calibration fields and one of the clinical treatment fields using the Monte Carlo method and these were compared with the experimental values. RESULTS: Overall correction factors deviating from unity by approximately 2% were obtained from both measurements and simulations, with values below and above unity for the studied intermediate calibration fields and clinical fields for the ionization chambers under consideration. Monte Carlo simulations yielded correction factors comparable with those obtained from measurements for the machine-specific reference field, although differences from 1% to 3.3% were observed between measured and calculated correction factors for the composite intermediate calibration fields. Dose distribution inhomogeneities are thought to be responsible for such discrepancies. CONCLUSIONS: The differences found between overall correction factors associated with the proposed intermediate calibration fields and the clinical fields under investigation show that depending on the clinical field and the detector used, either a machine-specific reference field or a plan-class specific reference field is more representative for the clinical field. Given the experimental and numerical uncertainties and the small number of clinical fields considered in this study the significance of these observations is limited and it remains unclear for the CyberKnife if there would be a significant gain in using a pcsr field rather than a msr field as reference field for relative dosimetry.


Assuntos
Radiometria/instrumentação , Radiocirurgia/métodos , Humanos , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador , Incerteza