Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Semin Thorac Cardiovasc Surg ; 28(2): 271-280, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28043429

RESUMO

Interest in minimally invasive video-assisted mitral valve surgery (MIMVS) is rapidly growing. Data on concomitant atrial fibrillation (AF) ablation to MIMVS are still lacking. The present study investigates the long-term results of AF cryoablation concomitant to MIMVS. From October 2006-September 2014, 68 patients with mitral valve disease (age 65.9 ± 11.1 years, 34 men out of 68 patients, Euroscore log 5.4 ± 4.5) and drug-resistant AF underwent MIMVS via right minithoracotomy and concomitant left-sided AF endocardial cryoablation (Cryoflex Medtronic, Minneapolis, MN). Patients were independently followed up by cardiological outpatient visits and underwent electrophysiological study when indicated. In total, 44 out of 68 patients (64.7%) underwent mitral valve repair and 8 patients (11.8%) also received concomitant tricuspid valve surgery. One procedure was electively converted to full sternotomy (1.5%). Total clamp time was 97.6 ± 22.8 minutes. In March 2015, 60 patients were alive and completed the follow-up after a mean of 3.4 ± 2.0 years following the procedure. In all, 48 patients (80%) presented sinus rhythm throughout the whole follow-up. Freedom from AF was respectively 95%, 87%, and 72% at 1, 3, and 5 years, respectively. We recorded 2 pacemaker implants (3.3%). A total of 3 patients suffered symptomatic recurrences (2 atypical atrial flutter and 1 atrial fibrillation) and underwent transcatheter ablation-all the 3 patients remained in stable sinus rhythm for the remaining follow-up. In conclusions, given the favorable long-term sinus rhythm maintenance rates of concomitant cryoablation, MIMVS can also be offered to patients with symptomatic AF. AF transcatheter ablation may easily avoid further symptomatic recurrences.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Criocirurgia , Doenças das Valvas Cardíacas/cirurgia , Valva Mitral/cirurgia , Toracotomia , Cirurgia Vídeoassistida , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/etiologia , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/cirurgia , Cirurgia Vídeoassistida/efeitos adversos
2.
J Cardiovasc Med (Hagerstown) ; 17(12): 863-869, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25379716

RESUMO

BACKGROUND: Atrial fibrillation is responsible for up to one-third of ischemic strokes, and is also associated with silent cerebral infarctions and transient ischemic attacks (TIAs). The self-terminating and often asymptomatic nature of paroxysmal atrial fibrillation (PAF) may lead to its underdiagnosis. A continuous and long-term heart rhythm monitoring can be useful in unmasking PAF episodes. OBJECTIVE: Prevalence of asymptomatic PAF in patients suffering a cryptogenic stroke, at risk for atrial fibrillation but without any history of arrhythmia or palpitations, using a continuous electrocardiographic monitoring. METHODS: One hundred and forty-two consecutive patients were admitted to the Stroke Unit of 'Città della Salute e della Scienza' Hospital of Turin between June 2010 and March 2013 and discharged with the diagnosis of ischemic cryptogenic stroke. Sixty fulfilled predefined inclusion criteria. Follow-up was carried on and completed for the 54 patients who consented to implantable loop recorder (ILR) implantation. After ILR implantation, trans-telephonic data were collected monthly. RESULTS: Atrial fibrillation episodes lasting more than 5 min were recorded in 25 patients (46%), median detection time was 5.4 months (range 1-18) and median duration of atrial fibrillation episodes was 20 h (range 7 min-8 days) with 19 patients (76%) remaining asymptomatic and the others experiencing weakness and dyspnoea but not palpitations. CONCLUSION: Long-term heart rhythm monitoring is successful in unmasking silent atrial fibrillation in 46% of patients suffering a cryptogenic stroke with concomitant atrial fibrillation risk factors, but without history of arrhythmia or palpitations.


Assuntos
Doenças Assintomáticas/epidemiologia , Fibrilação Atrial/diagnóstico , Ataque Isquêmico Transitório/diagnóstico por imagem , Acidente Vascular Cerebral/complicações , Taquicardia Supraventricular/diagnóstico , Idoso , Fibrilação Atrial/epidemiologia , Ecocardiografia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Ataque Isquêmico Transitório/etiologia , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Prevenção Secundária
3.
Circ J ; 79(12): 2576-83, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26447119

RESUMO

BACKGROUND: Data are lacking on the effect of radiofrequency catheter ablation (RFCA) on atrial function. The aim of this study was to determine a cut-off of pre-ablation left atrial (LA) function in order to predict atrial functional recovery after RFCA. METHODS AND RESULTS: A total of 64 atrial fibrillation (AF) patients who underwent RFCA were enrolled (age, 59.05±12.09 years; 36% persistent AF; LA volume 37.8±13.6 ml/m(2)). LA emptying fraction (LAEF), LA active fraction (LAAEF), LA passive emptying fraction (LAPEF) and LA expansion index (LAEI) were evaluated in sinus rhythm before and 48 h, 15 days, 1, 2, 3 and 9 months after ablation. LA function improvement was defined as any positive increase in LAEF compared with baseline. On univariate and multivariate analysis only baseline atrial function proved to be an independent predictor of LA function improvement after ablation (P=0.002; OR=0.001; 95% CI: 0.000-0.099). On receiver operating characteristic analysis (AUC=0.70), cut-off for baseline LAEF was 40%. At 9 months, patients with LAEF <40% had significant improvement in atrial performance (LAEF, P=0.01; LAAEF, P=0.036; LAEI, P=0.004); a significant negative correlation between baseline LAEF and LA function improvement was observed (r=-0.62; 95% CI: -0.83 to -0.26; P(r=0)<0.002). CONCLUSIONS: Baseline LAEF is an independent predictor of LA function recovery after RFCA. The beneficial effect of AF ablation is most evident in patients with LAEF<40%.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter , Recuperação de Função Fisiológica , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
4.
Eur Heart J Cardiovasc Imaging ; 16(3): 335-41, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25274966

