1.
Radiat Prot Dosimetry ; 199(3): ncac267 254 261-261, 2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36566495

RESUMO

The establishment of typical diagnostic reference levels (DRLs) values according to the complexity indices (CIs) for hepatic chemoembolisation (HC), iliac stent placement (ISP) and femoropopliteal revascularisation (FR) is reported in this study. To estimate patients' stochastic effects, effective dose was calculated through dose area product (DAP) values of this study and E/DAP conversion factors derived from the literature. Data for DAP, Reference Air Kerma (Ka,r) and fluoroscopy time (FT) were collected for 218 patients and CIs were assigned to each procedure to extract DRLs. To estimate effective dose, conversion factors and DAP values were used for seven IR procedures. DRL values for DAP were 141, 130 and 28 Gy*cm2 for HC, ISP, and FR, respectively. The corresponding DRL values for Ka,r were 634.6, 300.1 and 112.0 mGy, and for FT were 15.3, 12.4 and 17.9 min, respectively. CIs in interventional radiology are a useful tool for the optimisation of DRLs since they contribute to patient's doses.


Assuntos
Níveis de Referência de Diagnóstico , Radiologia Intervencionista , Humanos , Doses de Radiação , Padrões de Referência , Fluoroscopia/métodos , Radiografia Intervencionista , Valores de Referência
SELEÇÃO DE REFERÊNCIAS