RESUMO

AIMS: Little is known about the impact of left-ventricular (LV) diastolic dysfunction on risk of atrial fibrillation (AF) recurrence in patients with left-atrial (LA) dilation. To evaluate, in patients with symptomatic persistent AF and LA dilation, the incremental role of LV diastolic dysfunction in predicting early AF recurrence after cardioversion (CV). METHODS AND RESULTS: From July 2011 to July 2013, 175 patients with persistent AF referred to our centre for CV were screened. Inclusion criteria were: European Heart Rhythm Association (EHRA) class ≥2 despite optimal medical treatment and heart rate at rest ≤80 bpm, LA volume ≥34 mL/m(2), EF > 35%, absence of untreated ischaemic disease and significant valvular disease, successful CV. Finally, 127 patients (age 64 ± 10 years, 60% EHRA ≥3, LA volume 42 ± 15 mL/m(2)) were enrolled. At 3 months, 37 (29%) patients presented AF recurrence. At univariate analysis, AF duration >90 days before CV (P < 0.01), septal e' <8 cm/s (P 0.03), and septal E/e' ratio ≥11 (P < 0.001) but no LA dimensions significantly correlated with AF recurrence. Logistic regression analysis confirmed septal E/e' ratio ≥11 as the best predictor of recurrence (OR 3.25 95% CI 1.19-8.86 P 0.001) together with an AF duration >90 days before the CV (OR 2.69 95% CI 1.01-7.53 P 0.04). At ROC curve analysis, the septal E/e' ratio ≥11 showed the best diagnostic accuracy (AUC 0.66, 95% CI 0.55-0.76, P 0.007). CONCLUSION: In this population with symptomatic persistent AF and LA enlargement, septal E/e' ratio ≥11 and AF duration >90 days predicted AF recurrence at 3 months.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Átrios do Coração/patologia , Interpretação de Imagem Assistida por Computador , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Fibrilação Atrial/diagnóstico , Estudos de Coortes , Ecocardiografia Doppler de Pulso/métodos , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Hipertrofia/patologia , Incidência , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Recidiva , Estudos Retrospectivos , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda/fisiopatologia
5.
J Card Fail ; 18(12): 886-93, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23207075

RESUMO

BACKGROUND: Right ventricular (RV) function plays a pivotal role in advanced heart failure patients, especially for screening those who may benefit from left ventricular assist device (LVAD) implantation. We introduce RV contraction pressure index (RVCPI) as a new echo-Doppler parameter of RV function. The accuracy of RVCPI in detecting RV failure was compared with the criterion standard, the RV stroke work index (RVSWI) obtained through right heart catheterization in advanced heart failure patients referred for heart transplantation or LVAD implantation. METHODS AND RESULTS: Right heart catheterization and echo-Doppler were simultaneously performed in 94 consecutive patients referred to our center for advanced heart failure (ejection fraction (EF) 24 ± 8.8%, 40% NYHA functional class IV). RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. Simplified RVCPI (sRVCPI) was derived as TAPSE × (RV - right atrial pressure gradient). Close positive correlation between sRVCPI and RVSWI was found (r = 0.68; P < .001). With logistic regression, we found that increased sRVCPI showed an independent reduced risk (odds ratio 0.98, 95% confidence interval [CI] 0.97-0.99; P = .016) for patients to present a depressed RVSWI (<0.25 mm Hg/L·m(2)). Simplified RVCPI showed high diagnostic accuracy (area under the receiver operating characteristic curve 0.94, 95% CI 0.89-0.99) and good sensitivity and specificity (92% and 85%, respectively) to predict depressed RVSWI with the use of a cutoff value of <400 mm·mm Hg. CONCLUSIONS: In patients with advanced heart failure, the new simple bedside sRVCPI closely correlated with RVSWI, providing an independent, noninvasive, and easy tool for the evaluation of RV function.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica/fisiologia , Volume Sistólico/fisiologia , Disfunção Ventricular Direita/diagnóstico , Função Ventricular Direita/fisiologia , Cateterismo Cardíaco , Ecocardiografia Doppler , Feminino , Humanos , Hipertrofia Ventricular Direita/diagnóstico por imagem , Hipertrofia Ventricular Direita/fisiopatologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Direita/fisiopatologia
6.
Congest Heart Fail ; 15(1): 14-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19187402

RESUMO

Large evidence supports the importance of individualized optimization of cardiac resynchronization therapy in patients with congestive heart failure. The aim of this study was to compare a recently developed intracardiac electrogram (IEGM)-based method with the Doppler echocardiographic (ECHO)-based method to calculate optimal atrioventricular (AV) and interventricular (VV) delays. Ten male patients implanted with a St Jude Medical resynchronization device received AV and VV delay assessment with both the IEGM and the ECHO-based methods. Estimates of the optimal AV and VV delays assessed by the 2 tested methods proved highly comparable. No difference emerged between the IEGM (126.8+/-22.7) and the ECHO (127.3+/-19.8) AV delay values (P=.987). The VV delay suggested by ECHO was highly significantly correlated with the delays calculated by the IEGM method (35+/-27.6 vs 21.31+/-24.31; r(2)=0.78; P<.001). These preliminary data support the evidence that an IEGM based cardiac resynchronization optimization method may be as reliable as a complete ECHO assessment.


Assuntos
Algoritmos , Estimulação Cardíaca Artificial , Ecocardiografia Doppler de Pulso , Insuficiência Cardíaca/terapia , Idoso , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...